24 resultados para Docker,ARM,Raspberry PI,single board computer,QEMU,Sabayon Linux,Gentoo Linux
Resumo:
Due to the intermittent nature of renewable generation it is desirable to consider the potential of controlling the demand-side load to smooth overall system demand. The architecture and control methodologies of such a system on a large scale would require careful consideration. Some of these considerations are discussed in this paper; such as communications infrastructure, systems architecture, control methodologies and security. A domestic fridge is used in this paper as an example of a controllable appliance. A layered approach to smart-grid is introduced and it can be observed how each smart-grid component from physical cables, to the end-devices (or smart-applications) can be mapped to these set layers. It is clear how security plays an integral part in each component of the smart-grid so this is also an integral part of each layer. The controllable fridge is described in detail and as one potential smart-grid application which maps to the layered approach. A demonstration system is presented which involves a Raspberry Pi (a low-power, low-cost device representing the appliance controller).
Resumo:
BACKGROUND: In the previously reported ALSYMPCA trial in patients with castration-resistant prostate cancer and symptomatic bone metastases, overall survival was significantly longer in patients treated with radium-223 dichloride (radium-223) than in patients treated with placebo. In this study, we investigated safety and overall survival in radium-223 treated patients in an early access programme done after the ALSYMPCA study and before regulatory approval of radium-223.
METHODS: We did an international, prospective, interventional, open-label, single-arm, phase 3b study. Enrolled patients were aged 18 years or older with histologically or cytologically confirmed progressive bone-predominant metastatic castration-resistant prostate cancer with two or more skeletal metastases on imaging (with no restriction as to whether they were symptomatic or asymptomatic; without visceral disease but lymph node metastases were allowed). Patients received intravenous injections of radium-223, 50 kBq/kg (current recommendation 55 kBq/kg after implementation of National Institute of Standards and Technology update on April 18, 2016) every 4 weeks for up to six injections. Other concomitant anticancer therapies were allowed. Primary endpoints were safety and overall survival. The safety and efficacy analyses were done on all patients who received at least one dose of the study drug. The study has been completed, and we report the final analysis here. This study is registered with ClinicalTrials.gov, number NCT01618370, and the European Union Clinical Trials Register, EudraCT number 2012-000075-16.
FINDINGS: Between July 22, 2012, and Dec 19, 2013, 839 patients were enrolled from 113 sites in 14 countries. 696 patients received one or more doses of radium-223; 403 (58%) of these patients had all six planned injections. Any-grade treatment-emergent adverse events occurred in 523 (75%) of 696 patients; any-grade treatment-emergent adverse events deemed to be related to treatment were reported in 281 (40%) patients. The most common grade 3 or worse treatment-related treatment-emergent adverse events were anaemia in 32 (5%) patients, thrombocytopenia in 15 (2%) patients, neutropenia in ten (1%) patients, and leucopenia in nine (1%) patients. Any grade of serious adverse events were reported in 243 (35%) patients. Median follow-up was 7·5 months (IQR 5-11) and 210 deaths were reported; median overall survival was 16 months (95% CI 13-not available [NA]). In an exploratory analysis of overall survival with predefined factors, median overall survival was longer for: patients with baseline alkaline phosphatase concentration less than the upper limit of normal (ULN; median NA, 95% CI 16 months-NA) than for patients with an alkaline phosphatase concentration equal to or greater than the ULN (median 12 months, 11-15); patients with baseline haemoglobin levels 10 g/dL or greater (median 17 months, 14-NA) than for patients with haemoglobin levels less than 10 g/dL (median 10 months, 8-14); patients with a baseline Eastern Cooperative Oncology Group performance status (ECOG PS) of 0 (median NA, 17 months-NA) than for patients with an ECOG PS of 1 (median 13 months, 11-NA) or an ECOG PS of 2 or more (median 7 months, 5-11); and for patients with no reported baseline pain (median NA, 16 months-NA) than for those with mild pain (median 14 months, 13-NA) or moderate-severe pain (median 11 months, 9-13). Median overall survival was also longer in patients who received radium-223 plus abiraterone, enzalutamide, or both (median NA, 95% CI 16 months-NA) than in those who did not receive these agents (median 13 months, 12-16), and in patients who received radium-223 plus denosumab (median NA, 15 months-NA) than in patients who received radium-223 without denosumab (median 13 months, 12-NA).
INTERPRETATION: Our findings show that radium-223 can be safely combined with abiraterone or enzalutamide, which are now both part of the standard of care for patients with metastatic castration-resistant prostate cancer. Furthermore, our findings extend to patients who were asymptomatic at baseline, unlike those enrolled in the pivotal ALSYMPCA study. The findings of prolonged survival in patients treated with concomitant abiraterone, enzalutamide, or denosumab require confirmation in prospective randomised trials.
FUNDING: Pharmaceutical Division of Bayer.
Resumo:
It is shown that a side-fed bifilar helix antenna with a single feed, can generate a slant 451 linearly polarized onmidirectional toroidal pattern. The antenna has a low profile and does not require a ground plane. The bifilar helix antenna provides slant 45 degrees polarization over a solid angle of almost 4 pi steradians as compared to a crossed dipole which generates a tilted 45 degrees linearly, polarized pattern only over a solid angle of 1.14 pi steradians. The computed results are validated by experimental data.
Resumo:
This paper investigates the learning of a wide class of single-hidden-layer feedforward neural networks (SLFNs) with two sets of adjustable parameters, i.e., the nonlinear parameters in the hidden nodes and the linear output weights. The main objective is to both speed up the convergence of second-order learning algorithms such as Levenberg-Marquardt (LM), as well as to improve the network performance. This is achieved here by reducing the dimension of the solution space and by introducing a new Jacobian matrix. Unlike conventional supervised learning methods which optimize these two sets of parameters simultaneously, the linear output weights are first converted into dependent parameters, thereby removing the need for their explicit computation. Consequently, the neural network (NN) learning is performed over a solution space of reduced dimension. A new Jacobian matrix is then proposed for use with the popular second-order learning methods in order to achieve a more accurate approximation of the cost function. The efficacy of the proposed method is shown through an analysis of the computational complexity and by presenting simulation results from four different examples.
Resumo:
In this paper, a novel video-based multimodal biometric verification scheme using the subspace-based low-level feature fusion of face and speech is developed for specific speaker recognition for perceptual human--computer interaction (HCI). In the proposed scheme, human face is tracked and face pose is estimated to weight the detected facelike regions in successive frames, where ill-posed faces and false-positive detections are assigned with lower credit to enhance the accuracy. In the audio modality, mel-frequency cepstral coefficients are extracted for voice-based biometric verification. In the fusion step, features from both modalities are projected into nonlinear Laplacian Eigenmap subspace for multimodal speaker recognition and combined at low level. The proposed approach is tested on the video database of ten human subjects, and the results show that the proposed scheme can attain better accuracy in comparison with the conventional multimodal fusion using latent semantic analysis as well as the single-modality verifications. The experiment on MATLAB shows the potential of the proposed scheme to attain the real-time performance for perceptual HCI applications.
Resumo:
REMA is an interactive web-based program which predicts endonuclease cut sites in DNA sequences. It analyses Multiple sequences simultaneously and predicts the number and size of fragments as well as provides restriction maps. The users can select single or paired combinations of all commercially available enzymes. Additionally, REMA permits prediction of multiple sequence terminal fragment sizes and suggests suitable restriction enzymes for maximally discriminatory results. REMA is an easy to use, web based program which will have a wide application in molecular biology research. Availability: REMA is written in Perl and is freely available for non-commercial use. Detailed information on installation can be obtained from Jan Szubert (jan.szubert@gmail.com) and the web based application is accessible on the internet at the URL http://www.macaulay.ac.uk/rema. Contact: b.singh@macaulay.ac.uk. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Silicon carbide (SiC) is a material of great technological interest for engineering applications concerning hostile environments where silicon-based components cannot work (beyond 623 K). Single point diamond turning (SPDT) has remained a superior and viable method to harness process efficiency and freeform shapes on this harder material. However, it is extremely difficult to machine this ceramic consistently in the ductile regime due to sudden and rapid tool wear. It thus becomes non trivial to develop an accurate understanding of tool wear mechanism during SPDT of SiC in order to identify measures to suppress wear to minimize operational cost.
In this paper, molecular dynamics (MD) simulation has been deployed with a realistic analytical bond order potential (ABOP) formalism based potential energy function to understand tool wear mechanism during single point diamond turning of SiC. The most significant result was obtained using the radial distribution function which suggests graphitization of diamond tool during the machining process. This phenomenon occurs due to the abrasive processes between these two ultra hard materials. The abrasive action results in locally high temperature which compounds with the massive cutting forces leading to sp3–sp2 order–disorder transition of diamond tool. This represents the root cause of tool wear during SPDT operation of cubic SiC. Further testing led to the development of a novel method for quantitative assessment of the progression of diamond tool wear from MD simulations.
Resumo:
The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm.
Resumo:
The SMART (SensoriMotor Active Rehabilitation Training) Arm is a nonrobotic device designed to allow stroke survivors with severe paresis to practice reaching. It can be used with or without outcome-triggered electrical stimulation (OT-stim) to augment movement. The aim of this study was to evaluate the efficacy of SMART Arm training when used with or without OT-stim, in addition to usual care, as compared with usual care alone during inpatient rehabilitation.