12 resultados para Antonin Artaud. Performatic Staging. Performance. Infection.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work ROTATING BRAINS / BEATING HEART was specifically developed for the opening performance of the 2010 DRHA conference. The conference’s theme ‘Sensual Technologies: Collaborative Practices of Interdisciplinarity explored collaborative relationships between the body and sensual/sensing technologies across various disciplines, looking to new approaches offered by various emerging fields and practices that incorporate new and existing technologies. The conference had a specific focus on SecondLife with roundtable events and discussions, led by performance artist Stelarc, as well as international participation via SecondLife.
The collaboration between Stelarc, the Avatar Orchestra Metaverse (AOM) and myself as the DRHA2010 conference program chair was a unique occurrence for this conference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose Efforts to prevent infection of arthroplasties, including the use of antibiotic-loaded bone cement, are not always successful. We investigated whether the incorporation of chitosan in gentamicin-loaded bone cement increases antibiotic release, and prevents bacterial adherence and biofilm formation by clinical isolates of Staphylococcus spp. In addition, we performed mechanical and degradation tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article examines two metatheatrical plays written by playwrights from the north of Ireland that bookend the twentieth century. The first is Ulster Literary Theatre (ULT) playwright Gerald MacNamara’s parodic, “proto-Pirandellian”4 The Mist That Does Be on the Bog (1909), which satirizes the peasant aesthetic of the “Abbey play” of the Irish Revival.5 The second is Marie Jones’s international hit, Stones in His Pockets (1999), a “play-full,” postmodern deconstruction of the commodification of Irish culture in the era of the Celtic Tiger. Although separated by exactly ninety years, the two plays can be connected through their critiques of the cultural politics of nationalism and globalization during the periods of the Irish Revival and the Celtic Tiger, respectively. Moreover, both plays are distinguished by their dramaturgical form, as the political critique of each is corporeally embodied in metatheatrical performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 196 (70.0%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 78 M. bovis positive lymph node samples (26 (12.6%) VL and 54 (73.0%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 73% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle.. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A quantitative duplex time-resolved fluorescence assay, dissociation-enhanced lanthanide fluorescent immunoassay (DELFIA), was developed to measure Norwalk virus (NV)-specific IgA and IgG antibodies simultaneously. The duplex assay showed superior performance by detecting seroconversion following experimental NV infection at an earlier time point than a reference total immunoglobulin enzyme-linked immunosorbent assay (ELISA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hospital-acquired infections pose both a major risk to patient wellbeing and an economic burden on global healthcare systems, with the problem compounded by the emergence of multidrug resistant and biocide tolerant bacterial pathogens. Many inanimate surfaces can act as a reservoir for infection, and adequate disinfection is difficult to achieve and requires direct intervention. In this study we demonstrate the preparation and performance of materials with inherent photodynamic, surface-active, persistent antimicrobial properties through the incorporation of photosensitizers into high density poly(ethylene) (HDPE) using hot-melt extrusion, which require no external intervention except a source of visible light. Our aim is to prevent bacterial adherence to these surfaces and eliminate them as reservoirs of nosocomial pathogens, thus presenting a valuable advance in infection control. A two-layer system with one layer comprising photosensitizer-incorporated HDPE, and one layer comprising HDPE alone is also described to demonstrate the versatility of our approach. The photosensitizer-incorporated materials are capable of reducing the adherence of viable bacteria by up to 3.62 Log colony forming units (CFU) per square centimeter of material surface for methicillin resistant Staphylococcus aureus (MRSA), and by up to 1.51 Log CFU/cm2 for Escherichia coli. Potential applications for the technology are in antimicrobial coatings for, or materials comprising objects, such as tubing, collection bags, handrails, finger-plates on hospital doors, or medical equipment found in the healthcare setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of biosensors attached to the body for health monitoring is now readily accepted, and the merits of such systems and their potential impact on healthcare receive much attention. Wearable medical systems used in clinical applications to monitor vital signs must be comfortable to wear, yet have robust performance to ensure reliable communications links. Additionally, and vital to the success of these innovations, is that these solutions are disposable to avoid risk of patient infection and this means that they must be ultra-low cost. Antennas optimized for printing using conductive inks offer new exciting advances in making a truly disposable solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. 

Objective: Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. 

Design: Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. 

Setting: Critical care departments within NHS hospitals in the north-west of England. 

Participants: Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. 

Main outcome measures: SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. 

Results: Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4–16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. 

Conclusion: SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare the use of a generic molecular assay to 'standard' investigations used to assist the diagnosis of late onset bacterial sepsis in very low birth weight infants (VLBW, <1500g).

METHODS: VLBW infants, greater than 48 hours of age, who were clinically suspected to have sepsis were investigated using standard tests (full blood count, C-reactive protein (at presentation) and blood culture), in addition, blood was taken for a universal molecular assay (16S rRNA reverse transcriptase PCR) for comparison. Clinical data were recorded during the suspected infection episode. A validated sepsis score (NEO-KISS) was used to retrospectively determine the presence of sepsis (independent of blood culture). The performance of each of the tests were compared by sensitivity, specificity, positive/negative likihood ratios (+/-LR) and postive/negative predictive values (PPV/NPV).

RESULTS: Sixty-five babies with suspected clinical sepsis were prospectively included. The performance indicators are presented with 95% confidence limits. For the detection of bacteria, blood culture had sensitivity of 0.57 (0.34-0.78), specificity of 0.45 (0.30-0.61); +LR of 1.05 (0.66-1.66) and-LR of 0.94 (0.52-1.7); PPV of 33.3 (18.56-50.97) and NPV of 68.97 (49.17-87.72). Serum CRP had sensitivity of 0.92 (0.64-1) and specificity of 0.36 (0.17-0.59); +LR of 1.45 (1-2.1) and-LR of 0.21 (0.03-1.5); PPV of 44.46 (26.6-66.6) and NPV of 88.9 (51.8-99.7). The universal molecular assay had sensitivity of 0.76 (0.53-0.92), specificity of 0.95 (0.85-0.99); +LR of 16.8 (4.2-66.3) and-LR of 0.25 (0.1-0.5); PPV of 88.9 (65.3-98.6) and NPV of 89.4 (76.9-96.5).

CONCLUSIONS: In VLBW infants this universal molecular assay performed better in the diagnosis of late onset sepsis (LOS) than blood culture and CRP. Further development is required to explore and improve the performance of the assay in real-time diagnosis.