218 resultados para Capture Enzyme-immunoassay
Resumo:
Porcine urine enzyme immunoassays for sulfamethazine and sulfadiazine have previously been employed as screening tests to predict the concentrations of the drugs in the corresponding tissues (kidneys), If a urine was found positive (> 800 ng ml(-1)) the corresponding kidney was then analysed by an enzyme immunoassay and, if found positive, a confirmatory analysis by HPLC was performed. Urine was chosen as the screening matrix since sulfonamides are mainly eliminated through this body fluid, However, after obtaining a number of false positive predictions, an investigation was carried out to assess the possibility of using an alternative body fluid which would act as a superior indicator of the presence of sulfonamides in porcine kidney, An initial study indicated that serum, plasma and bile could all be used as screening matrices. From these, bile was chosen as the preferred sample matrix and an extensive study followed to compare the efficiencies of sulfonamide positive bile and urine at predicting sulphonamide positive kidneys, Bile was found to be 17 times more efficient than urine at predicting a sulfamethazine positive kidney and 11 times more efficient at predicting a sulfadiazine positive kidney, With this enhanced performance of the initial screening test, the need for the costly and time consuming kidney enzyme immunoassay, prior to HPLC analysis, was eliminated
Resumo:
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed-all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CC beta) of 0.25 mu g kg(-1) when a threshold of 0.21 mu g kg(-1) is applied to the selection of samples for confirmation (lowest observed 0.25 mu g kg(-1) fortified sample, n = 20), thus satisfying the EU nitrofurans' minimum required performance limit of 1 mu g kg(-1). N-FZ-incurred muscles (12) containing SEM at 0.5-5.0 mu g kg(-1) by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver. (C) 2007 Elsevier BN. All rights reserved.
Resumo:
Furazolidone, a nitrofuran antibiotic, is banned from use in food animal production within the European Union. Increasingly, compliance with this ban is monitored by use of analytical methods to detect a stable tissue-bound metabolite, 3-amino-2-oxazolidinone (AOZ). Widespread use of furazolidone in poultry and prawns imported into Europe highlighted the urgent need for development of nitrofuran immunoassay screening tests. The first enzyme-linked immunoabsorbant assay for detection of AOZ residues in prawns (shrimps) is now described. Prawn samples were derivatized with o-nitrobenzaldehyde, extracted into ethyl acetate, washed with hexane and applied to a competitive enzyme immunoassay based on a rabbit polyclonal antiserum. Assay limit of detection (LOD) (mean+3 s) calculated from the analysis of 20 known negative cold and warm water prawn samples was 0.1 mug kg(-1). Intra- and interassay relative standard deviations were determined as 18.8 and 38.2%, respectively, using a negative prawn fortified at 0.7 mug kg(-1). The detection capability (CCbeta), defined as the concentration of AOZ at which 20 different fortified samples yielded results above the LOD, was achieved at fortification between 0.4 and 0.7 mug kg(-1). Incurred prawn samples (n=8) confirmed by liquid chromatography coupled with tandem mass spectrometry detection to contain AOZ concentrations between 0.4 and 12.7 mug kg(-1) were all screened positive by this enzyme-linked immunoabsorbant assay. Further data are presented and discussed with regard to calculating assay LOD based on accepting a 5% false-positive rate with representative negative prawn samples. Such an acceptance improves the sensitivity of an ELISA and in this case permitted an LOD of 0.05 mug kg(-1) and a CCbeta of below 0.4 mug kg(-1).
Resumo:
Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for the detection and quantification of monensin residues in liver has been developed, Samples (3 g) were extracted with acetonitrile-water and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised against a monensin-transferrin conjugate, The limit of detection (mean + 3s) calculated from the analysis of 12 known negative samples was 2.91 ng g(-1). Intra- and inter-assay RSD were determined as 8.5 and 10.6%, respectively, using a liver sample fortified with 20 ng g(-1) monensin, A pharmacokinetic study in which 70 six week old broilers were fed monensin at a rate of 120 mg kg(-1) in their feed for 14 d resulted in mean monensin liver residues of 102 ng g(-1). However these had fallen below the limit of detection of the assay within the 3 d withdrawal period recommended by the manufacturer.
Resumo:
Ivermectin, a member of the avermectin group, is frequently used to control parasites in many food producing animal species. A method for the detection and quantification of ivermectin residues in bovine liver has been developed. Liver samples (4 g) were extracted with acetonitrile and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised in rabbits against an ivermectin-transferrin conjugate, The limit of detection of the assay (mean +/- 3s) calculated from the analysis of 24 known negative samples was 1.6 ng g(-1), Intra- and inter-assay RSDs were determined as 8.8 and 14.6%, respectively, using a negative bovine liver sample fortified with 100 ng g(-1) of ivermectin. Four Friesian steers were treated with a pour-on application of ivermectin at a dose rate of 0.5 mg kg(-1) body mass then withdrawn and killed at 7, 14, 21 and 28 d, Livers mere removed and ivermectin residue concentrations determined using the proposed immunoassay procedure, Seven days post-treatment the ivermectin liver concentration was determined as 52.7 ng g(-1), decreasing to 4.1 ng(-1) at 28 d, All immunoassay results were confirmed using high-performance liquid chromatography (HPLC), The immunoassay and HPLC results for invermectin ranged from 1 to 58 ng g(-1) and were in close correlation (r = 0.99).
Resumo:
A new competitive enzyme immunoassay technique has been developed for the determination of concentrations of the trypanocidal drug isometamidium chloride (Samorin) in bovine serum. The method has been shown to be highly repeatable and reproducible, and it has several advantages over previous immunoassay techniques for the drug. There are fewer incubation steps overall; microtitre plates may be of coated in batches and stored frozen for future use; and the competition incubation is overnight and is followed only by a brief colour development stage of 10 min. Coefficients of variation (CVs) of duplicate samples were similar to 5%, and mean response variances of untreated cattle (n = 57) were small (CV, 10%). Partitioning of variance showed 77% of this variability to be intrinsic to the samples, and the remaining 23% was due to the procedure. The limit of detection was approximately 0.5 ng ml(-1), which was considered to be satisfactory for the intended use of the method. The drug could be detected in serum of treated cattle for up to 10 weeks following treatment, and determinations showed a high level of reproducibility.
Resumo:
Solid-phase extraction (SPE) and direct competitive chemiluminescence enzyme immunoassay (dcCL-EIA) were combined for the detection of organophosphorus pesticides (OPs) in environmental water samples. dcCL-EIA based on horseradish peroxidase labeled with a broad-specificity monoclonal antibody against OPs was developed, and the effects of several physicochemical parameters on dcCL-EIA performance were studied. SPE was used for the pretreatment of water samples to remove interfering substances and to concentrate the OP analytes. The coupling of SPE and dcCL-EIA can detect seven OPs (parathion, coumaphos, phoxim, quinalphos, triazophos, dichlofenthion, and azinphos-ethyl) with the limit of quantitation below 0.1 ng/mL. The recoveries of OPs from spiked water samples ranged from 62.5% to 131.7% by SPE-dcCL-EIA and 69.5% to 112.3% by SPE-HPLC-MS/MS. The screening of OP residues in real-world environmental water samples by the developed SPE-dcCL-EIA and their confirmatory analysis using SPE-HPLC-MS/MS demonstrated that the assay is ideally suited as a monitoring method for OP residues prior to chromatographic analysis.
Resumo:
Background: Noroviruses (NoVs) are the most common cause of epidemic gastroenteritis, responsible for at least 50% of all gastroenteritis outbreaks worldwide and were recently identified as a leading cause of travelers' diarrhea (TD) in US and European travelers to Mexico, Guatemala, and India.
Methods: Serum and diarrheic stool samples were collected from 75 US student travelers to Cuernavaca, Mexico, who developed TD. NoV RNA was detected in acute diarrheic stool samples using reverse transcription-polymerase chain reaction (RT-PCR). Serology assays were performed using GI.1 Norwalk virus (NV) and GII.4 Houston virus (HOV) virus-like particles (VLPs) to measure serum levels of immunoglobulin A (IgA) and IgG by dissociation-enhanced lanthanide fluorescent immunoassay (DELFIA); serum IgM was measured by capture enzyme-linked immunosorbent assay (ELISA), and the 50% antibody-blocking titer (BT50 ) was determined by a carbohydrate-blocking assay.
Results: NoV infection was identified in 12 (16%; 9 GI-NoV and 3 GII-NoV) of 75 travelers by either RT-PCR or fourfold or more rise in antibody titer. Significantly more individuals had detectable preexisting IgA antibodies against HOV (62/75, 83%) than against NV (49/75, 65%) (p = 0.025) VLPs. A significant difference was observed between NV- and HOV-specific preexisting IgA antibody levels (p = 0.0037), IgG (p = 0.003), and BT50 (p = <0.0001). None of the NoV-infected TD travelers had BT50 > 200, a level that has been described previously as a possible correlate of protection.
Conclusion: We found that GI-NoVs are commonly associated with TD cases identified in US adults traveling to Mexico, and seroprevalence rates and geometric mean antibody levels to a GI-NoV were lower than to a GII-NoV strain.
Resumo:
Sedatives and tranquillisers are frequently used to reduce stress during the transportation of food producing animals. The most widely used classes of sedatives include the butyrophenone azaperone, the phenothiazines acepromazine, propionylpromazine, chlorpromazine and the beta-blocker, carazolol. For regulatory control purposes, tolerances for azaperone and carazolol have been set by the European Union as 100 and 25 mug kg(-1), respectively. Furthermore, the use of the phenothiazines is prohibited and therefore has a zero tolerance. A method for the detection of residues of five tranquillisers and one beta-blocker using a single ELISA plate has been developed. Kidney samples (2.5 g) were extracted with dichloromethane and applied to a competitive enzyme immunoassay using three polyclonal antibodies raised in rabbits against azaperol, propionylpromazine and carazolol conjugates. In sample matrix, the azaperol antibody cross-reacted 28.0% with azaperone and the propionylpromazine antibody cross-reacted 24.9% with acepromazine and 11.7% with chlorpromazine. In the ELISA, the detection capabilities of the six sedatives, azaperol, azaperone, carazolol, acepromazine, chlorpromazine, and propionylpromazine are 5, 15, 5, 5, 20 and 5 mug kg(-1), respectively. The proposed method is a sensitive and rapid multi-residue technique that offers a cost effective alternative to current published procedures, without any concession on the ability to detect sedative misuse.
Resumo:
Objective: A number of studies have shown an inverse association between infection with Helicobacter pylori and oesophageal adenocarcinoma (OAC). The mechanism of the apparent protection against OAC by H pylori infection and, in particular, the role of gastric atrophy is disputed. The relationship between all stages of the oesophageal inflammation, metaplasia, adenocarcinoma sequence and H pylori infection and gastric atrophy was explored. Methods: A case-control study involving 260 population controls, 227 OAC, 224 Barrett's oesophagus (BO) and 230 reflux oesophagitis (RO) patients recruited within Ireland was carried out. H pylori and CagA (cytotoxin-associated gene product A) infection was diagnosed serologically by western blot, and pepsinogen I and II levels were measured by enzyme immunoassay. Gastric atrophy was defined as a pepsinogen I/II ratio of <3. Results: H pylori seropositive was inversely associated with OAC, BO and RO; adjusted ORs (95% CIs), 0.49 (0.31 to 0.76), 0.35 (0.22 to 0.56) and 0.42 (0.27 to 0.65), respectively. Gastric atrophy was uncommon (5.3% of all subjects), but was inversely associated with non-junctional OAC, BO and RO; adjusted ORs (95% CIs), 0.34 (0.10 to 1.24), 0.23 (0.05 to 0.96) and 0.27 (0.08 to 0.88), respectively. Inverse associations between H pylori and the disease states remained in gastric atrophy-negative patients. Conclusion: H pylori infection and gastric atrophy are associated with a reduced risk of OAC, BO and RO. While use of the pepsinogen I/II ratio as a marker for gastric atrophy has limitations, these data suggest that although gastric atrophy is involved it may not fully explain the inverse associations observed with H pylori infection.
Resumo:
The use of cortisol levels as a measure of stress is often complicated by the use of invasive techniques that may increase hypothalamic-pituitary-adrenal (HPA) axis activity during sample collection. The goal of this study was to collect samples noninvasively and validate an enzyme-immunoassay (EIA) for the measurement of cortisol in urine to quantify HPA axis activity in the bearded emperor tamarin (Saguinus imperator subgrisescens). Urine samples were collected from trained subjects between 0700 and 0730 hr during a 1-month period, and were pooled for immunological validation. We validated the assay immunologically by demonstrating specificity, accuracy, precision, and sensitivity. For biological validation of the assay, we showed that levels of urinary cortisol (in samples collected between 0700 and 1700 hr) varied significantly across the day. Cortisol concentration was lowest at 0700 hr, increased to a mid-morning peak (0900 hr), and declined across the remainder of the day in a typical mammalian circadian pattern. We thus demonstrate that urinary cortisol can be used to quantify HPA activity in S. i. subgrisescens. (C) 2004 Wiley-Liss, Inc.
Resumo:
Micro-and nanoparticles prepared front the biodegradable and biocompatible polymers poly(lactide-co-glycolide) (PLGA) and polymetylmethacrylate (PMMA) have been successfully used as immunopotentiating antigen delivery systems. In our study, this approach was used to improve polyclonal antibody production to clenbuterol (CBL), a model hapten. PLGA and PMMA nanoparticles were loaded with either CBL alone or with a clenbuterol-transferrin conjugate (CBL-Tfn) and administered subcutaneously to mice. PLGA nano-particles were administered with or without the saponin adjuvant Quil A. The anti-CBL titres present in experimental sera were determined by an enzyme immunoassay (ELISA). CBL-Tfn-loaded PLGA nanoparticles co-administered with Quil A had obvious advantages immmunologically over the currently used method of raising antibodies to CBL (the positive control). The combined adjuvanticity of Quil A and PLGA nanoparticles resulted in a positive response in all four of the mice tested and in higher antibody titles than were seen in the positive control group. Furthermore, the sustained release of immunogen from the nanoparticles permitted a reduction in immunizing frequency over the 15-week study period.
Resumo:
Reports of the illegal use of clenbuterol as a growth promotant prompted the development of a competitive enzyme immunoassay for this drug. This procedure was utilized to study the elimination of clenbuterol from tissues in sheep medicated with both therapeutic and growth-promoting doses of the drug. The results indicated that prior to removal of medication clenbuterol was widely distributed throughout the animal tissues. However as the withdrawal periods increased fluid targets such as urine and bile became less effective at detecting clenbuterol usage. At both therapeutic and growth-enhancing concentrations of clenbuterol liver samples remained positive up to the maximum withdrawal time given in this experiment (15 days). Concentrations of clenbuterol likely to cause food poisoning (> 100 ng/g) were only detected in liver samples taken prior to the removal of medication. The highest recorded concentration of clenbuterol in muscle was 22.5 ng/g.