2 resultados para Inhalation
Resumo:
Smoking is one of the leading causes of preventable death. In recent years, numerous countries have initiated the prohibition of smoking in restaurants, workplaces and public spaces. The Vietnamese government intends to follow the precautions against public smoking as well. Over and above the number of some hazardous chemical components found in tobacco, 210Po isotope content could enhance the probability of the development of lung cancer. In this study 14 Vietnamese tobacco products (commercial cigarettes and pipe tobacco) 210Po activity concentration were determined using PIPS semiconductor alpha spectrometry. The results showed that the 210Po activity concentration of the investigated samples varied between 7.40 ± 1.09 - 128.64 ± 11.22 mBq g-1. The average 210Po content of commercial cigarettes was 15.5 mBq g-1, whilst the average of pipe tobacco was 20.4 mBq g-1. To estimate the risk of inhalation of 210Po isotopes originating as a result of smoking, dose estimations were carried out. © Versita Sp. z o.o.
Resumo:
BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.
METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.
RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.
CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.