6 resultados para Experimental Glaucoma
Resumo:
Glaucoma is a leading cause of blindness. It is a multifactorial condition, the risk factors for which are increasingly well defined from large-scale epidemiological studies. One risk factor that remains controversial is the presence of diabetes. It has been proposed that diabetic eyes are at greater risk of injury from external stressors, such as elevated intraocular pressure. Alternatively, diabetes may cause ganglion cell loss, which becomes additive to a glaucomatous ganglion cell injury. Several clinical trials have considered whether a link exists between diabetes and glaucoma. In this review, we outline these studies and consider the causes for their lack of concordant findings. We also review the biochemical and cellular similarities between the two conditions. Moreover, we review the available literature that attempts to answer the question of whether the presence of diabetes increases the risk of developing glaucoma. At present, laboratory studies provide robust evidence for an association between diabetes and glaucoma.
Resumo:
BACKGROUND: To investigate the visual outcome of glaucoma patients.
DESIGN: This is a retrospective study of case notes of patients who died while under follow up in a glaucoma clinic of a University Hospital in Scotland between 2006 and 2009.
PARTICIPANTS: Seventy-seven patients were identified.
METHODS: Data collected included type of glaucoma, coexisting pathology and best-corrected visual acuity in Snellen (converted to decimal values) for the first and final clinic visit. The final visual status was evaluated based on the best-corrected visual acuity of the better seeing eye at the last glaucoma clinic visit. Patients who had best-corrected visual acuity of less than Snellen decimal 0.5 were considered not to meet the standards for driving.
MAIN OUTCOME MEASURES: Snellen decimal best-corrected visual acuity, fulfilment of driving standards, and eligibility for partial sight and blind registration at the last clinic visit.
RESULTS: The mean ages at presentation and death were 71.8 ± 10.3 years and 82.2 ± 8.7 years respectively. The mean Snellen decimal best-corrected visual acuity of the better eye at presentation was 0.78, and at the final clinic visit was 0.61. At the final clinic visit, no patients were partial sight registrable, four (5.2%) were blind registrable, and 27 (35.1%) did not fulfil UK driving criteria. Glaucoma patients with other ocular pathologies were more likely to fail UK driving criteria at presentation (P = 0.02) and at last clinic visit (P = 0.03).
CONCLUSION: The majority of glaucoma patients maintained good visual function at the end of their lifetime.
Resumo:
Purpose: The aim of this study is to describe the ocular and demographic features of Caucasian patients newly presenting with primary angle closure glaucoma and the proportion of workload it represents at a tertiary university hospital glaucoma service. Methods: A retrospective case notes review was conducted for all Caucasian patients newly diagnosed with narrow angles, primary angle closure, acute primary angle closure and primary angle closure glaucoma that were seen over a period of 2 years. Demographic and ocular variables were compared and statistical analysis was carried out with the paired t -test and chi-squared test. Number of primary open angle closure glaucoma and acute angle closure cases were compared with total number of new referrals to the department, new patients diagnosed with glaucoma and population numbers for the North East of Scotland. Results: One hundred and four patients were analysed. Twenty-four (23.1%) had narrow angles, 30 (28.8%) had primary angle closure and 50 (48.1%) had primary angle closure glaucoma. Twelve (11.5%) presented with acute primary angle closure. There was no significant difference for gender, age, hypermetropia or visual acuity between groups. Primary angle closure glaucoma constituted 22.9% (50/128) of newly diagnosed glaucoma cases. Based on the 2001 Scotland census, the crude annual incidence of newly diagnosed primary angle closure glaucoma was estimated at 14.8 per 100000 and 3.6 per 100000 for acute primary angle closure in the over-45-year-old population. Conclusion: Our study confirms that primary angle closure glaucoma is uncommon in Caucasians, but not as rare as originally perceived as it makes up a fair proportion (22.9%) of glaucoma workload. © 2009 The Authors Journal Compilation © 2009 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
Objective: Acquired pit-like changes of the optic nerve head (APON) are characteristic of glaucomatous damage and may be a sign of a localized susceptibility of the optic nerve. Thus, it is possible that biomechanical properties of the ocular tissues may play a pressure-independent role in the pathogenesis of glaucoma. Corneal hysteresis (CH) appears to provide information of the biomechanical properties of the ocular hull tissues. The purpose of this study was to compare CH of patients with primary open angle glaucoma (POAG) with and without APON. Methods: A prospective case control study was done. POAG patients with and without APON were measured using the Ocular Response Analyzer by masked investigators. Patients in both groups were matched for sex, age, corneal thickness, and type of glaucoma according to maximal IOP (NTG or POAG). Statistical analysis was done using ANOVA. Results: Corneal hysteresis of 16 glaucomatous eyes with APON and 32 controls (glaucoma without APON) was measured. The mean (±SD) CH in the APON group was 8.89 (±1.53) and 10.2 (±1.05) in the control group. The difference is statistically significant (p = 0.005). Conclusions: Corneal hysteresis in POAG patients with APON was significantly lower than in patients that did not have such structural changes of the optic disc. These findings may reflect pressure-independent mechanisms involved in the pathogenesis of such glaucomatous optic nerve changes. © Springer-Verlag 2007.
Resumo:
BACKGROUND: Recent National Institute of Clinical Excellence guidance suggests primary surgery should be offered to patients presenting with glaucoma with severe visual field loss. We undertook a survey of UK consultant ophthalmologists to determine if this represents current practice and explore attitudes towards managing patients with advanced glaucoma at presentation.
DESIGN: Questionnaire evaluation study.
PARTICIPANTS: All consultant ophthalmologists currently practicing in the UK.
METHODS: A single-page questionnaire was posted to all consultants (n = 910) currently practicing in the UK along with a pre-paid return envelope. A second questionnaire was sent to non-responders (n = 459).
MAIN OUTCOME MEASURES: Questionnaire responses.
RESULTS: 626 responses were received representing 68.8% of the population surveyed. 152 (24%) volunteered a specialist interest in glaucoma. Consensus opinion for both glaucoma specialists (64.9%) and non-glaucoma specialists (62.4%) was to start with primary medical therapy, most commonly citing surgical risk as the primary reason (23% and 22%, respectively) for this approach. Most felt the highest intraocular pressure measurement during follow up (measured in clinic) was the most important variable for prevention of further visual loss (60% of glaucoma specialists and 55% of non-glaucoma specialists). Eighty-three per cent of all responders suggested they would change their practice if evidence supporting primary surgery as a safe and more effective approach existed.
CONCLUSIONS: Recent National Institute of Clinical Excellence guidance does not reflect the current management approach of UK ophthalmologists. The primary concern was related to potential complications of surgery although most practitioners would be willing to change their practice if evidence existed supporting primary surgery in patients presenting with advanced glaucoma.
Resumo:
Purpose: To compare two fast threshold strategies of visual field assessment; SITA Fast (HSF) and Tendency Orientated Perimetry (TOP), in detecting visual field loss in patients with glaucoma. Methods: Seventy-six glaucoma, ocular hypertensive and normal patients had HSF and TOP performed in random order. Quantitative comparisons for the global visual field indices - mean deviation and defect (MD) for HSF and TOP, and pattern standard deviation (PSD) for HSF and loss variance (LV) for TOP - were made using correlation coefficients. Humphrey global parameters were converted to Octopus equivalents, and method comparison analysis was used to determine agreement between the two strategies. Test duration times were compared using t-test. Sensitivity and specificity for these two algorithms were determined according to predetermined criteria. Results: High correlation coefficient values were obtained for MD measurements between HSF and TOP (r=-0.89, P