109 resultados para Charge relative
Resumo:
Absolute cross sections have been measured for single and double charge exchange and x-ray line emission for highly charged ions of C, N, 0, and Ne colliding with He, H-2 CO2, and H2O at collisions energies of 7q keV. Present results of charge exchange in He and H-2 compare favorably with previous results. For CO2 and H2O, where prior work is scarce, the classical overbarrier model is found to overestimate results by up to a factor of 3. An analysis of the relative intensities of the observed Lyman x-ray transitions indicates that capture into l states is not statistical, as collision velocities are insufficient to populate the highest angular-momentum states. The importance of autoionization following multiple capture is highlighted, and enhanced radiative stabilization following double capture is observed and compared to other studies. Present results are also discussed in terms of mechanisms likely to generate x-ray emission in comets.
Effects of Charge Location on the Absorptions and Lifetimes of Protonated Tyrosine Peptides in Vacuo
Resumo:
Nearby charges affect the electronic energy levels of chromophores, with the extent of the effect being determined by the magnitude of the charge and degree of charge-chromophore separation. The molecular configuration dictates the charge chromophore distance. Hence, in this study, we aim to assess how the location of the charge influences the absorption of a set of model protonated and diprotonated peptide ions, and whether spectral differences are large enough to be identified. The studied ions were the dipeptide YK, the tripeptide KYK (Y = tyrosine; K = lysine) and their complexes with 18-crown-6-ether (CE). The CE targets the ammonium group by forming internal ionic hydrogen bonds and limits the folding of the peptide. In the tripeptide, the distance between the chromophore and the backbone ammonium is enlarged relative to that in the dipeptide. Experiments were performed in an electrostatic ion storage ring using a tunable laser system, and action spectra based on lifetime measurements were obtained in the range from 210 to 310 nm. The spectra are all quite similar though there seems to be some changes in the absorption band between 210 and 250 nm, while in the lower energy band all ions had a maximum absorption at similar to 275 nm. Lifetimes after photoexcitation were found to shorten upon protonation and lengthen upon CE complexation, in accordance with the increased number of degrees of freedom and an increase in activation energies for dissociation as the mobile proton model is no longer operative.
Resumo:
The importance of relative motion information when modelling a novel motor skill was examined. Participants were assigned to one of four groups. Groups 1 and 2 viewed demonstrations of a skilled cricket bowler presented in either video or point light format. Group 3 observed a single point of light pertaining to the wrist of the skilled bowler only. Participants in Group 4 did not receive a demonstration and acted as controls. During 60 acquisition trials, participants in the demonstration groups viewed a model five times before each 10-trial block. Retention was examined the following day. Intra-limb coordination was assessed for the right elbow relative to the wrist in comparison to the model. The demonstration groups showed greater concordance with the model than the control group. However, the wrist group performed less like the model than the point light and video groups, who did not differ from each other. These effects were maintained in retention. Relative motion information aided the acquisition of intra-limb coordination, while making this information more salient (through point lights) provided no additional benefit. The motion of the models bowling arm was replicated more closely than the non-bowling arm, suggesting that information from the end-effector is prioritized during observation for later reproduction.
Resumo:
Integrated "ICT chromophore-receptor" systems show ion-induced shifts in their electronic absorption spectra. The wavelength of observation can be used to reversibly configure the system to any of the four logic operations permissible with a single input (YES, NOT, PASS 1, PASS 0), under conditions of ion input and transmittance output. We demonstrate these with dyes integrated into Tsien's calcium receptor, 1-2. Applying multiple ion inputs to 1-2 also allows us to perform two- or three-input OR or NOR operations. The weak fluorescence output of 1 also shows YES or NOT logic depending on how it is configured by excitation and emission wavelengths. Integrated "receptor(1)-ICT chromophore-receptor(2)" systems 3-5 selectively target two ions into the receptor terminals. The ion-induced transmittance output of 3-5 can also be configured via wavelength to illustrate several logic types including, most importantly, XOR. The opposite effects of the two ions on the energy of the chromophore excited state is responsible for this behaviour. INHIBIT and REVERSE IMPLICATION are two of the other logic types seen here. Integration of XOR logic with a preceding OR operation can be arranged by using three ion inputs. The fluorescence output of these systems can be configured via wavelength to display INHIBIT or NOR logic under two-input conditions. The superposition or multiplicity of logic gate configurations is an unusual consequence of the ability to simultaneously observe multiple wavelengths.
Resumo:
Relative Evidential Supports (RES) was developed and justified several years ago as a non-numeric apparatus that allows us to compare evidential supports for alternative conclusions when making a decision. An extension called Graded Relative Evidence (GRE) of the RES concept of pairwise balancing and trading-off of evidence is reported here which keeps its basic features of simplicity and perspicacity but enriches its modelling fidelity by permitting very modest and intuitive variations in degrees of outweighing (which the essentially binary RES does not). The formal justification is very simply based on linkages to RES and to the Dempster - Shafer theory of evidence. The use of the simple extension is illustrated and to a small degree further justified empirically by application to a topical scientific debate about what is called the Congo Crossover Conjecture here. This decision-making instance is chosen because of the wealth of evidence that has been accumulated on both sides of the debate and the range of evidence strengths manifested in it. The conjecture is that the advent of Aids was in the late 1950s in the Congo when a vaccine for polio was allegedly cultivated in the kidneys of chimpanzees which allowed the Aids infection to cross over to humans from primates. © 2005 Springer.
Resumo:
The charge state distributions of Fe, Na, and F are determined in a photoionized laboratory plasma using high resolution x-ray spectroscopy. Independent measurements of the density and radiation flux indicate unprecedented values for the ionization parameter ���¾=20 25 erg cm s-1 under near steady-state conditions. Line opacities are well fitted by a curve-of-growth analysis which includes the effects of velocity gradients in a one-dimensional expanding plasma. First comparisons of the measured charge state distributions with x-ray photoionization models show reasonable agreement.
Resumo:
The electron beam ions traps (EBITs) are widely used to study highly charged ions (HCIs). In an EBIT, a high energy electron beam collides with atoms and ions to generate HCIs in the trap region. It is important to study the physics in the trap. The atomic processes, such as electron impact ionisation (EI), radiative recombination (RR), dielectronic recombination (DR) and charge exchange (CX), occur in the trap and numerical simulation can give some parameters for design, predict the composition and describe charge state evolution in an EBIT [Phys. Rev. A 43 (199 1) 4861]. We are presently developing a new code, which additionally includes a description of the overlaps between the ion clouds of the various charge-states. It has been written so that it can simulate experiments where various machine parameters (e.g. beam energy and current) can vary throughout the simulation and will be able to use cross- sections either based on scaling laws or derived from atomic structure calculations. An object-oriented method is used in developing the new software, which is an efficient way to organize and write code. (C) 2003 Elsevier Science B.V. All rights reserved.