7 resultados para testing tools

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The simultaneous heat and moisture transfer in the building envelope has an important influence on the indoor environment and the overall performance of buildings. In this paper, a model for predicting whole building heat and moisture transfer was presented. Both heat and moisture transfer in the building envelope and indoor air were simultaneously considered; their interactions were modeled. The coupled model takes into account most of the main hygrothermal effects in buildings. The coupled system model was implemented in MATLAB-Simulink, and validated by using a series of published testing tools. The new program was applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption under different climates. The results show that the use of more detailed simulation routines can result in improvements to the building's design for energy optimisation through the choice of proper hygroscopic materials, which would not be indicated by simpler calculation techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab–Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Seafloor massive sulfide (SMS) mining will likely occur at hydrothermal systems in the near future. Alongside their mineral wealth, SMS deposits also have considerable biological value. Active SMS deposits host endemic hydrothermal vent communities, whilst inactive deposits support communities of deep water corals and other suspension feeders. Mining activities are expected to remove all large organisms and suitable habitat in the immediate area, making vent endemic organisms particularly at risk from habitat loss and localised extinction. As part of environmental management strategies designed to mitigate the effects of mining, areas of seabed need to be protected to preserve biodiversity that is lost at the mine site and to preserve communities that support connectivity among populations of vent animals in the surrounding region. These "set-aside" areas need to be biologically similar to the mine site and be suitably connected, mostly by transport of larvae, to neighbouring sites to ensure exchange of genetic material among remaining populations. Establishing suitable set-asides can be a formidable task for environmental managers, however the application of genetic approaches can aid set-aside identification, suitability assessment and monitoring. There are many genetic tools available, including analysis of mitochondrial DNA (mtDNA) sequences (e.g. COI or other suitable mtDNA genes) and appropriate nuclear DNA markers (e.g. microsatellites, single nucleotide polymorphisms), environmental DNA (eDNA) techniques and microbial metagenomics. When used in concert with traditional biological survey techniques, these tools can help to identify species, assess the genetic connectivity among populations and assess the diversity of communities. How these techniques can be applied to set-aside decision making is discussed and recommendations are made for the genetic characteristics of set-aside sites. A checklist for environmental regulators forms a guide to aid decision making on the suitability of set-aside design and assessment using genetic tools. This non-technical primer document represents the views of participants in the VentBase 2014 workshop.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a protocol for the generation and validation of bacteria microarrays and their application to the study of specific features of the pathogen's surface and interactions with host receptors. Bacteria were directly printed on nitrocellulose-coated glass slides, using either manual or robotic arrayers, and printing quality, immobilization efficiency and stability of the arrays were rigorously controlled by incorporating a fluorescent dye into the bacteria. A panel of wild type and mutant strains of the human pathogen Klebsiella pneumoniae, responsible for nosocomial and community-acquired infections, was selected as model bacteria, and SYTO-13 was used as dye. Fluorescence signals of the printed bacteria were found to exhibit a linear concentration-dependence in the range of 1 x 10(8) to 1 x 10(9) bacteria per ml. Similar results were obtained with Pseudomonas aeruginosa and Acinetobacter baumannii, two other human pathogens. Successful validation of the quality and applicability of the established microarrays was accomplished by testing the capacity of the bacteria array to detect recognition by anti-Klebsiella antibodies and by the complement subcomponent C1q, which binds K. pneumoniae in an antibody-independent manner. The biotin/AlexaFluor-647-streptavidin system was used for monitoring binding, yielding strain-and dose-dependent signals, distinctive for each protein. Furthermore, the potential of the bacteria microarray for investigating specific features, e.g. glycosylation patterns, of the cell surface was confirmed by examining the binding behaviour of a panel of plant lectins with diverse carbohydrate-binding specificities. This and other possible applications of the newly developed arrays, as e.g. screening/evaluation of compounds to identify inhibitors of host-pathogen interactions, make bacteria microarrays a useful and sensitive tool for both basic and applied research in microbiology, biomedicine and biotechnology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent research has shown that higher ambient turbulence leads to better wake recovery, so turbines could be installed in closer proximity in real tidal flows than might be assumed from typical towing tank tests that do not take into account turbulent inflow conditions. The standard tools to assess flow velocities in field conditions are Doppler based sonar devices, such as Acoustic Doppler Profilers (ADPs) or Acoustic Doppler Velocimeters (ADVs). The use of these devices poses some challenges when assessing the wake of a tidal turbine. While ADPs allow the three-dimensional measurement of a velocity profile over a distance, the data is calculated as a mean of three diverging beams and with low temporal resolution. ADVs can measure with higher sampling frequency but only at a single point in the flow. During the MaRINET testing of the SCHOTTELSIT turbine at the QUB tidal test site in Portaferry, Northern Ireland, ADP and ADV measurements were successfully tested.Two methods were employed for measuring the wake: firstly, with a rigidly mounted ADP and secondly, with a submerged ADV which was streamed behind the turbine. This paper presents the experimental set-up and results and discusses limitations and challenges of the two methods used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real-space grids are a powerful alternative for the simulation of electronic systems. One of the main advantages of the approach is the flexibility and simplicity of working directly in real space where the different fields are discretized on a grid, combined with competitive numerical performance and great potential for parallelization. These properties constitute a great advantage at the time of implementing and testing new physical models. Based on our experience with the Octopus code, in this article we discuss how the real-space approach has allowed for the recent development of new ideas for the simulation of electronic systems. Among these applications are approaches to calculate response properties, modeling of photoemission, optimal control of quantum systems, simulation of plasmonic systems, and the exact solution of the Schrödinger equation for low-dimensionality systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: It is important to assess the clinical competence of nursing students to gauge their educational needs. Competence can be measured by self-assessment tools; however, Anema and McCoy (2010) contend that currently available measures should be further psychometrically tested.
Aim: To test the psychometric properties of Nursing Competencies Questionnaire (NCQ) and Self-Efficacy in Clinical Performance (SECP) clinical competence scales.
Method: A non-randomly selected sample of n=248 2nd year nursing students completed NCQ, SECP and demographic questionnaires (June and September 2013). Mokken Scaling Analysis (MSA) was used to investigate structural validity and scale properties; convergent and discriminant validity and reliability were also tested for each scale.
Results: MSA analysis identified that the NCQ is a unidimensional scale with strong scale scalability coefficients Hs =0.581; but limited item rankability HT =0.367. The SECP scale MSA suggested that the scale could be potentially split into two unidimensional scales (SECP28 and SECP7), each with good/reasonable scalablity psychometric properties as summed scales but negligible/very limited scale rankability (SECP28: Hs = 0.55, HT=0.211; SECP7: Hs = 0.61, HT=0.049). Analysis of between cohort differences and NCQ/SECP scores produced evidence of discriminant and convergent validity; good internal reliability was also found: NCQ α = 0.93, SECP28 α = 0.96 and SECP7 α=0.89.

Discussion: In line with previous research further evidence of the NCQ’s reliability and validity was demonstrated. However, as the SECP findings are new and the sample small with reference to Straat and colleagues (2014), the SECP results should be interpreted with caution and verified on a second sample.
Conclusions: Measurement of perceived self-competence could start early in a nursing programme to support students’ development of clinical competence. Further testing of the SECP scale with larger nursing student samples from different programme years is indicated.

References:
Anema, M., G and McCoy, JK. (2010) Competency-Based Nursing Education: Guide to Achieving Outstanding Learner Outcomes. New York: Springer.
Straat, JH., van der Ark, LA and Sijtsma, K. (2014) Minimum Sample Size Requirements for Mokken Scale Analysis Educational and Psychological Measurement 74 (5), 809-822.