6 resultados para Intraoral appliance
Resumo:
This paper describes a fridge-freezer smart load model, which responds to external signals from the wholesale electricity market to support grid operations while switching the fridge-freezer on and off to maintain optimum operations for the owner. The key parameters of the model are the appliance dimensions, thermal mass, the fridge and freezer thermal time constants and the compressor power consumption. The model demonstrates that control strategies help to minimise load at times when the grid is under stress from high demand, and shift some load to a lower wholesale price or when there is excess renewable power. Three control strategies are proposed, based on peak shaving and valley filling, price signals and wind availability.
Resumo:
As a consequence of the fragility of various neural structures, preterm infants born at a low gestation and/or birthweight are at an increased risk of developing motor abnormalities. The lack of a reliable means of assessing motor integrity prevents early therapeutic intervention. In this paper, we propose a new method of assessing neonatal motor performance, namely the recording and subsequent analysis of intraoral sucking pressures generated when feeding nutritively. By measuring the infant's control of sucking in terms of a new development of tau theory, normal patterns of intraoral motor control were established for term infants. Using this same measure, the present study revealed irregularities in sucking control of preterm infants. When these findings were compared to a physiotherapist's assessment six months later, the preterm infants who sucked irregularly were found to be delayed in their motor development. Perhaps a goal-directed behaviour such as sucking control that can be measured objectively at a very young age, could be included as part of the neurological assessment of the preterm infant. More accurate classification of a preterm infant's movement abnormalities would allow for early therapeutic interventions to be realised when the infant is still acquiring the most basic of motor functions. (C) Springer-Verlag 2000.
Resumo:
Human newborns appear to regulate sucking pressure when bottle feeding by employing, with similar precision, the same principle of control evidenced by adults in skilled behavior, such as reaching (Lee et al., 1998a). In particular, the present study of 12 full-term newborn infants indicated that the intraoral sucking pressures followed an internal dynamic prototype - an intrinsic tau-guide. The intrinsic tau-guide, a recent hypothesis of general tau theory is a time-varying quantity, tau(g), assumed to be generated within the nervous system. It corresponds to some quantity (e.g., electrical charge), chang ing with a constant second-order temporal derivative from a rest level to a goal level, in the sense that tau(g) equals tau of the gap between the quantity and its goal level at each time t. (tau of a gap is the rime-to-closure of the gap at the current closure-rate.) According to the hypoth esis, the infant senses tau(p), the tau of the gap between the current intraoral pressure and its goal level, and regulates intraoral pressure so that tau(p) and tau(g) remain coupled in a constant ratio, k; i.e., tau(p) = k tau(g). With k in the range 0-1, the tau-coupling would result in a bell-shaped rate of change pressure profile, as was, in fact, found. More specifically, the high mean r(2) values obtained when regressing tau(p) on tau(g), for both the increasing and decreasing suction periods of the infants' suck, supported a strong tau-coupling between tau(p) and tau(g). The mean k values were significantly higher In the Increasing suction period, indicating that the ending of the movement was more forceful, a finding which makes sense given the different functions of the two periods of the suck.
Resumo:
Introduction: Our objective was to determine which factors were predictive of good long-term outcomes after fixed appliance treatment of Class II Division 1 malocclusion. Methods: Two hundred seven patients with Class II Division 1 malocclusion were examined in early adulthood at a mean of 4.6 years after treatment with fixed appliances. The peer assessment rating index was used to evaluate dental alignment and occlusal relationships. The soft-tissue profile was assessed with the Holdaway angle. Results: Logistic regression identified 3 pretreatment variables that were predictive of a good facial profile (Holdaway angle) at recall: the lower lip to E-plane distance (P
Resumo:
Due to the intermittent nature of renewable generation it is desirable to consider the potential of controlling the demand-side load to smooth overall system demand. The architecture and control methodologies of such a system on a large scale would require careful consideration. Some of these considerations are discussed in this paper; such as communications infrastructure, systems architecture, control methodologies and security. A domestic fridge is used in this paper as an example of a controllable appliance. A layered approach to smart-grid is introduced and it can be observed how each smart-grid component from physical cables, to the end-devices (or smart-applications) can be mapped to these set layers. It is clear how security plays an integral part in each component of the smart-grid so this is also an integral part of each layer. The controllable fridge is described in detail and as one potential smart-grid application which maps to the layered approach. A demonstration system is presented which involves a Raspberry Pi (a low-power, low-cost device representing the appliance controller).