2 resultados para vertical wind shear

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports an experimental study in which samples of soft kaolin clay (100 mm in diameter and 200 mm in height) were reinforced with vertical columns of sand and tested under triaxial conditions. Samples were reinforced with either a single column of sand of 32 mm diameter or three columns of sand, each of 20 mm diameter. The replacement method was used to form the columns. The columns were installed in the clay to depths of 120 and 200 mm. Tests were also carried out on samples that were not reinforced with sand columns. The samples were compressed under both drained and undrained conditions. It was found that the undrained shear strength of samples containing full-depth columns was greatly improved compared with that of the unreinforced samples. In the fully drained tests, the sample installed with a single column of 32 mm diameter exhibited better performance than the sample with three columns of 20 mm diameter, although the area replacement ratio in the case of the three 20 mm diameter columns was higher than that of the single 32 mm diameter column. However, the undrained strength of the composite material was not particularly affected by the number of columns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Composite beams with large web openings are often used, and their design is controlled by Vierendeel bending at the four corners of each opening, which is assisted by local composite action with the floor slab. Development of this Vierendeel bending resistance may be limited by pull-out failure of the shear connectors. In this paper, a non-linear elasto-plastic finite element model of a composite beam with web openings was used to investigate this mode of pull-out failure. A test was performed on a typical composite slab in which the shear connectors were subject to pure tension and the failure load was 67 kN, which is approximately 70% of the longitudinal shear resistance. The results of the finite element model are compared against those obtained using the established design theory, that does not limit the vertical pull-out resistance of the shear connectors. It is shown that the local bending resistance due to composite action should be reduced when limited by pull-out of the shear connectors. A parametric study investigated the effect of openings of 600 to 1200 mm length. A simple model is developed to establish the Vierendeel bending resistance, when limited by pull-out of the shear connectors.