26 resultados para Glasses In


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the effect of provision of free glasses on academic performance in rural Chinese children with myopia. Design: Cluster randomized, investigator masked, controlled trial.Setting 252 primary schools in two prefectures in western China, 2012-13. Participants: 3177 of 19 934 children in fourth and fifth grades (mean age 10.5 years) with visual acuity <6/12 in either eye without glasses correctable to >6/12 with glasses. 3052 (96.0%) completed the study.Interventions Children were randomized by school (84 schools per arm) to one of three interventions at the beginning of the school year: prescription for glasses only (control group), vouchers for free glasses at a local facility, or free glasses provided in class. Main outcome measures: Spectacle wear at endline examination and end of year score on a specially designed mathematics test, adjusted for baseline score and expressed in standard deviations. Results: Among 3177 eligible children, 1036 (32.6%) were randomized to control, 988 (31.1%) to vouchers, and 1153 (36.3%) to free glasses in class. All eligible children would benefit from glasses, but only 15% wore them at baseline. At closeout glasses wear was 41% (observed) and 68% (self reported) in the free glasses group, and 26% (observed) and 37% (self reported) in the controls. Effect on test score was 0.11 SD (95% confidence interval 0.01 to 0.21) when the free glasses group was compared with the control group. The adjusted effect of providing free glasses (0.10, 0.002 to 0.19) was greater than parental education (0.03, −0.04 to 0.09) or family wealth (0.01, −0.06 to 0.08). This difference between groups was significant, but was smaller than the prespecified 0.20 SD difference that the study was powered to detect. Conclusions: The provision of free glasses to Chinese children with myopia improves children’s performance on mathematics testing to a statistically significant degree, despite imperfect compliance, although the observed difference between groups was smaller than the study was originally designed to detect. Myopia is common and rarely corrected in this setting. Trial Registration: Current Controlled Trials ISRCTN03252665.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To study the effect of free glasses combined with teacher incentives on in-school glasses wear among Chinese urban migrant children. Design: Cluster-randomized controlled trial. Methods: Children with VA <= 6/12 in either eye due to refractive error in 94 randomly-chosen primary schools underwent randomization by school to receive free glasses, education on their use and a teacher incentive (Intervention), or glasses prescriptions only (Control). Intervention group teachers received a tablet computer if >= 80% of children given glasses wore them during un-announced visits 6 weeks and 6 months (main outcome) after intervention. Results: Among 4376 children, 728 (16.7%, mean age 10.9 years, 51.0% boys) met enrollment criteria and were randomly allocated, 358 (49.2%, 47 schools) to Intervention and 370 (50.8%, 47 schools) to Control. Among these, 693 children (95.2%) completed the study and underwent analysis. Spectacle wear was significantly higher at 6 months among Intervention children (Observed [main outcome]: 68.3% versus 23.9%, Adjusted Odds Ratio [OR]=11.5, 95% Confidence Interval [CI] 5.91-22.5, P<0.001; Self-reported: 90.6% versus 32.1%, OR = 43.7, 95% CI = 21.7-88.5, P < 0.001). Other predictors of observed wear at 6 months included baseline spectacle wear (P<0.001), uncorrected VA<6/18 (P=0.01) and parental spectacle wear (P=0.02). The 6-month observed wear rate was only 41% among similar-aged children provided free glasses in our previous trial without teacher incentives. Conclusions: Free spectacles and teacher incentives maintain classroom wear in the large majority of children needing glasses over a school year. Low wear among Control children demonstrates the need for interventions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To assess determinants of spectacle acceptance and use among rural Chinese children. METHODS: Children with uncorrected acuity < or = 6/12 in either eye and whose presenting vision could be improved > or = 2 lines with refraction were identified from a school-based sample of 1892 students. Information on obtaining glasses and the benefits of spectacles was provided to children, families, and teachers. Purchase of new spectacles and reasons for nonpurchase were assessed by direct inspection and interview 3 months later. RESULTS: Among 674 (35.6%) children requiring spectacles (mean age, 14.7 +/- 0.8 years), 597 (88.6%) were followed up. Among 339 children with no glasses at baseline, 30.7% purchased spectacles, whereas 43.2% of 258 children with inaccurate glasses replaced them. Most (70%) subjects paid US$13 to $26. Among children with bilateral vision < or = 6/18, 45.6% bought glasses. In multivariate models, presenting vision < 6/12 (P < 0.009), refractive error < -2.0 D (P < 0.001), and amount willing to pay for glasses (P = 0.01) were predictors of purchase. Reasons for nonpurchase included satisfaction with current vision (78% of those with glasses at baseline, 49% of those without), concerns over price or parental refusal (18%), and fear glasses would weaken the eyes (13%). Only 26% of children stated that they usually wore their new glasses. CONCLUSIONS: Many families in rural China will pay for glasses, though spectacle acceptance was < 50%, even among children with poor vision. Acceptance could be improved by price reduction, education showing that glasses will not harm the eyes, and parent-focused interventions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To study safety of children’s glasses in rural China, where fear that glasses harm vision is an important barrier for families and policy-makers. Design: Exploratory analysis from a cluster-randomized, investigator-masked, controlled trial.Methods: Among primary schools (n=252) in western China, children were randomized by school to one of three interventions: free glasses provided in class, vouchers for free glasses at a local facility or glasses prescriptions only (Control group). The main outcome of this analysis is uncorrected visual acuity after 8 months, adjusted for baseline acuity.Results: Among 19,934 children randomly selected for screening, 5852 myopic (spherical equivalent refractive error <= -0.5 D) eyes of 3001 children (14.7%, mean age 10.5 years) had VA <= 6/12 without glasses correctable to > 6/12 with glasses, and were eligible. Among these, 1903 (32.5%), 1798 (30.7%), and 2151 (36.8%) were randomized to Control, Voucher and Free Glasses respectively. Intention-to-treat analyses were performed on all 1831 (96.2%), 1699 (94.5%), and 2007 (93.3%) eyes of children with follow-up in Control, Voucher and Free Glasses groups. Final visual acuity for eyes of children in the treatment groups (Free Glasses and Voucher) was significantly better than for Control children, adjusting only for baseline visual acuity (difference of 0.023 logMAR units [0.23 vision chart lines, 95% CI: 0.03, 0.43]) or for other baseline factors as well (0.025 logMAR units [0.25 lines, 95% CI 0.04, 0.45]). Conclusion: We found no evidence that spectacles promote decline in uncorrected vision with aging among children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE:

To use focus groups to understand barriers to glasses use among children in rural China.

METHODS:

Separate focus groups were conducted between December 17, 2007, and August 5, 2008, for the following 3 groups at each of 3 schools in rural China: children aged 14 to 18 years with myopia of less than -0.5 diopters in both eyes, those children's parents, and those children's teachers. Participants were also asked to rank their responses to questions about glasses use. The focus group transcripts were coded independently by 2 investigators using qualitative data management software.

RESULTS:

Respondents of all 3 types indicated that glasses purchase and wear should be delayed in children with early myopia and might be harmful to the eyes. Parents and students reported being uncertain about children's actual myopia status and whether glasses should be worn. Parents ranked their most common reason for not buying glasses as being "too busy with work," whereas "too expensive" ranked low. Inconvenience was ranked as an important reason for not wearing glasses among all 3 student groups. "Accuracy of lens power" was the first-ranked requirement for glasses among all student groups, whereas "new and attractive styles" was ranked last by all. All 3 types of respondents believed that wearing glasses or failing to wear them might worsen myopia.

CONCLUSIONS:

Educational programs are needed to address significant knowledge gaps in families and schools about glasses use in rural China. Cost and the need for attractive styles may not be significant barriers to use in this setting, raising the possibility of paying for such programs through cost recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-eight novel salts with tetramethyl-, tetraethyl-, and tetrabutylammonium and 1-butyl-3-methylimidazolium cations paired with 3,5-dinitro-1,2,4-triazolate, 4-nitro-1,2,3-triazolate, 2,4-dinitroimidazolate, 4,5-dinitroimidazolate, 4,5-dicyanoimidazolate, 4-nitroimidazolate, and tetrazolate anions have been prepared and characterized by using differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and single-crystal Xray crystallography. The effects of cation and anion type and structure on the physicochemical properties of the resulting salts, including several ionic liquids, have been examined and discussed. Ionic liquids (defined as having m.p. <100 degrees C) were obtained with all combinations of the 1-butyl-3-methylimidazolium cation ([C(4)mim](+)) and the heterocyclic azolate anions studied, and with several combinations of tetraethyl or tetrabutylammonium cations and the azolate anions. The [C(4)mim](+) azolates were liquid at room temperature exhibiting large liquid ranges and forming glasses on cooling with glasstransition temperatures in the range of -53 to -82 degrees C (except for the 3,5-dinitro-1,2,4-triazolate salt with m.p. 33 degrees C). Six crystal structures of the corresponding tetraalkylammonium salts were determined and the effects of changes to the cations and anions on the packing of the structure have been investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The solubility and uniform distribution of lanthanide complexes in sol-get glasses can be improved by covalently linking the complexes to the sol-gel matrix. In this study, several lanthanide beta-diketonate complexes (Ln = Nd, Sm, Eu, Tb, Er, Yb) were immobilized on a 1,10-phenanthroline functionalized sol-gel glass. For the europium(Ill) complex, a sol-gel material of diethoxydimethylsilane (DEDMS) with polymer-like properties was derived. For the other lanthanide complexes, the sol-gel glass was prepared by using a matrix of tetramethoxysilane (TMOS) and DEDMS. Both systems were prepared under neutral reaction conditions. High-resolution emission and excitation spectra were recorded. The luminescence lifetimes were measured. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A controlled-atmosphere chamber, combined with a CCTV system, is used to monitor continuously the change in shape of water droplets on the self-cleaning commercial glass, Activ, and a sol-gel TiO2 substrate during their irradiation with either UVA or UVC light. This system allows the photoinduced superhydrophilic effect (PSH) exhibited by these materials to be studied in real time under a variety of different conditions. UVA was less effective than UVC in terms of PSH for both titania-coated glasses, and plain glass was unaffected by either form of UV irradiation and so showed no PSH activity. With UVA, ozone increased significantly the rate of PSH for both substrates, but had no effect on the wettability of plain glass. For both titania substrates and plain glass, no PSH activity was observed under an O-2-free atmosphere. A more detailed study of the PSH effect exhibited by Activ revealed that doping the water droplet with either an electron acceptor (Na2S2O8), electron donor (Na2S2O4), or simple electrolyte (KCl) in the absence of oxygen did not promote PSH. However, when Activ was UV irradiated, while immersed in a deoxygenated KCl solution, prior to testing for PSH activity, only a small change in contact angle was observed, whereas under the same conditions, but using a deoxygenated persulfate-containing immersion solution, it was rendered superhydrophilic. The correlation between organic contaminant removal and surface wetting was also investigated by using thick sol-gel films coated with stearic acid; the destruction of SA was monitored by FTIR and sudden wetting of the surface was seen to coincide with the substantial removal of the organic layer. The results of this work are discussed in the context of the current debate on the underlying cause of PSH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fluid immobile High Field Strength Elements (HFSE) Nb and Ta can be used to distinguish between the effects of variable extents of melting and prior source depletion of the Tongan sub-arc mantle. Melting of spinel Iherzolite beneath the Lau Basin back-arc spreading centres has the ability to fractionate Nb from Ta due to the greater compatibility of the latter in clinopyroxene. The identified spatial variation in plate velocities and separation of melt extraction zones, combined with extremely depleted lavas make Tonga an ideal setting in which to test models for arc melt generation and the role of back-arc magmatism. We present new data acquired by laser ablation-ICPMS of fused sample glasses produced without the use of a melt fluxing agent. The results show an arc trend towards strongly sub-chondritic Nb/Ta (

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Fonualei Spreading Center affords an excellent opportunity to evaluate geochemical changes with increasing depth to the slab in the Lau back-arc basin. We present H2O and CO2 concentrations and Sr, Nd, Pb, Hf and U-Th-Ra isotope data for selected glasses as well as new Hf isotope data from boninites and seamounts to the north of the Tonga arc. The Pb and Hf isotope data are used to show that mantle flow is oriented to the southwest and that the tear in the northern end of the slab may not extend east as far as the boninite locality. Along the Fonualei Spreading Center, key geochemical parameters change smoothly with increasing distance from the arc front and increasing slab surface temperatures. The latter may range from 720 to 866 degrees C, based on decreasing H2O/Ce ratios. Consistent with experimental data, the geochemical trends are interpreted to reflect changes in the amount and composition of wet pelite melts or super-critical fluids and aqueous fluids derived from the slab. With one exception, all of the lavas preserve both U-238 excesses and Ra-226 excesses. We suggest that lavas from the Fonualei Spreading Center and Valu Fa Ridge are dominated by fluid-fluxed melting whereas those from the East and Central Lau Spreading Centers, where slab surface temperatures exceed similar to 850-900 degrees C, are largely derived through decompression. A similar observation is found for the Manus and East Scotia back-arc basins and may reflect the expiry of a key phase such as lawsonite in the subducted basaltic crust.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS AND OBJECTIVES: This cross sectional descriptive study was designed to survey patient opinion towards dental clinical attire, name badges and commonly used cross-infection control measures.

METHOD: Patients attending a dental hospital for a consultation appointment were asked to complete a questionnaire accompanied by photographs of models portraying a range of clinical attire. A representative sample of patients completed 188 questionnaires over a four week period.

RESULTS: The study found that the majority of patients felt clinical attire was important and that they preferred dental professionals to wear name badges. The majority of patients also preferred dentists to use both safety glasses and face masks. When asked to indicate which clinical attire was most appropriate for a consultant/specialist to wear, the overwhelming opinion was that of smart dress accompanied with a white coat. In addition, most respondents wished their dentist to wear a traditional white, dental tunic.

CONCLUDING REMARKS: It is hoped that this study will be informative for the dental team and that the results will be taken into consideration when considering appropriate clinical attire in accordance with patient opinions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High temperature ceramic membranes have interesting possibilities for application in areas of new and developing technologies such as hydrocarbon combustion with carbon dioxide capture and electrochemical promotion of catalysis (EPOC). However, membrane module sealing remains a significant technical challenge. In this work a borosilicate glass sealant (50SiO2·25B2O3·25Na2O, mol%) was developed to fit the requirements of sealing an air separation membrane system at intermediate temperatures (300-600 °C). The seal was assessed by testing the leak rates under a range of conditions. The parameters tested included the effect of flowrate on the leak rate, the heating and cooling rates of the reactor and the range of temperatures under which the system could operate. Tests for durability and reliability were also performed. It was found that the most favourable reactor configuration employed a reactor with the ceramic pellet placed underneath the inner chamber alumina tube (inverted configuration), using a quartz wool support to keep the membrane in place prior to sealing. Using this configuration the new glass-based seal was found to be a more suitable sealant than traditional alternatives; it produced lower leak rates at all desirable flowrates, with the potential for rapid heating and cooling and multiple cycling, allowing for prolonged usage. © 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.