80 resultados para Impedance tube


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is discussed for measuring the acoustic impedance of tubular objects that gives accurate results for a wide range of frequencies. The apparatus that is employed is similar to that used in many previously developed methods; it consists of a cylindrical measurement duct fitted with several microphones, of which two are active in each measurement session, and a driver at one of its ends. The object under study is fitted at the other end. The impedance of the object is determined from the microphone signals obtained during excitation of the air inside the 1 duct by the driver, and from three coefficients that are pre-determined using four calibration measurements with closed cylindrical tubes. The calibration procedure is based on the simple mathematical relationships between the impedances of the calibration tubes, and does not require knowledge of the propagation constant. Measurements with a cylindrical tube yield an estimate of the attenuation constant for plane waves, which is found to differ from the theoretical prediction by less than 1.4% in the frequency range 1 kHz-20 kHz. Impedance measurements of objects with abrupt changes in diameter are found to be in good agreement with multimodal theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficacy of gentamicin, nebulised via the endotracheal tube (ET), with that of parenteral cefotaxime or parenteral cefuroxime in preventing the formation of ET biofilm.

Setting: General intensive care units in two university teaching hospitals.

Design: The microbiology of ET biofilm from 36 ICU patients eligible to receive antibiotic prophylaxis was examined. Peak and trough tracheal concentrations of gentamicin, cefotaxime or cefuroxime were measured in each patient group, on the 2nd day of intubation.

Patients: Twelve patients received gentamicin (80 mg) nebulised in 4 ml normal saline every 8 h, 12 cefotaxime (1 g, 12 hourly) and 12 cefuroxime (750 mg, 8 hourly). Prophylaxis was continued for the duration of intubation.

Measurements and results: Samples of tracheal secretions were taken on the 2nd day of ventilation for determination of antibiotic concentrations. Following extubation, ETs were examined for the presence of biofilm. Pathogens considered to be common aetiological agents for VAP included Staphylococcus aureus, enterococci, Enterobacteriaceae and pseudomonads. While microbial biofilm was found on all ETs from the cephalosporin group, microbial biofilm of these micro-organisms was found on 7 of the 12 ET tubes from patients receiving cefotaxime [S. aureus (4), pseudomonads (1), Enterobacteriaceae (1), enterococcus (1)] and 8 of the 12 ET tubes from patients receiving cefuroxime [Enterobacteriaceae (6), P. aeruginosa (1) and enterococcus (1)]. While microbial biofilm was observed on five ETs from patients receiving nebulised gentamicin, none of these were from pathogens for ventilator-associated pneumonia (VAP). Tracheal concentrations of both cephalosporins were lower than those needed to inhibit the growth of pathogens recovered from ET tube biofilm. The median (and range) concentrations for cefotaxime were 0.90 (<0.23–1.31) mg/l and 0.28 (<0.23–0.58) mg/l for 2 h post-dose and trough samples, respectively. Two hours post-dose concentrations of cefuroxime (median and range) were 0.40 (0.34–0.83) mg/l, with trough concentrations of 0.35 (<0.22–0.47) mg/l. Tracheal concentrations (median and range) of gentamicin measured 1 h post-nebulisation were 790 (352–>1250) mg/l and then, before the next dose, were 436 (250–1000) mg/l.

Conclusion: Nebulised gentamicin attained high concentrations in the ET lumen and was more effective in preventing the formation of biofilm than either parenterally administered cephalosporin and therefore may be effective in preventing this complication of mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The safety and maximum tolerated dose (MTD) of erlotinib with docetaxel/carboplatin were assessed in patients with ovarian cancer. Chemonaive patients received intravenous docetaxel (75 mg m(-2)) and carboplatin (area under the curve 5) on day 1 of a 3-week cycle, and oral erlotinib at 50 (cohort 1), 100 (cohort 2a) or 75 mg day(-1) (cohort 2b) for up to six cycles. Dose-limiting toxicities were determined in cycle 1. Forty-five patients (median age 59 years) received treatment. Dose-limiting toxicities occurred in 1/5/5 patients (cohorts 1/2a/2b). The MTD of erlotinib in this regimen was determined to be 75 mg day(-1) (cohort 2b; the erlotinib dose was escalated to 100 mg day(-1) in 11 out of 19 patients from cycle 2 onwards). Neutropaenia was the predominant grade 3/4 haematological toxicity (85/100/95% respectively). Common non-haematological toxicities were diarrhoea, fatigue, nausea and rash. There were five complete and seven partial responses in 23 evaluable patients (52% response rate). Docetaxel/carboplatin had no measurable effect on erlotinib pharmacokinetics. In subsequent single-agent maintenance, erlotinib was given at 100-150 mg day(-1), with manageable toxicity, until tumour progression. Further investigation of erlotinib in epithelial ovarian carcinoma may be warranted, particularly as maintenance therapy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new circuit-model approach which can be used to compute the mutual impedance between two dipoles fed at the same feed point. The validity of the method is confirmed by comparison with mutual impedance values obtained when the dipoles are individually excited and orientated at angles between 0degrees and 90degrees. (C) 2004 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimidazolium. trifluoromethylsulfonate ([C(4)mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C(4)mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of similar to 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of root(rho eta) approximate to 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The H+NO2 titration scheme for the determination of atomic hydrogen densities within a microwave excited flow tube reactor has been investigated by laser-induced fluorescence spectroscopy in the vacuum UV. Absolute hydrogen densities are determined on the basis of calibration by Rayleigh scattering from argon. The measurement is performed at a gas mixture containing 0.5% of D2 added to the main gas H2. The ground state density of the hydrogen atoms generated in the flow tube reactor was inferred from the fluorescence radiation of the spectrally shifted optically thin D-Lyman-a transition.