12 resultados para Equipment, laryngeal mask


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Privacy region protection in video surveillance systems is an active topic at present. In previous research, a binary mask mechanism has been developed to indicate the privacy region; however this incurs a significant bitrate overhead. In this paper, an adaptive binary mask is proposed to represent the privacy region. In a practical privacy region protection application, in which the privacy region typically occupies less than half of the overall frame and is rectangular or approximately rectangular, the proposed adaptive binary mask can effectively reduce the bitrate overhead. The proposed method can also be easily applied to the FMO mechanism of H.264/AVC, providing both error resilience and a lower bitrate overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Design of Experiments (DoE) analysis was undertaken to generate a list of configurations for CFD numerical simulation of an aircraft crown compartment. Fitted regression models were built to predict the convective heat transfer coefficients of thermally sensitive dissipating elements located inside this compartment. These are namely the SEPDC and the Route G. Currently they are positioned close to the fuselage and it is of interest to optimise the heat transfer for reliability and performance purposes. Their locations and the external fuselage surface temperature were selected as input variables for the DoE. The models fit the CFD data with values ranging from 0.878 to 0.978, and predict that the optimum locations in terms of heat transfer are when the elements are positioned as close to the crown floor as possible ( and ?min. limits), where they come in direct contact with the air flow from the cabin ventilation system, and when they are positioned close to the centreline ( and ?CL). The methodology employed allows aircraft thermal designers to optimise equipment placement in confined areas of an aircraft during the design phase. The determined models should be incorporated into global aircraft numerical models to improve accuracy and reduce model size and computational time. © 2012 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a low-damage method for direct and rapid fabrication of arrays of epitaxial BiFeO3(BFO) nanoislands. An array of aluminium dots is evaporated through a stencil mask on top of an epitaxial BiFeO3 thin film. Low energy focused ion beam milling of an area several microns wide containing the array-covered film leads to removal of the bismuth ferrite in between the aluminium-masked dots. By chemical etching of the remaining aluminium, nanoscale epitaxial bismuth ferrite islands with diameter ∼250 nm were obtained. Piezoresponse force microscopy showed that as-fabricated structures exhibited good piezoelectric and ferroelectric properties, with polarization state retention of several days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulation of disorders of respiratory mechanics shown by spirometry provides insight into the pathophysiology of disease but some clinically important disorders have not been simulated and none have been formally evaluated for education. We have designed simple mechanical devices which, along with existing simulators, enable all the main dysfunctions which have diagnostic value in spirometry to be simulated and clearly explained with visual and haptic feedback. We modelled the airways as Starling resistors by a clearly visible mechanical action to simulate intra- and extra-thoracic obstruction. A narrow tube was used to simulate fixed large airway obstruction and inelastic bands to simulate restriction. We hypothesized that using simulators whose action explains disease promotes learning especially in higher domain educational objectives. The main features of obstruction and restriction were correctly simulated. Simulation of variable extra-thoracic obstruction caused blunting and plateauing of inspiratory flow, and simulation of intra-thoracic obstruction caused limitation of expiratory flow with marked dynamic compression. Multiple choice tests were created with questions allocated to lower (remember and understand) or higher cognitive domains (apply, analyse and evaluate). In a cross-over design, overall mean scores increased after 1½ h simulation spirometry (43-68 %, effect size 1.06, P < 0.0001). In higher cognitive domains the mean score was lower before and increased further than lower domains (Δ 30 vs 20 %, higher vs lower effect size 0.22, P < 0.05). In conclusion, the devices successfully simulate various patterns of obstruction and restriction. Using these devices medical students achieved marked enhancement of learning especially in higher cognitive domains.