16 resultados para Humphrey, Alecia
Resumo:
This article describes a step-wise approach for the understanding and interpretation of Humphrey's SITA visual field tests. The goal of this article is to help the reader to differentiate between non-specific abnormalities of the visual field and changes of the visual field that are suggestive of glaucoma.
Resumo:
PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.
Resumo:
A substantial amount of the 'critical mass' of digital data available to scholarship contains place-names, and it is now recognised that spatial and temporal data points, including place-names, are a vital part of the e-research infrastructure that supports the use, re-use and advanced analysis of data using ICT tools and methods. Place-names can also be linked semantically to contribute to the web of data, and to enrich content through linking existing data, and identifying new collections for digitization to strategically enhance existing digital collections. However, existing e-projects rely on modern gazetteers limiting them to the modern and the near-contemporary. This workshop explored how to further integrate the wealth of historical place-name scholarship, and the resulting digital resources generated within UK academia, so enabling integration of local knowledge over much longer periods.
Resumo:
Purpose: The authors estimated the retinal nerve fiber layer height (RNFLH) measurements in patients with glaucoma compared with those in age-matched healthy subjects as obtained by the laser scanning tomography and assessed the relationship between RNFLH measurements and optic and visual field status. Methods: Parameters of optic nerve head topography and RNFLH were evaluated in 125 eyes of 21 healthy subjects and 104 patients with glaucoma using the Heidelberg Retina Tomograph ([HRT] Heidelberg Engineering GmbH, Heidelberg, Germany) for the entire disc area and for the superior 70°(50°temporal and 20°nasal to the vertical midline) and inferior 70°sectors of the optic disc. The mean deviation of the visual field, as determined by the Humphrey program 24-2 (Humphrey Instruments, Inc., San Leonardo, CA, U.S.A) was calculated in the entire field and in the superior and inferior Bjerrum area. Result: Retinal nerve fiber layer height parameters (mean RNFLH and RNFL cross-sectional area) were decreased significantly in patients with glaucoma compared with healthy individuals. Retinal nerve fiber layer height parameters was correlated strongly with rim volume, rim area, and cup/disc area ratio. Of the various topography measures, retinal nerve fiber layer (RNFL) parameters and cup/disc area ratio showed the strongest correlation with visual field mean deviation in patients with glaucoma. Conclusion: Retinal nerve fiber layer height measures were reduced substantially in patients with glaucoma compared with age-matched healthy subjects. Retinal nerve fiber layer height was correlated strongly with topographic optic disc parameters and visual field changes in patients with glaucoma.
Resumo:
Purpose: To compare two fast threshold strategies of visual field assessment; SITA Fast (HSF) and Tendency Orientated Perimetry (TOP), in detecting visual field loss in patients with glaucoma. Methods: Seventy-six glaucoma, ocular hypertensive and normal patients had HSF and TOP performed in random order. Quantitative comparisons for the global visual field indices - mean deviation and defect (MD) for HSF and TOP, and pattern standard deviation (PSD) for HSF and loss variance (LV) for TOP - were made using correlation coefficients. Humphrey global parameters were converted to Octopus equivalents, and method comparison analysis was used to determine agreement between the two strategies. Test duration times were compared using t-test. Sensitivity and specificity for these two algorithms were determined according to predetermined criteria. Results: High correlation coefficient values were obtained for MD measurements between HSF and TOP (r=-0.89, P
Resumo:
Aims. To examine the antioxidant and anti-inflammatory effects of pomegranate polyphenols in obese patients with type 2 diabetes (T2DM) (n = 8) and in healthy nondiabetic controls (n = 9). Methods. Participants received 2 capsules of pomegranate polyphenols (POMx, 1 capsule = 753?mg polyphenols) daily for 4 weeks. Blood draws and anthropometrics were performed at baseline and at 4 weeks of the study. Results. Pomegranate polyphenols in healthy controls and in T2DM patients did not significantly affect body weight and blood pressure, glucose and lipids. Among clinical safety profiles, serum electrolytes, renal function tests, and hematological profiles were not significantly affected by POMx supplementation. However, aspartate aminotransferase (AST) showed a significant increase in healthy controls, while alanine aminotransferase (ALT) was significantly decreased in T2DM patients at 4 weeks (P <0.05), though values remained within the normal ranges. Among the biomarkers of lipid oxidation and inflammation, oxidized LDL and serum C-reactive protein (CRP) did not differ at 4 weeks in either group, while pomegranate polyphenols significantly decreased malondialdehyde (MDA) and hydroxynonenal (HNE) only in the diabetic group versus baseline (P <0.05). Conclusions. POMx reduces lipid peroxidation in patients with T2DM, but with no effects in healthy controls, and specifically modulates liver enzymes in diabetic and nondiabetic subjects. Larger clinical trials are merited.
Resumo:
The energy transfer by stimulated Brillouin backscatter from a long pump pulse (15 ps) to a short seed pulse (1 ps)has been investigated in a proof-of-principle demonstration experiment. The two pulses were both amplified in differentbeamlines of a Nd:glass laser system, had a central wavelength of 1054 nm and a spectral bandwidth of 2 nm, and crossedeach other in an underdense plasma in a counter-propagating geometry, off-set by 10◦. It is shown that the energy transferand the wavelength of the generated Brillouin peak depend on the plasma density, the intensity of the laser pulses, and thecompetition between two-plasmon decay and stimulated Raman scatter instabilities. The highest obtained energy transferfrom pump to probe pulse is 2.5%, at a plasma density of 0.17ncr, and this energy transfer increases significantly withplasma density. Therefore, our results suggest that much higher efficiencies can be obtained when higher densities (above0.25ncr) are used.
Resumo:
A 94 GHz waveguide Rotman lens is described which can be used to implement an amplitude comparison monopulse RADAR. In transmit mode, adjacent dual beam ports are excited with equal amplitude and phase to form a sum radiation pattern, and in receive mode, the outputs of the beam port pairs are combined using magic tees to provide a sum and a difference signal which can be used to calculate an angular error estimate for target acquisition and tracking. This approach provides an amplitude comparison monopulse system which can be scanned in azimuth and which has a low component count, with no requirement for phase shift circuitry in the array feed lines, making it suitable for mm-wave frequencies. A 12 input (beam ports), 12 output (array ports) lens is designed using CST Microwave Studio, and the predicted results are presented.
Resumo:
A prototype scotopic sensitivity machine was used to evaluate pupillary and visual thresholds for 295 Indonesian children aged 1-5 y, most of whom were initially vitamin A-deficient. Subjects were tested 6 and 9 mo after receiving a high dose of vitamin A. A group of 136 older children was tested at 6 mo after dosing; all subjects underwent testing at 9 mo. After testing at 9 mo, children randomly received either a second high dose of vitamin A or placebo and were tested a final time 2 wk later. Children with abnormal pupillary thresholds had significantly higher relative dose responses (RDRs) (P < 0.01) and significantly lower serum retinol values (P = 0.05) than did normal children. The mean pupillary threshold rose (eg, retinal sensitivity fell) as vitamin A status deteriorated between 6 and 9 mo after initial dosing, and was significantly different from a group of normal American children tested previously (P < 0.001). After placebo-controlled dosing, the decline in pupillary and visual thresholds (rise in retinal sensitivity) was significant for children receiving vitamin A but not for children receiving placebo.
Resumo:
OBJECTIVES:
To compare methods to estimate the incidence of visual field progression used by 3 large randomized trials of glaucoma treatment by applying these methods to a common data set of annually obtained visual field measurements of patients with glaucoma followed up for an average of 6 years.
METHODS:
The methods used by the Advanced Glaucoma Intervention Study (AGIS), the Collaborative Initial Glaucoma Treatment Study (CIGTS), and the Early Manifest Glaucoma Treatment study (EMGT) were applied to 67 eyes of 56 patients with glaucoma enrolled in a 10-year natural history study of glaucoma using Program 30-2 of the Humphrey Field Analyzer (Humphrey Instruments, San Leandro, Calif). The incidence of apparent visual field progression was estimated for each method. Extent of agreement between the methods was calculated, and time to apparent progression was compared.
RESULTS:
The proportion of patients progressing was 11%, 22%, and 23% with AGIS, CIGTS, and EMGT methods, respectively. Clinical assessment identified 23% of patients who progressed, but only half of these were also identified by CIGTS or EMGT methods. The CIGTS and the EMGT had comparable incidence rates, but only half of those identified by 1 method were also identified by the other.
CONCLUSIONS:
The EMGT and CIGTS methods produced rates of apparent progression that were twice those of the AGIS method. Although EMGT, CIGTS, and clinical assessment rates were comparable, they did not identify the same patients as having had field progression.
Resumo:
BACKGROUND: Impaired dark adaptation occurs commonly in vitamin A deficiency. OBJECTIVE: We sought to examine the responsiveness of dark-adaptation threshold to vitamin A and beta-carotene supplementation in Nepali women. DESIGN: The dark-adapted pupillary response was tested in 298 pregnant women aged 15-45 y in a placebo-controlled trial of vitamin A and beta-carotene; 131 of these women were also tested at 3 mo postpartum. Results were compared with those for 100 nonpregnant US women of similar age. The amount of light required for pupillary constriction was recorded after bleaching and dark adaptation. RESULTS: Pregnant women receiving vitamin A had better dark-adaptation thresholds (-1.24 log cd/m(2)) than did those receiving placebo (-1.11 log cd/m(2); P: = 0. 03) or beta-carotene (-1.13 log cd/m(2); P: = 0.05) (t tests with Bonferroni correction). Dark-adaptation threshold was associated with serum retinol concentration in pregnant women receiving placebo (P: = 0.001) and in those receiving beta-carotene (P: = 0.003) but not in those receiving vitamin A. Among women receiving placebo, mean dark-adaptation thresholds were better during the first trimester (-1.23 log cd/m(2)) than during the second and third trimesters (-1.03 log cd/m(2); P: = 0.02, t test). The mean threshold of nonpregnant US women (-1.35 log cd/m(2)) was better than that of all 3 Nepali groups (P: < 0.001, t test, for all 3 groups). CONCLUSIONS: During pregnancy, pupillary dark adaptation was strongly associated with serum retinol concentration and improved significantly in response to vitamin A supplementation. This noninvasive testing technique is a valid indicator of population vitamin A status in women of reproductive age.