80 resultados para Analyst


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The number of children identified as having intellectual or developmental disability is rising worldwide and their education has been found wanting. It has been said that “they simply need better teaching.” At the same time, there is an increasing evidence base that pedagogy that is based on the discipline of behaviour analysis offers the best prospect for individuals diagnosed with autism spectrum disorders. On the basis of this evidence, it is proposed that behaviour analysis should be applied more broadly to improve teaching for all children with intellectual or developmental disability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper Bereavement: A behavioural process (Dillenburger & Keenan, 1994) was first published within a vacuum of behaviour analytic thinking or research in this field. The paper was meant to be a first step in stimulating others to contribute to the understanding of one of the most complex, yet most universal, human behavioural processes. The only behaviour analyst addressing the issues directly was Calkin (1990). Recently, after reading our original 1994 paper, Beth Sulzer-Azaroff suggested that we should solicit comments directly from the behaviour analytic community. This we did with the help of Erik Arntzen and now the reprint and the commentaries in this edition of the European Journal of Behaviour Analysis (EJBA) fully embrace and extend the contribution of behaviour analysis to the understanding of the behavioural process that is bereavement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The production of an antibody to detect toltrazuril or its metabolite ponazuril is complicated due to structural constraints of conjugating these coccidiostats to a carrier protein. Therefore a search was carried out for a compound that shared a common substructure to use as an antigen mimic. The chosen compound, trifluoraminoether, was conjugated to two carrier proteins (HSA and BTG) and used in the immunisation of six rabbits. Two immunogen doses (1 mg and 0.1 mg) were also used. All six rabbits produced an immunological response to the hapten regardless of the carrier protein or immunogen dose used. The most sensitive polyclonal antibody produced, designated R609, was subsequently characterised. This antiserum exhibited an IC50 of 18 ng ml-1 using a competitive ELISA format. Cross reactivity studies show that this serum is specific for toltrazuril and its metabolites (toltrazuril sulfoxide and toltrazuril sulfone) but does not cross-react with other coccidiostats such as halofuginone, nitroimidazoles or nicarbazin. This is the first reported production of an antibody capable of specifically binding toltrazuril and ponazuril.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sedatives and tranquillisers are frequently used to reduce stress during the transportation of food producing animals. The most widely used classes of sedatives include the butyrophenone azaperone, the phenothiazines acepromazine, propionylpromazine, chlorpromazine and the beta-blocker, carazolol. For regulatory control purposes, tolerances for azaperone and carazolol have been set by the European Union as 100 and 25 mug kg(-1), respectively. Furthermore, the use of the phenothiazines is prohibited and therefore has a zero tolerance. A method for the detection of residues of five tranquillisers and one beta-blocker using a single ELISA plate has been developed. Kidney samples (2.5 g) were extracted with dichloromethane and applied to a competitive enzyme immunoassay using three polyclonal antibodies raised in rabbits against azaperol, propionylpromazine and carazolol conjugates. In sample matrix, the azaperol antibody cross-reacted 28.0% with azaperone and the propionylpromazine antibody cross-reacted 24.9% with acepromazine and 11.7% with chlorpromazine. In the ELISA, the detection capabilities of the six sedatives, azaperol, azaperone, carazolol, acepromazine, chlorpromazine, and propionylpromazine are 5, 15, 5, 5, 20 and 5 mug kg(-1), respectively. The proposed method is a sensitive and rapid multi-residue technique that offers a cost effective alternative to current published procedures, without any concession on the ability to detect sedative misuse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When attempting to quantify the volatile components of a food isolated by dynamic headspace trapping onto an adsorbent, the analyst has to select the most appropriate compounds to use as standards and at which stage of the analysis to add them. Factors to be borne in mind include the volatility of the standard, the response of the GC detector, and whether to add the standard to the sample or to the adsorbent trap. This chapter considers the issues and describes the application of one chosen method to the quantitation of the volatile components of baked potato.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-Ray Photoelectron Spectroscopy (XPS) was used to quantify the amount of bromide ions present in two samples of [C(4)mpyrr]Br dissolved in the room temperature ionic liquid (RTIL) [C(4)mpyrr][N(Tf)(2)]. One sample was of a known concentration (0.436 Br atom%); the other was a saturated solution. The results obtained from quantitative XPS analysis indicated that the saturated sample had a concentration, or solubility, of 0.90 Br atom% (746 mM) at 298 K, which was then independently confirmed by potential-step chronoamperometry of the same solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dipicolinic acid (DPA) is an excellent marker compound for bacterial spores, including those of Bacillus anthracis ( anthrax). Surface-enhanced Raman spectroscopy (SERS) potentially has the sensitivity and discrimination needed for trace DPA analysis, but mixing DPA solutions with citrate-reduced silver colloid only yielded measurable SERS spectra at much higher (> 80 ppm) concentrations than would be desirable for anthrax detection. Aggregation of the colloid with halide salts eliminated even these small DPA bands but aggregation with Na2SO4(aq) resulted in a remarkable increase in the DPA signals. With sulfate aggregation even 1 ppm solutions gave detectable signals with 10 s accumulation times, which is in the sensitivity range required. Addition of CNS- as an internal standard allowed quantitative DPA analysis, plotting the intensity of the strong DPA 1010 cm(-1) band (normalised to the ca. 2120 cm(-1) CNS- band) against DPA concentration gave a linear calibration (R-2 = 0.986) over the range 0 - 50 ppm DPA. The inclusion of thiocyanate also allows false negatives due to accidental deactivation of the enhancing medium to be detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid, quantitative SERS analysis of nicotine at ppm/ppb levels has been carried out using stable and inexpensive polymer-encapsulated Ag nanoparticles (gel-colls). The strongest nicotine band (1030 cm(-1)) was measured against d(5)-pyridine internal standard (974 cm(-1)) which was introduced during preparation of the stock gel-colls. Calibration plots of I-nic/I-pyr against the concentration of nicotine were non-linear but plotting I-nic/I-pyr against [nicotine](x) (x = 0.6-0.75, depending on the exact experimental conditions) gave linear calibrations over the range (0.1-10 ppm) with R-2 typically ca. 0.998. The RMS prediction error was found to be 0.10 ppm when the gel-colls were used for quantitative determination of unknown nicotine samples in 1-5 ppm level. The main advantages of the method are that the gel-colls constitute a highly stable and reproducible SERS medium that allows high throughput (50 sample h(-1)) measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large numbers of identical and stable SE(R)RS [surface-enhanced (resonance) Raman]-active media, which are convenient to handle and manipulate but sufficiently inexpensive that they can be used once and then discarded, have been prepared by isolating nanoparticles from Ag and Au sols in hydrophilic polymer gels. The preparation simply involves mixing a suitable polymer with the sol to give a viscous suspension that can be coated onto a substrate and dried to form a hard translucent film. The films remain inactive until they are treated with aqueous analyte solution, which causes the film to swell and brings the analyte into contact with the active metal particles. The swollen films give strong SERS spectra which are effectively identical to those obtained from simple sols. The advantage of this method is that the dried polymers can be stored indefinitely before use and that they give a high degree of spectral reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monolithic catalysts are widely used as structured catalysts, especially in the abatement of pollutants. Probing what happens inside these monoliths during operation is, therefore, vital for modelling and prediction of the catalyst behavior. SpaciMS is a spatially resolved capillary-inlet mass spectroscopy system allowing for the generation of spatially resolved maps of the reactions within monoliths. In this study SpaciMS results combined with 3D CFD modelling demonstrate that SpaciMS is a highly sensitive and minimally invasive technique that can provide reaction maps as well as catalytic temporal behavior. Herein we illustrate this by examining kinetic oscillations during a CO oxidation reaction over a Pt/Rh on alumina catalyst supported on a cordierite monolith. These oscillations were only observed within the monolith by SpaciMS between 30 and 90% CO conversion. Equivalent experiments performed in a plug-flow reactor using this catalyst in a crushed form over a similar range of reaction conditions did not display any oscillations demonstrating the importance of intra monolith analysis. This work demonstrates that the SpaciMS offers an accurate and comprehensive picture of structured catalysts under operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the formation of highly scattering silver complexes of adenine, deoxyadenosine and 5'-dAMP under alkaline pH conditions in the colloidal silver solutions which are used for surface-enhanced Raman spectroscopy. These complexes, and other pH-dependent phenomena, help to explain the diversity of previously reported adenine SERS spectra. Using conditions which promote complex formation allows nucleotides to be detected at <1 ppm, even in solutions with high salt concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for rapid analysis of unextracted poultry plasma samples has been developed based on a novel immunoassay format: one-step all-in-one dry reagent time resolved fluorimetry. All assay specific components were pre-dried onto microtitration plate wells. Only addition of the serum sample diluted in assay buffer was required to perform analysis. Results were available one hour after sample addition. The limit of detection (mean + 3s) of the assay calculated from the analysis of 23 known negative samples was 14.2 ng ml(-1). Intra- and inter-assay RSD were determined as 15.2 and 7.4%, respectively, using a plasma sample fortified with 50 ng ml(-1) monensin. Eight broiler chickens were fed monensin at a dose rate of 120 mg kg(-1) feed for one week, blood sampled then slaughtered without drug withdrawal. Plasma monensin concentrations, as determined by the fluoroimmunoassay ranged from 101-297 ng ml(-1). This compared with monensin liver concentrations, determined by LC-MS, which ranged fi om 13-41 ng g(-1). The fluoroimmunoassay described is extremely user friendly, gives particularly rapid results and is suitable for the detection and quantification of plasma monensin residues. Data from medicated poultry suggest that analysis of plasma may be useful in predicting the extent of monensin liver residues.