14 resultados para Diode array UV spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present high quality spectroscopic data for two massive stars in the OB 10 association of M31, OB 10-64 (B0 la) and OB 10-WRI (WC6). Medium resolution spectra of both stars were obtained using the ISIS spectrograph on the William Herschel Telescope. This is supplemented with Hubble Space Telescope STIS UV spectroscopy and Keck I HIRES data for OB 10-64. A non- local thermodynamic equilibrium (LTE) model atmosphere and abundance analysis for OB 10-64 is presented, indicating that this star has similar photospheric CNO, Mg and Si abundances to solar neighbourhood massive stars. A wind analysis of this early B-type supergiant reveals a mass-loss rate of (M)over dot = 1.6 x 10(-6) M-circle dot yr(-1), and v(infinity) = 1650 km s(-1). The corresponding wind momentum is in good agreement with the wind momentum-luminosity relationship found for Galactic early-B supergiants. Observations of OB 10-WRI are analysed using a non-LTE, line-blanketed code, to reveal approximate stellar parameters of log L/L-circle dot similar to 5.7, T-* - 75 kK, v(infinity) similar to 3000 km s(-1), (M)over dot/(M-circle dot yr(-1)) similar to 10(-4.3) adopting a clumped wind with a filling factor of 10 per cent. Quantitative comparisons are made with the Galactic WC6 star HD 92809 (WR23) revealing that OB 10-WR1 is 0.4 dex more luminous, though it has a much lower C/He ratio (similar to0.1 versus 0.3 for HD 92809). Our study represents the first detailed, chemical model atmosphere analysis for either a B-type supergiant or a Wolf- Rayet (WR) star in Andromeda, and shows the potential of how such studies can provide new information on the chemical evolution of galaxies and the evolution of massive stars in the local Universe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three plasma diagnostic methods, tunable infrared diode laser absorption spectroscopy, optical emission spectroscopy and microwave interferometry have been used to monitor concentrations of transient and stable molecules, CH3, CH4, C2H2, C2H6, and of electrons in capacitively coupled CH4-H-2-Ar radiofrequency (RF) plasmas (f(RF) = 13.56 MHz, p = 100 Pa, phi (total)= 66 sccm) for various discharge power values (P = 10-100 W) and gas mixtures. The degree of dissociation of the methane precursor varied between 3% and 60%. The methyl radical concentration was found to be in the order of 10(12) molecules cm(-3) and the electron concentration in the order of loll cm(-3). The methyl radical concentration and the concentrations of the stable C-2 hydrocarbons, C2H2 and C2H6, produced in the plasma, increased with discharge power. The fragmentation rates of the methane precursor and conversion rates to the measured C-2 hydrocarbons were estimated in dependence on discharge power. Radial distributions of the electron and methyl radical concentrations, and of the gas temperature were measured for the first time simultaneously in the plasma region between the discharge electrodes. The measurements allow us to draw qualitative conclusions on the main chemical processes and the plasma chemical reaction paths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim was to investigate the association between periodontal health and the serum levels of various antioxidants including carotenoids, retinol and vitamin E in a homogenous group of Western European men.
Materials and Methods: A representative sample of 1258 men aged 60-70 years, drawn from the population of Northern Ireland, was examined between 2001 and 2003. Each participant had six or more teeth, completed a questionnaire and underwent a clinical periodontal examination. Serum lipid-soluble antioxidant levels were measured by high-performance liquid chromatography with diode array detection. Multivariable analysis was carried out using logistic regression with adjustment for possible confounders. Models were constructed using two measures of periodontal status (low- and high-threshold periodontitis) as dependent variables and the fifths of each antioxidant as a predictor variable.
Results: The levels of a- and ß-carotene, ß-cryptoxanthin and zeaxanthin were highly significantly lower in the men with low-threshold periodontitis (p<0.001). These carotenoids were also significantly lower in high-threshold periodontitis. There were no significant differences in the levels of lutein, lycopene, a- and ?-tocopherol or retinol in relation to periodontitis. In fully adjusted models, there was an inverse relationship between a number of carotenoids (a- and ß-carotene and ß-cryptoxanthin) and low-threshold periodontitis. ß-Carotene and ß-cryptoxanthin were the only antioxidants that were associated with an increased risk of high-threshold severe periodontitis. The adjusted odds ratio for high-threshold periodontitis in the lowest fifth relative to the highest fifth of ß-cryptoxanthin was 4.02 (p=0.003).
Conclusion: It is concluded that low serum levels of a number of carotenoids, in particular beta-cryptoxanthin and beta-carotene, were associated with an increased prevalence of periodontitis in this homogenous group of 60-70-year-old Western European men.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated and characterised transdermal permeation of bioactive agents from a topically applied Arnica montana tincture. Permeation experiments conducted over 48 h used polydimethylsiloxane (silastic) and human epidermal membranes mounted in Franz-type diffusion cells with a methanol-water (50:50 v/v) receptor fluid. A commercially available tincture of A. montana L. derived from dried Spanish flower heads was a donor solution. Further donor solutions prepared from this stock tincture concentrated the tincture constituents 1, 2 and 10 fold and its sesquiterpene lactones 10 fold. Permeants were assayed using a high-performance liquid chromatography method. Five components permeated through silastic membranes providing peaks with relative retention factors to an internal standard (santonin) of 0.28, 1.18, 1.45, 1.98 and 2.76, respectively. No permeant was detected within 12 h of applying the Arnica tincture onto human epidermal membranes. However, after 12 h, the first two of these components were detected. These were shown by Zimmermann reagent reaction to be sesquiterpene lactones and liquid chromatography/diode array detection/mass spectrometry indicated that these two permeants were 11,13-dihydrohelenalin (DH) analogues (methacrylate and tiglate esters). The same two components were also detected within 3 h of topical application of the 10-fold concentrated tincture and the concentrated sesquiterpene lactone extract.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbamyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 microm ODS (C18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min-1 and the column temperature was maintained at 30 degrees C. Galactosamine hydrochloride (Gal-HCl) was used as an internal standard. Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32+/-1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15+/-0.1 cm2. The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1% v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 microg ml-1. The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) <12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <or=-5.60 and <or=-8.00, respectively. Using this assay, it was found that GL-HCl permeates through human skin with a flux 1.497+/-0.42 microg cm-2 h-1, a permeability coefficient of 5.66+/-1.6x10(-6) cm h-1 and with a lag time of 10.9+/-4.6 h.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A detailed knowledge of the physical phenomena underlying the generation and the transport of fast electrons generated in high-intensity laser-matter interactions is of fundamental importance for the fast ignition scheme for inertial confinement fusion.

Here we report on an experiment carried out with the VULCAN Petawatt beam and aimed at investigating the role of collisional return currents in the dynamics of the fast electron beam. To that scope, in the experiment counter-propagating electron beams were generated by double-sided irradiation of layered target foils containing a Ti layer. The experimental results were obtained for different time delays between the two laser beams as well as for single-sided irradiation of the target foils. The main diagnostics consisted of two bent mica crystal spectrometers placed at either side of the target foil. High-resolution X-ray spectra of the Ti emission lines in the range from the Ly alpha to the K alpha line were recorded. In addition, 2D X-ray images with spectral resolution were obtained by means of a novel diagnostic technique, the energy-encoded pin-hole camera, based on the use of a pin-hole array equipped with a CCD detector working in single-photon regime. The spectroscopic measurements suggest a higher target temperature for well-aligned laser beams and a precise timing between the two beams. The experimental results are presented and compared to simulation results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A UVB specific dosimeter is described comprising: a redox dye (2,6-dichloroindophenol, DCIP), a semiconductor ( tin(IV) oxide, SnO2) and a sacrificial electron donor ( glycerol) dispersed in a polymer ( hydroxy ethyl cellulose, HEC) film. The dosimeter is blue in the absence of UVB light but rapidly loses colour on exposure to UVB light. The spectral characteristics of a typical UVB dosimeter film and the mechanism by which the colour change occurs are detailed. DCIP UVB dosimeter films exhibit a response that is related to the irradiance level and duration of UVB exposure, the level of SnO2 present and to a lesser extent the level of glycerol present. The response of the dosimeter appears to be independent of dye concentration and film thickness. Furthermore, DCIP UVB dosimeter films respond to solar simulated light, exhibiting a colour loss that can be simply related to the Minimal Erythemal Dose (MED) exposure for skin type II. As a consequence, such indicators have potential for measuring solar radiation exposure and providing an early warning of erythema for most Caucasian skin (i.e. skin type II).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concentration of organic acids in anaerobic digesters is one of the most critical parameters for monitoring and advanced control of anaerobic digestion processes. Thus, a reliable online-measurement system is absolutely necessary. A novel approach to obtaining these measurements indirectly and online using UV/vis spectroscopic probes, in conjunction with powerful pattern recognition methods, is presented in this paper. An UV/vis spectroscopic probe from S::CAN is used in combination with a custom-built dilution system to monitor the absorption of fully fermented sludge at a spectrum from 200 to 750 nm. Advanced pattern recognition methods are then used to map the non-linear relationship between measured absorption spectra to laboratory measurements of organic acid concentrations. Linear discriminant analysis, generalized discriminant analysis (GerDA), support vector machines (SVM), relevance vector machines, random forest and neural networks are investigated for this purpose and their performance compared. To validate the approach, online measurements have been taken at a full-scale 1.3-MW industrial biogas plant. Results show that whereas some of the methods considered do not yield satisfactory results, accurate prediction of organic acid concentration ranges can be obtained with both GerDA and SVM-based classifiers, with classification rates in excess of 87% achieved on test data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication and operation of an ammonia chemoresistor is described. The sensor responds to changes in the resistance (impedance) of a thin layer of conductive polymer is due to changes in ammonia concentration. The polyaniline film was deposited by electroless plating (dipping) method on interdigitated array made by photolithographic technique. The PANI film was characterized by UV/VIS and IR Spectroscopy and respectively, Atomic Force Microscopy. Impedance Spectroscopy was used for sensor characterization

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The adsorption of water and deuterium oxide on TiO2 surfaces was investigated in the dark as well as under UV(A) irradiation using in situ ATR-FTIR spectroscopy under oxygen and oxygen free conditions. Adsorption of H2O-D2O mixtures revealed an isotopic exchange reaction occurring onto the surface of TiO2 in the dark. Under UV(A) irradiation, the amount of both OH and OD groups was found to be increased by the presence of molecular oxygen. Furthermore, the photocatalytic formation of hydroperoxide under oxygenated condition has been recorded utilizing Attenuated Total Reflection Fourier Transformed Infrared (ATR-FTIR) spectroscopy which appeared as new band at 3483 cm-1. Different possible mechanisms are discussed in terms of the source of hydroxyl groups formed and/or hydration water on the TiO2 surface for the photocatalytic reaction and photoinduced hydrophilicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the Pan-STARRS1 discovery of the long-lived and blue transient PS1-11af, which was also detected by Galaxy Evolution Explorer with coordinated observations in the near-ultraviolet (NUV) band. PS1-11af is associated with the nucleus of an early type galaxy at redshift z = 0.4046 that exhibits no evidence for star formation or active galactic nucleus activity. Four epochs of spectroscopy reveal a pair of transient broad absorption features in the UV on otherwise featureless spectra. Despite the superficial similarity of these features to P-Cygni absorptions of supernovae (SNe), we conclude that PS1-11af is not consistent with the properties of known types of SNe. Blackbody fits to the spectral energy distribution are inconsistent with the cooling, expanding ejecta of a SN, and the velocities of the absorption features are too high to represent material in homologous expansion near a SN photosphere. However, the constant blue colors and slow evolution of the luminosity are similar to previous optically selected tidal disruption events (TDEs). The shape of the optical light curve is consistent with models for TDEs, but the minimum accreted mass necessary to power the observed luminosity is only 0.002 M, which points to a partial disruption model. A full disruption model predicts higher bolometric luminosities, which would require most of the radiation to be emitted in a separate component at high energies where we lack observations. In addition, the observed temperature is lower than that predicted by pure accretion disk models for TDEs and requires reprocessing to a constant, lower temperature. Three deep non-detections in the radio with the Very Large Array over the first two years after the event set strict limits on the production of any relativistic outflow comparable to Swift J1644+57, even if off-axis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulsatile, or “on-demand”, delivery systems have the capability to deliver a therapeutic molecule at the right time/site of action and in the right amount (1). Pulsatile delivery systems present multiple benefits over conventional dosage forms and provide higher patient compliance. The combination of stimuli-responsive materials with the drug delivery capabilities of hydrogel-forming MN arrays (2) opens an interesting area of research. In the present work we describe, a stimuli-responsive hydrogel-forming microneedle (MN) array that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of UV radiation (Figure 1A). MN arrays were prepared using a micromolding technique using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) (Figure 1B). The arrays were loaded with up to 5% (w/w) ibuprofen included in a light-responsible conjugate (3,5-dimethoxybenzoin conjugate) (2). The presence of the conjugate inside the MN arrays was confirmed by Raman spectroscopy measurements. MN arrays were tested in vitro showing that they were able to deliver up to three doses of 50 mg of ibuprofen after application of an optical trigger (wavelength of 365 nm) over a long period of time (up to 160 hours) (Figure 1C and 1D). The work presented here is a probe of concept and a modified version of the system should be used as UV radiation is shown to be the major etiologic agent in the development of skin cancers. Consequently, for future applications of this technology an alternative design should be developed. Based on the previous research dealing with hydrogel forming MN arrays a suitable strategy will be to use hydrogel-forming MN arrays containing a backing layer made with the material described in this work as the drug reservoir (2). Finally, a porous layer of a material that blocks UV radiation should be included between the MN array and the drug reservoir. Therefore radiation can be applied to the system without reaching the skin surface. Therefore after modification, the system described here interesting properties as “on-demand” release system for prolonged periods of time. This technology has potential for use in “on-demand” delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.