6 resultados para Magnetic search coil
Resumo:
Considerable controversy still exists as to whether electric and magnetic fields (MF) at extremely low frequencies are genotoxic to humans. The aim of this study was to test the ability of alternating magnetic fields to induce DNA and chromosomal damage in primary human fibroblasts. Single- and double-strand breaks were quantified using the alkaline comet assay and the gammaH2AX-foci assay, respectively. Chromosomal damage was assayed for unstable aberrations, sister chromatid exchange and micronuclei. Cells were exposed to switching fields - 5min on, 10min off - for 15h over the range 50-1000microT. Exposure to ionizing radiation was used as a positive-effect calibration. In this study two separate MF exposure systems were used. One was based on a custom-built solenoid coil system and the other on a commercial system almost identical to that used in previous studies by the EU REFLEX programme. With neither system could DNA damage or chromosomal damage be detected as a result of exposure of fibroblasts to switching MF. The sensitive gammaH2AX assay could also not detect significant DNA damage in the MF-exposed fibroblasts, although the minimum threshold for this assay was equivalent to an X-ray dose of 0.025Gy. Therefore, with comparable MF parameters employed, this study could not confirm previous studies reporting significant effects for both the alkaline and neutral comet assays and chromosomal aberration induction.
Resumo:
Magnetic bright points (MBPs) in the internetwork are among the smallest objects in the solar photosphere and appear bright against the ambient environment. An algorithm is presented that can be used for the automated detection of the MBPs in the spatial and temporal domains. The algorithm works by mapping the lanes through intensity thresholding. A compass search, combined with a study of the intensity gradient across the detected objects, allows the disentanglement of MBPs from bright pixels within the granules. Object growing is implemented to account for any pixels that might have been removed when mapping the lanes. The images are stabilized by locating long-lived objects that may have been missed due to variable light levels and seeing quality. Tests of the algorithm, employing data taken with the Swedish Solar Telescope, reveal that approximate to 90 per cent of MBPs within a 75 x 75 arcsec(2) field of view are detected.
Resumo:
The search for materials or systems exhibiting a high magnetic saturation has been of longstanding importance. It has been suggested that increased saturation could be achieved by coupling a transition metal via a spacer to a rare earth. We report Gd/Cr/Fe70Co30 multilayer stacks and find reduced yet modulating magnetic moment as a function of Cr thickness. Through a micro structural analysis the lowered moment is indicated by the nucleation of the ultrathin Gd films into an fcc phase. We discuss the possible solution in terms of quasi-perfect lattice match seed material to promote growth of hcp Gd.
Resumo:
AC magnetic heating of superparamagnetic Co and Fe nanoparticles for application in hyperthermia was measured to find a size of nanoparticles that would result in an optimal heating for given amplitude and frequency of ac externally applied magnetic field. To measure it, a custom-made power supply connected to a 20-turn insulated copper coil in the shape of a spiral solenoid cooled with water was used. A fiber-optic temperature sensor has been used to measure the temperature with an accuracy of 0.0001 K. The magnetic field with magnitude of 20.6 µT and a frequency of oscillation equal to 348 kHz was generated inside the coil to heat magnetic nanoparticles. The maximum specific power loss or the highest heating rate for Co magnetic nanoparticles was achieved for nanoparticles of 8.2 nm in diameter. The maximum heating rate for coated Fe was found for nanoparticles with diameter of 18.61 nm. © (2013) Trans Tech Publications, Switzerland.
Resumo:
Objective
To determine the optimal transcranial magnetic stimulation (TMS) coil direction for inducing motor responses in the tongue in a group of non-neurologically impaired participants.
Methods
Single-pulse TMS was delivered using a figure-of-eight Magstim 2002 TMS coil. Study 1 investigated the effect of eight different TMS coil directions on the motor-evoked potentials elicited in the tongue in eight adults. Study 2 examined active motor threshold levels at optimal TMS coil direction compared to a customarily-used ventral-caudal direction. Study 3 repeated the procedure of Study 1 at five different sites across the tongue motor cortex in one adult.
Results
Inter-individual variability in optimal direction was observed, with an optimal range of directions determined for the group. Active motor threshold was reduced when a participant's own optimal TMS coil direction was used compared to the ventral-caudal direction. A restricted range of optimal directions was identified across the five cortical positions tested.
Conclusions
There is a need to identify each individual's own optimal TMS coil direction in investigating tongue motor cortex function. A recommended procedure for determining optimal coil direction is described.
Significance
Optimized TMS procedures are needed so that TMS can be utilized in determining the underlying neurophysiological basis of various motor speech disorders.
Resumo:
Context. Close-in, giant planets are expected to influence their host stars via tidal or magnetic interaction. But are these effects in X-rays strong enough in suitable targets known so far to be observed with today's instrumentation? Aims: The υ And system, an F8V star with a Hot Jupiter, was observed to undergo cyclic changes in chromospheric activity indicators with its innermost planet's period. We aim to investigate the stellar chromospheric and coronal activity over several months. Methods: We therefore monitored the star in X-rays as well as at optical wavelengths to test coronal and chromospheric activity indicators for planet-induced variability, making use of the Chandra X-ray Observatory as well as the echelle spectrographs FOCES and HRS at Calar Alto (Spain) and the Hobby-Eberly Telescope (Texas, US). Results: The stellar activity level is low, as seen both in X-rays as in Ca ii line fluxes; the chromospheric data show variability with the stellar rotation period. We do not find activity variations in X-rays or in the optical that can be traced back to the planet. Conclusions: Gaining observational evidence of star-planet interactions in X-rays remains challenging.