3 resultados para BIASED MONTE CARLO


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gold nanoparticles (GNPs) have shown potential to be used as a radiosensitizer for radiation therapy. Despite extensive research activity to study GNP radiosensitization using photon beams, only a few studies have been carried out using proton beams. In this work Monte Carlo simulations were used to assess the dose enhancement of GNPs for proton therapy. The enhancement effect was compared between a clinical proton spectrum, a clinical 6 MV photon spectrum, and a kilovoltage photon source similar to those used in many radiobiology lab settings. We showed that the mechanism by which GNPs can lead to dose enhancements in radiation therapy differs when comparing photon and proton radiation. The GNP dose enhancement using protons can be up to 14 and is independent of proton energy, while the dose enhancement is highly dependent on the photon energy used. For the same amount of energy absorbed in the GNP, interactions with protons, kVp photons and MV photons produce similar doses within several nanometers of the GNP surface, and differences are below 15% for the first 10 nm. However, secondary electrons produced by kilovoltage photons have the longest range in water as compared to protons and MV photons, e.g. they cause a dose enhancement 20 times higher than the one caused by protons 10 μm away from the GNP surface. We conclude that GNPs have the potential to enhance radiation therapy depending on the type of radiation source. Proton therapy can be enhanced significantly only if the GNPs are in close proximity to the biological target.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The measurement of fast changing temperature fluctuations is a challenging problem due to the inherent limited bandwidth of temperature sensors. This results in a measured signal that is a lagged and attenuated version of the input. Compensation can be performed provided an accurate, parameterised sensor model is available. However, to account for the in influence of the measurement environment and changing conditions such as gas velocity, the model must be estimated in-situ. The cross-relation method of blind deconvolution is one approach for in-situ characterisation of sensors. However, a drawback with the method is that it becomes positively biased and unstable at high noise levels. In this paper, the cross-relation method is cast in the discrete-time domain and a bias compensation approach is developed. It is shown that the proposed compensation scheme is robust and yields unbiased estimates with lower estimation variance than the uncompensated version. All results are verified using Monte-Carlo simulations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The measurement of fast changing temperature fluctuations is a challenging problem due to the inherent limited bandwidth of temperature sensors. This results in a measured signal that is a lagged and attenuated version of the input. Compensation can be performed provided an accurate, parameterised sensor model is available. However, to account for the influence of the measurement environment and changing conditions such as gas velocity, the model must be estimated in-situ. The cross-relation method of blind deconvolution is one approach for in-situ characterisation of sensors. However, a drawback with the method is that it becomes positively biased and unstable at high noise levels. In this paper, the cross-relation method is cast in the discrete-time domain and a bias compensation approach is developed. It is shown that the proposed compensation scheme is robust and yields unbiased estimates with lower estimation variance than the uncompensated version. All results are verified using Monte-Carlo simulations.