26 resultados para NO stripping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solubility of manganese in mercury was determined electrochemically via amalgamation and stripping in the room temperature ionic liquid n-hexyltriethylammonium bis(trifluoromethanesulfonyl)imide, [N-6,N-2,N-2,N-2][NTf2]. A hemispherical mercury electrode was made by electrodepositing mercury onto a planar platinum microelectrode. Cyclic voltammetry of Mn2+ in [N-6,N-2,N-2,N-2][NTf2] at the mercury microhemisphere electrode was investigated at temperatures of 298, 303 and 313 K. The solubility of Mn in Hg was determined on the basis of the charge under the reduction peak (Mn2+ --> Mn-0) and the corresponding reoxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline TiO2 deposited on conducting glass plates is shown to be an excellent material for preconcentration of silver and mercury, via photochemical reaction, prior to their detection by anodic stripping voltammetry (ASV). During the first stage of growth in the photoreduction of silver or mercury, 3D nuclei are formed on the TiO2 film. As the deposition proceeds micrometer size agglomerates grow on the surface. The conical morphology of the silver nuclei grown on a (110) rutile single crystal in the initial stages of growth suggests that there is a preferential deposition of silver at the centre of the growing nuclei. When the nuclei size reach a critical value (ca. 400 nm diameter, 40 nm height) the morphology changes to a globular shape without any preferential site for deposition on the surface of the silver nucleus. It was observed that micromolar concentrations of silver or mercury can be detected by anodic stripping voltammetry and relatively large amounts of these metals (micrometer scale nuclei) can be loaded on the nanocrystalline TiO2 film surface. The latter opens the possibility of analytical applications of nanocrystalline TiO2 electrodes for the selective detection of silver or mercury via photochemical anodic stripping voltammetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrodeposition of metals onto conductive supports such as graphite potentially provides a lower-waste method to form heterogeneous catalysts than the standard methods such as wet impregnation. Copper electrodeposition onto pressed graphite disc electrodes was investigated from aqueous CuSO4-ethylenediamine solutions by chronoamperometry with scanning electron microscopy used to ascertain the particle sizes obtained by this method. The particle size was studied as a function of pH, CuSO4-ethylenediamine concentration, and electrodeposition time. It was observed that decreasing the pH, copper-ethylenediamine concentration and time each decreased the size of the copper particles observed, with the smallest obtained being around 5-20 nm. Furthermore, electroless aerobic oxidation of copper metal in the presence of ethylenediamine was successfully coupled with the electrodeposition in the same vessel. In this way, deposition was achieved sequentially on up to twenty different graphite discs using the same ethylenediamine solution, demonstrating the recyclability of the ligand. The materials thus prepared were shown to be catalytically active for the mineralisation of phenol by hydrogen peroxide. Overall, the results provide a proof-of-principle that by making use of aerobic oxidation coupled with electrochemical deposition, elemental base metals can be used directly as starting materials to form heterogeneous catalysts without the need to use metal salts as catalyst precursors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen ions (H+, H-2(+) and H-3(+)) are produced in a magnetically confined inductively coupled radio frequency plasma. Ions are accelerated in the plasma boundary sheath potential, of several hundred volts, in front of a biased metal electrode immersed in the plasma. Backscattered hyperthermal hydrogen atoms are investigated by optical emission spectroscopy and an energy-resolved mass spectrometer. Ionisation of fast neutrals through electron stripping of atoms in the plasma allows energy analysis of the resulting ions. Thereby, the energy distribution function of the hyperthermal atoms can be deduced. The energy spectra can be explained as a superposition of individual spectra of the various ion species. The measured spectra also shows contributions of negative ions created at the electrode surface. In addition to experimental measurements, simulations of the neutral flux of backscattered atoms are carried out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the first time, the electrochemistry of gold has been studied in detail in a 'second-generation', non-haloaluminate, ionic liquid. In particular, the electrochemical behaviour of Na[AuCl4] has been investigated in 1-butyl-3-methylimidazolium bis{(tifluoromethyl)sulfonyl} imide, [C(4)mim][NTf2], over gold, platinum and glassy carbon working electrodes. The reduction of [AuCl4](-) initially forms [AuCl2](-) before deposition on the electrode as Au(0). To enable stripping of deposited gold or electrodissolution of bulk gold, the presence of chloride, trichloride or chlorine is required. Specifically trichloride and chlorine have been identified as the active species which preferentially form Au(I) and Au(III), respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electroanalytical quantification of chloride in [C(4)mim][BF4], [C(4)mim][NTf2] and [C(4)mim][PF6] ionic liquids has been explored using linear sweep and square wave voltammetry. Cathodic stripping voltammetry at a silver disk electrode is found to be the most sensitive. The methodology is based on first holding the potential of the electrode at +2.0 V (vs Ag wire), to accumulate silver chloride at the electrode. On applying a cathodic scan, a stripping wave is observed corresponding to the reduction of the silver chloride. This stripping protocol was found to detect ppb levels of chloride in [C(4)mim][BF4], [C(4)mim][NTf2], and [C(4)mim][PF6]. Although other methods for chloride have been reported for [BF4](-)- and [PF6](-)-based ionic liquids, no methods have been reported for [NTf2](-) ionic liquids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of chloride impurities in water miscible and water immiscible ionic liquids has been explored using ion chromatography (IC) and cathodic stripping voltammetry (CSV). This paper shows the first quantification of chloride in [NTf2](-) based ILs. The parameters investigated include sample preparation, solvent effect, sample stability, and limit of quantification (LOQ).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical oxidation of hydrogen sulfide gas (H2S) has been studied at a platinum microelectrode (10 mu m diameter) in five room temperature ionic liquids (RTILs): [C(4)mim][OTf], [C(4)dmim][NTf2], [C(4)mim][PF6],. [C(6)mim][FAP], and [P-14,P-6,P-6,P-6][FAP] (where [C-n mim](+) = 1-alkyl-3-methylimidazolium, [C(n)dmim](+) = 1-alkyl-2,3-dimethylimidazolium, [P-14,P-6,P-6,P-6](+) = tris(p-hexyl)-tetradecylphosphonium, [OTf](-) = trifluoromethlysulfonate, [NTf2](-) = bis(trifluoromethylsulfonyl)imide, [PF6](-) = hexafluorophosphate, and [FAP](-) = trifluorotris(pentafluoroethyl)phosphate). In four of the RTILs ([C(4)dmim][NTf2], [C(4)mim][PF6], [C(6)mim][FAP], and [P-14,P-6,P-6,P-6][FAP]), no clear oxidative signal was observed. In [C(4)mim][OTf], a chemically irreversible oxidation peak was observed on the oxidative sweep with no signal seen on the reverse scan. The oxidative signal showed an adsorptive stripping peak type followed by near steady-state limiting current behavior. Potential step chronoamperometry was carried out on the reductive wave, giving a diffusion coefficient and solubility of 1.6 x 10(-11) m(2) s(-1) and 7 mM, respectively (at 25 degrees C). Using these data, we modeled the oxidation signal kinetically, assuming adsorption preceded oxidation and that adsorption was approximately Langmuirian. The oxidation step was described by an electrochemically fully irreversible Tafel law/Butler-Volmer formalism. Modeling indicated a substantial buildup of H2S in the double layer in excess of the coverage that would be expected for a monolayer of chemisorbed H2S, reflecting high solubility of the gas in [C(4)mim][OTf] and possible attractive interactions with the [OTf](-) anions accumulated at the electrode at potentials positive of the potential of zero charge. Solute enrichment of the double layer in the solution adjacent to the electrode appears a novel feature of RTIL electrochemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an extensive set of photometric and spectroscopic data for SN 2009jf, a nearby Type Ib supernova (SN), spanning from ˜20 d before B-band maximum to 1 yr after maximum. We show that SN 2009jf is a slowly evolving and energetic stripped-envelope SN and is likely from a massive progenitor (25-30 Msun). The large progenitor's mass allows us to explain the complete hydrogen plus helium stripping without invoking the presence of a binary companion. The SN occurred close to a young cluster, in a crowded environment with ongoing star formation. The spectroscopic similarity with the He-poor Type Ic SN 2007gr suggests a common progenitor for some SNe Ib and Ic. The nebular spectra of SN 2009jf are consistent with an asymmetric explosion, with an off-centre dense core. We also find evidence that He-rich Ib SNe have a rise time longer than other stripped-envelope SNe, however confirmation of this result and further observations are needed. This paper is based on observations with several telescopes, including NTT(184.D-1151), VLT-UT1(085.D-0750,386.D-0126), NOT, WHT, TNG, PROMPT, Ekar, Calar Alto and Liverpool Telescope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TiO2 coated glass shows excellent stability in the range pH 2-9, however, there is rapid and complete stripping of the TiO2 coating between pH 11 and 12.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate if the super-saturation phenomenon observed at X-ray wavelengths for the corona exists in the chromosphere for rapidly rotating late-type stars. Moderate resolution optical spectra of fast-rotating EUV- and X-ray-selected late-type stars were obtained. Stars in a Per were observed in the northern hemisphere with the Isaac Newton 2.5 m telescope and Intermediate Dispersion Spectrograph. Selected objects from IC 2391 and IC 2602 were observed in the southern hemisphere with the Blanco 4 m telescope and R-C spectrograph at CTIO. Ca II H and K fluxes were measured for all stars in our sample. We find the saturation level for Ca II K at log (L CaK/L bol) = -4.08. The Ca II K flux does not show a decrease as a function of increased rotational velocity or smaller Rossby number as observed in the X-ray. This lack of "super-saturation" supports the idea of coronal stripping as the cause of saturation and super-saturation in stellar chromospheres and coronae, but the detailed underlying mechanism is still under investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have established that some of the wear damage seen on cast CoCrMo joint surface is caused by entrained third-body hard particles. In this study, wet-cell micro-indentation and nano-scratch tests have been carried out with the direct aim of simulating wear damage induced by single abrasive particles entrained between the surfaces of cast CoCrMo hip implants. In situ electrochemical current noise measurements were uniquely performed to detect and study the wear-induced corrosion as well as the repassivation kinetics under the micro-/nano-scale tribological process. A mathematical model has been explored for the CoCrMo repassivation kinetics after surface oxide film rupture. Greater insights into the nature of the CoCrMo micro-/nano-scale wear-corrosion mechanisms and deformation processes are determined, including the identification of slip band formation, matrix/carbide deformation, nanocrystalline structure formation and strain-induced phase transformation. The electrochemical current noise provides evidence of instantaneous transient corrosion activity at the wearing surface resulting from partial oxide rupturing and stripping, concurrent with the indent/scratch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals, along with the potential use of novel taggants in environmental forensic investigations. The proposed system provides the facilities found in a traditional laboratory-based instrument but in a hand held design, without the need for an associated computer. The electrochemical instrument uses anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise a small disposable plastic strip of screen-printed electrodes rather than the more common glassy carbon disc and gold electrodes. The system is designed for use by a surveyor on site, allowing them to locate hotspots, thus avoiding the expense and time delay of prior laboratory analysis. This is particularly important in environmental forensic analysis when a site may have been released back to the owner and samples could be compromised on return visits. The system can be used in a variety of situations in environmental assessments, the data acquired from which provide a metals fingerprint suitable for input to a database. The proposed novel taggant tracers, based on narrow-band atomic fluorescence, are under development for potential deployment as forensic environmental tracers. The use of discrete fluorescent species in an environmentally stable host has been investigated to replace existing toxic, broadband molecular dye tracers. The narrow band emission signals offer the potential for tracing a large number of signals in the same environment. This will give increased data accuracy and allow multiple source environmental monitoring of environmental parameters.