42 resultados para Multilevel Inverter, Harmonic Elimination, Switching Time, Hysteresis Voltage Control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have developed the capability to determine accurate harmonic spectra for multielectron atoms within time-dependent R-matrix (TDRM) theory. Harmonic spectra can be calculated using the expectation value of the dipole length, velocity, or acceleration operator. We assess the calculation of the harmonic spectrum from He irradiated by 390-nm laser light with intensities up to 4 x 10(14) W cm(-2) using each form, including the influence of the multielectron basis used in the TDRM code. The spectra are consistent between the different forms, although the dipole acceleration calculation breaks down at lower harmonics. The results obtained from TDRM theory are compared with results from the HELIUM code, finding good quantitative agreement between the methods. We find that bases which include pseudostates give the best comparison with the HELIUM code, but models comprising only physical orbitals also produce accurate results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to develop a new generation of extruder control system for recycled materials which has ability to automatically maintain constant a polymer melt viscosity of mixed recycled polymers during extrusion, regardless of variations in the Melt Flow Index (MFI) of recycled mixed grade high density polyethylene (HDPE) feedstock. The variations in MFI are due to differences in the source of the recycled material used. The work describes how melt viscosity for specific extruder/die system is calculated in real time using the rheological properties of the materials, the pressure drop through the extruder die and the actual throughput measurements using a gravimetric loss-in-weight hopper feeder. A closed-loop controller is also developed to automatically regulate screw speed and barrel temperature profile to achieve constant viscosity and enable consistent processing of variable grade recycled HDPE materials. Such a system will improve processability of mixed MFI polymers may also reduce the risk of polymer melt degradation, reduce producing large volumes of scrap/waste and lead to improvement in product quality. The experimental results of real time viscosity measurement and control using a 38 mm single screw extruder with different recycled HDPEs with widely different MFIs are reported in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power back-off performances of the modified power-combining Class-E amplifier under different amplitudemodulation schemes such as envelope elimination and restoration (EER) and envelope tracking (ET) are experimentally assessed in this paper. The modified output load network adopting three-harmonic terminations technique eliminates the need for additional lossy filtering section in the transmitter chain. Small dc-feed inductances rather than massive RF chokes as in the classic Class-E amplifier are used so as to increase the modulation bandwidth and therefore improve the linearity of the EER transmitter. High efficiency over a wide dynamic range using amplitude modulation through drain-voltage control (EER) was achieved and this agrees well with the Class-E theoretical prediction. When the PA was used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12dB peak-to-average power ratio. © 2011 Institut fur Mikrowellen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design and characterizations of an ultrafast single-pole single-throw (SPST) absorptive differential switch are presented. The switch exhibits low insertion loss less than 1 dB, and isolation better than 16 dB from 40 to 70 GHz. Sub-nanosecond switching time is achieved by adopting a differential current-steering technique. The total measured rise and fall time are 75 ps envisaging that switching rates up to 13 Gb/s are achievable. To our best knowledge, this is the fastest, lowest insertion loss V-band SPST switch yet reported that can operate over a wide bandwidth of 30 GHz.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This output is a collection of compositions which explore issues of ensemble improvisation, ensemble management and orchestration, real-time and distributed scoring, multi-nodal inputs and outputs, and animated and graphic notation. Compositions include: Activities I; tutti, duet, trio, solo, quartet; Lewitt Notations I; Webwork I; and Sometimes I feel the space between people (voices) in terms of tempos. These compositions are presented in computer animated scores which are synchronized through the network and subject to real-time modification and control. They can be performed by ensembles distributed over large physical spaces connected by the network. The scores for these compositions include software which displays the animations to the performers, software to structure and disseminate score events, and triggering software that allows the control of a performance to be distributed. Scores can also include live electronics which are coordinated with graphic events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an ultrafast wideband low-loss single-pole double-throw (SPDT) differential switch in 0.35 µ m SiGe bipolar technology. The proposed topology adopting current-steering technique results in a total measured switching time of 75 ps , which suggests a maximum switching rate of 13 Gb/s, the fastest ever reported at V-band. In addition, the switch exhibits an insertion loss lower than 1.25 dB and an isolation higher than 18 dB from 42 GHz to 70 GHz. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design and characterization of ultrafast wideband low-loss single-pole single-throw (SPST) and single-pole double-throw (SPDT) differential switches. The SPDT switch exhibits insertion loss of lower than 1.25 dB from 42 to 70 GHz and isolation of better than 20 dB from 40 to 65 GHz. Similar low-loss and broadband characteristics are also observed from the measured SPST switch. The proposed switch topologies adopting current-steering technique and implemented in 0.35 µm SiGe bipolar technology result in a switching time of only 75 ps. This suggests a maximum switching speed of 13 Gbps, the fastest ever reported at V-band.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the ability of the doubly fed induction generator (DFIG) to deliver multiple reactive power objectives during variable wind conditions. The reactive power requirement is decomposed based on various control objectives (e.g. power factor control, voltage control, loss minimisation, and flicker mitigation) defined around different time frames (i.e. seconds, minutes, and hourly), and the control reference is generated by aggregating the individual reactive power requirement for each control strategy. A novel coordinated controller is implemented for the rotor-side converter and the grid-side converter considering their capability curves and illustrating that it can effectively utilise the aggregated DFIG reactive power capability for system performance enhancement. The performance of the multi-objective strategy is examined for a range of wind and network conditions, and it is shown that for the majority of the scenarios, more than 92% of the main control objective can be achieved while introducing the integrated flicker control scheme with the main reactive power control scheme. Therefore, optimal control coordination across the different control strategies can maximise the availability of ancillary services from DFIG-based wind farms without additional dynamic reactive power devices being installed in power networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reactive power has become a vital resource in modern electricity networks due to increased penetration of distributed generation. This paper examines the extended reactive power capability of DFIGs to improve network stability and capability to manage network voltage profile during transient faults and dynamic operating conditions. A coordinated reactive power controller is designed by considering the reactive power capabilities of the rotor-side converter (RSC) and the grid-side converter (GSC) of the DFIG in order to maximise the reactive power support from DFIGs. The study has illustrated that, a significant reactive power contribution can be obtained from partially loaded DFIG wind farms for stability enhancement by using the proposed capability curve based reactive power controller; hence DFIG wind farms can function as vital dynamic reactive power resources for power utilities without commissioning additional dynamic reactive power devices. Several network adaptive droop control schemes are also proposed for network voltage management and their performance has been investigated during variable wind conditions. Furthermore, the influence of reactive power capability on network adaptive droop control strategies has been investigated and it has also been shown that enhanced reactive power capability of DFIGs can substantially improve the voltage control performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. The impact of flicker propagation along the wind farm feeder and effectiveness of the proposed strategy is also evaluated with consumer loads connected to the wind farm feeder. It is shown that voltage variability and short-term flicker severity is significantly reduced following implementation of the novel strategy described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is concerned with the voltage and reactive power issues surrounding the connection of Distributed Generation (DG) on the low-voltage (LV) distribution network. The presented system-wide voltage control algorithm consists of three stages. Firstly available reactive power reserves are utilized. Then, if required, DG active power output is curtailed. Finally, curtailment of non-critical site demand is considered. The control methodology is tested on a variant of the 13-bus IEEE Node Radial Distribution Test Feeder. The presented control algorithm demonstrated that the distribution system operator (DSO) can maintain voltage levels within a desired statutory range by dispatching reactive power from DG or network devices. The practical application of the control strategy is discussed.