13 resultados para Composite Measurement Scales
Resumo:
A full-scale 34 m composite wind turbine blade was tested to failure under flap-wise loading. Local displacement measurement equipment was developed and displacements were recorded throughout the loading history.
Ovalization of the load carrying box girder was measured in the full-scale test and simulated in non-linear FE-calculations. The nonlinear Brazier effect is characterized by a crushing pressure which causes the ovalization. To capture this effect, non-linear FE-analyses at different scales were employed. A global non-linear FE-model of the entire blade was prepared and the boundaries to a more detailed sub-model were extracted. The FE-model was calibrated based on full-scale test measurements.
Local displacement measurements helped identify the location of failure initiation which lead to catastrophic failure. Comparisons between measurements and FE-simulations showed that delamination of the outer skin was the initial failure mechanism followed by delamnination buckling which then led to collapse.
Resumo:
The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This study presents a measurement-based method for the early detection of power system oscillations, with consideration of mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet-based support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in frequency bands, whereas the SVDD method is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude, or that are resonant, can be alarmed to the system operator, to reduce the risk of system instability. The proposed method is exemplified using measured data from a chosen wind farm site.
Resumo:
The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly-fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This paper presents a measurement based method for the early detection of power system oscillations, with attention to mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet transform and support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in different frequency bands, while SVDD is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude or that are resonant can be alarmed to the system operator, to reduce the risk of system instability. Method evaluation is exemplified used real data from a chosen wind farm.
Resumo:
Background: Previous research demonstrates various associations between depression, cardiovascular disease (CVD) incidence and mortality, possibly as a result of the different methodologies used to measure depression and analyse relationships. This analysis investigated the association between depression, CVD incidence (CVDI) and mortality from CVD (MCVD), smoking related conditions (MSRC), and all causes (MALL), in a sample data set, where depression was measured using items from a validated questionnaire and using items derived from the factor analysis of a larger questionnaire, and analyses were conducted based on continuous data and grouped data.
Methods: Data from the PRIME Study (N=9798 men) on depression and 10-year CVD incidence and mortality were analysed using Cox proportional hazards models.
Results: Using continuous data, both measures of depression resulted in the emergence of positive associations between depression and mortality (MCVD, MSRC, MALL). Using grouped data, however, associations between a validated measure of depression and MCVD, and between a measure of depression derived from factor analysis and all measures of mortality were lost.
Limitations: Low levels of depression, low numbers of individuals with high depression and low numbers of outcome events may limit these analyses, but levels are usual for the population studied.
Conclusions: These data demonstrate a possible association between depression and mortality but detecting this association is dependent on the measurement used and method of analysis. Different findings based on methodology present clear problems for the elucidation and determination of relationships. The differences here argue for the use of validated scales where possible and suggest against over-reduction via factor analysis and grouping.
Resumo:
This paper presents an experimental and numerical study focused on the tensile fibre fracture toughness characterisation of hybrid plain weave composite laminates using non-standardized Overheight Compact Tension (OCT) specimens. The position as well as the strain field ahead of the crack tip in the specimens was determined using a digital speckle photogrammetry system. The limitation on the applicability of standard data reduction schemes for the determination of the intralaminar fibre fracture toughness of composites is presented and discussed. A methodology based on the numerical evaluation of the strain energy release rate using the J-integral method is proposed to derive new geometric correction functions for the determination of stress intensity factor for alternative composite specimen geometries. A comparison between different methods currently available to compute the intralaminar fracture toughness in composites is also presented and discussed. Good agreement between numerical and experimental results using the proposed methodology was obtained.
Resumo:
This paper presents a current and turbulence measurement campaign conducted at a test site in an energetic tidal channel known as Strangford Narrows, Northern Ireland. The data was collected as part of the MaRINET project funded by the EU under their FP7 framework. It was a collaborative effort between Queen’s University Belfast, SCHOTTEL and Fraunhofer IWES. The site is highly turbulent with a strong shear flow. Longer term measurements of the flow regime were made using a bottom mounted Acoustic Doppler Profiler (ADP). During a specific turbulence measurement campaign, two collocated in- struments were used to measure incoming flow characteristics: an ADP (Aquadopp, Nortek) and a turbulence profiler (MicroRider, Rockland Scientific International). The instruments recorded the same incoming flow, so that direct comparisons between the data can be made. In this study the methodology adopted to deploy the instruments is presented. The resulting turbulence measurements using the different types of instrumentation are compared and the usefulness of each instrument for the relevant range of applications is discussed. The paper shows the ranges of the frequency spectra obtained using the different instruments, with the combined measurements providing insight into the structure of the turbulence across a wide range of scales.
Resumo:
In this paper we propose a new composite fadingmodel which assumes that the mean signal power of an η−µ signalenvelope follows an inverse gamma distribution. The inversegamma distribution has a simple relationship with the gammadistribution and can be used to model shadowed fading due to itssemi heavy-tailed characteristics. To demonstrate the utility of thenew η−µ / inverse gamma composite fading model, we investigatethe characteristics of the shadowed fading behavior observed inbody centric communications channels which are known to besusceptible to shadowing effects, particularly generated by thehuman body. It is shown that the η−µ / inverse gamma compositefading model provided an excellent fit to the measurement data.Moreover, using Kullback-Leibler divergence, the η −µ / inversegamma composite fading model was found to provide a better fitto the measured data than the κ − µ / inverse gamma compositefading model, for the communication scenarios considered here.
Resumo:
Abstract: Psychometric properties of two self-report clinical competence scales for nursing students.
Background: It is important to assess the clinical competence of nursing students to gauge their professional development and educational needs. This can be measured by self-assessment tools. Anema and McCoy (2010) contended that the currently available measures need further psychometric testing.
Aim: To test the psychometric properties of Nursing Competencies Questionnaire (NCQ) and Self-Efficacy in Clinical Performance (SECP) clinical competence scales.
Method: A non-randomly selected sample of n=248 2nd year nursing students completed NCQ, SECP and demographic questionnaires (June and September 2013). Mokken Scaling Analysis (MSA) was used to test the structural validity and scale properties, convergent and discriminant validity and reliability were subsequently tested.
Results: The NCQ provided evidence of a unidimensional scale which had strong scale scalability coefficients Hs =0.581; but limited evidence of item rankability HT =0.367. MSA undertaken with the SECP scale identified two potential unidimensional scales the SECP28 and SECP7, each with adequate evidence of good/reasonable scalablity psychometric properties as a summed scale but no/very limited evidence of scale rankability (SECP28: Hs = 0.55, HT=0.211; SECP7: Hs = 0.61, HT=0.049). Analysis of between cohort differences and NCQ/ SECP scale scores produced evidence of convergent and discriminant validity and good internal reliability: NCQ α = 0.93, SECP28 α = 0.96, and SECP7 α=0.89.
Discussion: The NCQ was verified to have evidence of reliability and validity; however, as the SECP findings are new, and the sample small, with reference to Straat and colleagues (2014), the SECP results should be interpreted with caution and verified on a second sample.
Conclusions: Measurement of perceived self-competence could inform the development of nursing competence and could start early in a nursing programme. Further testing of the NCQ and SECP scales with larger samples and from different years is indicated.
References:
Anema, M., G and McCoy, JK. (2010) Competency-Based Nursing Education: Guide to Achieving Outstanding Learner Outcomes. New York: Springer.
Straat, JH., van der Ark, LA and Sijtsma, K. (2014) Minimum Sample Size Requirements for Mokken Scale Analysis Educational and Psychological Measurement 74 (5), 809-822.
Resumo:
Natural mineral-water interface reactions drive ecosystem/global fluoride (F−) cycling. These small-scale processes prove challenging to monitoring due to mobilization being highly localized and variable; influenced by changing climate, hydrology, dissolution chemistries and pedogenosis. These release events could be captured in situ by the passive sampling technique, diffusive gradients in thin-films (DGT), providing a cost-effective and time-integrated measurement of F− mobilization. However, attempts to develop the method for F− have been unsuccessful due to the very restrictive operational ranges that most F−-absorbents function within. A new hybrid-DGT technique for F− quantification containing a three-phase fine particle composite (Fesingle bondAlsingle bondCe, FAC) adsorbent was developed and evaluated. Sampler response was validated in laboratory and field deployments, passing solution chemistry QC within ionic strength and pH ranges of 0–200 mmol L−1 and 4.3–9.1, respectively, and exhibiting high sorption capacities (98 ± 8 μg cm−2). FAC-DGT measurements adequately predicted up to weeklong averaged in situ F− fluvial fluxes in a freshwater river and F− concentrations in a wastewater treatment flume determined by high frequency active sampling. While, millimetre-scale diffusive fluxes across the sediment-water interface were modeled for three contrasting lake bed sediments from a F−-enriched lake using the new FAC-DGT platform.
Resumo:
The predictive capability of high fidelity finite element modelling, to accurately capture damage and crush behaviour of composite structures, relies on the acquisition of accurate material properties, some of which have necessitated the development of novel approaches. This paper details the measurement of interlaminar and intralaminar fracture toughness, the non-linear shear behaviour of carbon fibre (AS4)/thermoplastic Polyetherketoneketone (PEKK) composite laminates and the utilisation of these properties for the accurate computational modelling of crush. Double-cantilever-beam (DCB), four-point end-notched flexure (4ENF) and Mixed-mode bending (MMB) test configurations were used to determine the initiation and propagation fracture toughness in mode I, mode II and mixed-mode loading, respectively. Compact Tension (CT) and Compact Compression (CC) test samples were employed to determine the intralaminar longitudinal tensile and compressive fracture toughness. V-notched rail shear tests were used to measure the highly non-linear shear behaviour, associated with thermoplastic composites, and fracture toughness. Corresponding numerical models of these tests were developed for verification and yielded good correlation with the experimental response. This also confirmed the accuracy of the measured values which were then employed as input material parameters for modelling the crush behaviour of a corrugated test specimen.
Resumo:
Background: It is important to assess the clinical competence of nursing students to gauge their educational needs. Competence can be measured by self-assessment tools; however, Anema and McCoy (2010) contend that currently available measures should be further psychometrically tested.
Aim: To test the psychometric properties of Nursing Competencies Questionnaire (NCQ) and Self-Efficacy in Clinical Performance (SECP) clinical competence scales.
Method: A non-randomly selected sample of n=248 2nd year nursing students completed NCQ, SECP and demographic questionnaires (June and September 2013). Mokken Scaling Analysis (MSA) was used to investigate structural validity and scale properties; convergent and discriminant validity and reliability were also tested for each scale.
Results: MSA analysis identified that the NCQ is a unidimensional scale with strong scale scalability coefficients Hs =0.581; but limited item rankability HT =0.367. The SECP scale MSA suggested that the scale could be potentially split into two unidimensional scales (SECP28 and SECP7), each with good/reasonable scalablity psychometric properties as summed scales but negligible/very limited scale rankability (SECP28: Hs = 0.55, HT=0.211; SECP7: Hs = 0.61, HT=0.049). Analysis of between cohort differences and NCQ/SECP scores produced evidence of discriminant and convergent validity; good internal reliability was also found: NCQ α = 0.93, SECP28 α = 0.96 and SECP7 α=0.89.
Discussion: In line with previous research further evidence of the NCQ’s reliability and validity was demonstrated. However, as the SECP findings are new and the sample small with reference to Straat and colleagues (2014), the SECP results should be interpreted with caution and verified on a second sample.
Conclusions: Measurement of perceived self-competence could start early in a nursing programme to support students’ development of clinical competence. Further testing of the SECP scale with larger nursing student samples from different programme years is indicated.
References:
Anema, M., G and McCoy, JK. (2010) Competency-Based Nursing Education: Guide to Achieving Outstanding Learner Outcomes. New York: Springer.
Straat, JH., van der Ark, LA and Sijtsma, K. (2014) Minimum Sample Size Requirements for Mokken Scale Analysis Educational and Psychological Measurement 74 (5), 809-822.