9 resultados para system improvements

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The environmental attractions of air-cycle refrigeration are considerable. Following a thermodynamic design analysis, an air-cycle demonstrator plant was constructed within the restricted physical envelope of an existing Thermo King SL200 trailer refrigeration unit. This unique plant operated satisfactorily, delivering sustainable cooling for refrigerated trailers using a completely natural and safe working fluid. The full load capacity of the air-cycle unit at -20 °C was 7,8 kW, 8% greater than the equivalent vapour-cycle unit, but the fuel consumption of the air-cycle plant was excessively high. However, at part load operation the disparity in fuel consumption dropped from approximately 200% to around 80%. The components used in the air-cycle demonstrator were not optimised and considerable potential exists for efficiency improvements, possibly to the point where the air-cycle system could rival the efficiency of the standard vapour-cycle system at part-load operation, which represents the biggest proportion of operating time for most units.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigates the use of co-melt fluidised bed granulation for the agglomeration of model pharmaceutical powders, namely, lactose mono-hydrate, PEG 10000, poly-vinyl pyrolidone and ibuprofen as a model drug. Granulation within the co-melt system was found to follow a nucleationâ??steady growthâ??coating regime profile. Using high molecular weight PEG binder, the granulation mechanism and thus the extent of granulation was found to be significantly influenced by binder viscosity. The compression properties of the granulate within the hot fluidised bed were correlated using a novel high temperature experimental procedure. It was found that the fracture stress and fractural modulus of the materials under hot processing conditions were orders of magnitude lower than those measured under ambient conditions. A range of particle velocities within the granulator were considered based on theoretical models. After an initial period of nucleation, the Stokes deformation number analysis indicated that only velocities within the high shear region of the fluidised bed were sufficient to promote significant granule deformation and therefore, coalescence. The data also indicated that larger granules de-fluidised preventing agglomeration by coalescence. Furthermore, experimental data indicated that dissipation of the viscous molten binder to the surface was the most important factor in the latter stages of the granulation process. From a pharmaceutical perspective the inclusion of the model drug, ibuprofen, combined with PVP in the co-melt process proved to be highly significant. It was found that using DSC analysis on the formulations that the decrease in the heat of fusion associated with the melting of ibuprofen within the FHMG systems may be attributed to interaction between PVP and ibuprofen through inter-molecular hydrogen bonding. This interaction decreases the crystallinity of ibuprofen and facilitates solubilisation and bioavailability within the solid matrix.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background This paper assesses the usefulness of the Child Health Computing System as a source of information about children with cerebral palsy.

Methods A comparative survey of information held on the Child Health Computing System (CHCS) and the Northern Ireland Cerebral Palsy Register (NICPR) in one Health and Social Services Board in Northern Ireland was carried out. The sample comprised children with cerebral palsy aged 5–9 years.

Results Of the 135 cases recorded on the NICPR, 47 per cent were not found on the CHCS; the majority of these children had no computer record of any medical diagnosis. Of the 82 cases recorded on the CHCS, 10(12 per cent) were not found on the NICPR; five of these cases (6 per cent) were found on follow–up not to have CP.

Conclusions Unless improvements are made in case ascertainment, case validation and recording activities, the evidence suggests that the CHCS will not be able to provide the same quality of information for needs assessment and surveillance of very low birthweight infants in relation to cerebral palsy as is provided by a specialist case register.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Constructed wetland systems (CWS) have been used as a low cost bio-filtration system to treat farm wastewater. While studies have shown that CWS are efficient in removing organic compounds and pathogens, there is limited data on the presence of hormones in this type of treatment system. The objective of this study was to evaluate the ability of the CWS to reduce estrogenic and androgenic hormone concentration in dairy wastewater. This was achieved through a year long study on dairy wastewater samples obtained froma surface flow CWS. Analysis of hormonal levels was performed using a solid phase extraction (SPE) sample clean-up method, combined with reporter gene assays (RGAs) which incorporate relevant receptors capable of measuring total estrogenic or androgenic concentrations as low as 0.24 ng L1 and 6.9 ng L1 respectively. Monthly analysis showed a mean removal efficiency for estrogens of 95.2%, corresponding to an average residual concentration of 3.2 ng L1 17b-estradiol equivalent (EEQ), below the proposed lowest observable effect concentration (LOEC) of 10 ng L1. However, for one month a peak EEQ concentration of 115 ng L1 was only reduced to 18.8 ng L1. The mean androgenic activity peaked at 360 ng L1 and a removal efficiency of 92.1% left an average residual concentration of 32.3 ng L1 testosterone equivalent (TEQ). The results obtained demonstrate that this type of CWS is an efficient system for the treatment of hormones in dairy wastewater. However, additional design improvements may be required to further enhance removal efficiency of peak hormone concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dynamic global security-aware synthesis flow using the SystemC language is presented. SystemC security models are first specified at the system or behavioural level using a library of SystemC behavioural descriptions which provide for the reuse and extension of security modules. At the core of the system is incorporated a global security-aware scheduling algorithm which allows for scheduling to a mixture of components of varying security level. The output from the scheduler is translated into annotated nets which are subsequently passed to allocation, optimisation and mapping tools for mapping into circuits. The synthesised circuits incorporate asynchronous secure power-balanced and fault-protected components. Results show that the approach offers robust implementations and efficient security/area trade-offs leading to significant improvements in turnover.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lung disease in cystic fibrosis (CF) is typified by the development of chronic airways infection culminating in bronchiectasis and progression to end-stage respiratory disease. Pseudomonas aeruginosa, a ubiquitous gram-negative bacteria, is the archetypical CF pathogen and is associated with an accelerated clinical decline. The development and widespread use of chronic suppressive aerosolized antibacterial therapies, in particular Tobramycin Inhalation Solution (TIS), in CF has contributed to reduced lung function decline and improved survival. However, the requirement for the aerosolization of these agents through nebulizers has been associated with increased treatment burden, reduced quality of life and remain a barrier to broader uptake. Tobramycin Inhalation Powder (TIP™) has been developed by Novartis with the express purpose of delivering the same benefits as TIS in a time-effective manner. Administered via the T-326™ (Novartis) Inhaler in four individual 28-mg capsules, TIP can be administered in a quarter of the time of traditional nebulizers and is inherently portable. In clinical studies, TIP has been shown to be safe, result in equivalent or superior reductions in P. aeruginosa sputum density and produce similar improvements in pulmonary function. TIP offers significant advantages in time saving, portability and convenience over traditional nebulized TIS with comparable clinical outcomes for individuals with CF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fate and cycling of two selected POPs is investigated for the North Sea system with an improved version of a fate and transport ocean model (FANTOM). The model uses atmospheric data from the EMEP MSC East POP model (Gusev et al., 2009), giving reasonable concentrations and seasonal distributions for the entire region, as opposed to the three observation stations that Ilyina et al. (2006) were limited to. Other model improvements include changes in the calculation of POP exchange between the water column and sediment.

We chose to simulate the fate of two POPs with very different properties, ?-HCH and PCB 153. Since the fate and cycling of POPs are strongly affected by hydrodynamic processes, a high resolution version of the Hamburg Shelf Ocean Model (HAMSOM) was developed and utilised. Simulations were made for the period 1996–2005. Both models were validated by comparing results with available data, which showed that the simulations were of very satisfactory quality.

Model results show that the North Sea is a net sink for ?-HCH and a net source to the atmosphere of PCB 153. Total masses of ?-HCH and PCB 153 in 2005 are reduced to 30% and 50%, respectively, of 1996 values.

Storms resuspending bottom sediments into the water column mobilise POPs into the atmosphere and have the potential to deliver substantial loads of these POPs into Europe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There have been over 3000 bridge weigh-in-motion (B-WIM) installations in 25 countries worldwide, this has led vast improvements in post processing of B-WIM systems since its introduction in the 1970’s. This paper introduces a new low-power B-WIM system using fibre optic sensors (FOS). The system consisted of a series of FOS which were attached to the soffit of an existing integral bridge with a single span of 19m. The site selection criteria and full installation process has been detailed in the paper. A method of calibration was adopted using live traffic at the bridge site and based on this calibration the accuracy of the system was determined.