89 resultados para suppression of Fermi acceleration
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Novel technology dependent scaling parameters i.e. spacer to gradient ratio and effective channel length (Leff) are proposed for source/drain engineered DG MOSFET, and their significance in minimizing short channel effects (SCES) in high-k gate dielectrics is discussed in detail. Results show that a high-k dielectric should be associated with a higher spacer to gradient ratio to minimise SCEs The analytical model agrees with simulated data over the entire range of spacer widths, doping gradients, high-k gate dielectrics and effective channel lengths.
Resumo:
The interaction of an intense laser field with a beam of atomic ions has been investigated experimentally for the first time. The ionization dynamics of Ar+ ions and Ar neutrals in a 60 fs, 790 nm laser pulse have been compared and contrasted at intensities up to 10(16) W cm (-2). Our results show that nonsequential ionization from an Ar+ target is strongly suppressed compared with that from the corresponding neutral target. We have also observed for the first time the strong field ionization of high lying target metastable levels in the Ar+ beam.
Resumo:
Three experiments examined the influence of a second rule on the pattern of card selections on Wason's selection task. In Experiment 1 participants received a version of the task with a single test rule or one of two versions of the task with the same original test rule together with a second rule. The probability of q was manipulated in the two-rules conditions by varying the size of the antecedent set in the second rule. The results showed a significant suppression of q card and not-p card selections in the alternative-rule conditions, but no difference as a function of antecedent set size. In Experiment 2 the size of the antecendent set in the two-rules conditions was manipulated using the context of a computer printing double-sided cards. The results showed a significant reduction of q card selections in the two-rules conditions, but no effect of p set size. In Experiment 3 the scenario accompanying the rule was manipulated, and it specified a single alternative antecedent or a number of alternative antecedents. The q card selection rates were not affected by the scenario manipulation but again were suppressed by the presence of a second rule. Our results suggest that people make inferences about the unseen side of the cards when engaging with the task and that these inferences are systematically influenced by the presence of a second rule, but are not influenced by the probabilistic characteristics of this rule. These findings are discussed in the context of decision theoretic views of selection task performance (Oaksford Chater, 1994).
Resumo:
The results of three experiments investigating the role of deductive inference in Wason's selection task are reported. In Experiment 1, participants received either a standard one-rule problem or a task containing a second rule, which specified an alternative antecedent. Both groups of participants were asked to select those cards that they considered were necessary to test whether the rule common to both problems was true or false. The results showed a significant suppression of q card selections in the two-rule condition. In addition there was weak evidence for both decreased p selection and increased not-q selection. In Experiment 2 we again manipulated number of rules and found suppression of q card selections only. Finally, in Experiment 3 we compared one- and two-rule conditions with a two-rule condition where the second rule specified two alternative antecedents in the form of a disjunction. The q card selections were suppressed in both of the two-rule conditions but there was no effect of whether the second rule contained one or two alternative antecedents. We argue that our results support the claim that people make inferences about the unseen side of the cards when engaging with the indicative selection task.
Resumo:
Low energy antiprotons have been used previously to give benchmark data for theories of atomic collisions. Here we present measurements of the cross section for single, nondissociative ionization of molecular hydrogen for impact of antiprotons with kinetic energies in the range 2-11 keV, i.e., in the velocity interval of 0.3-0.65 a.u. We find a cross section which is proportional to the projectile velocity, which is quite unlike the behavior of corresponding atomic cross sections, and which has never previously been observed experimentally.
Resumo:
The possibility of using high-power lasers to generate high-quality beams of energetic ions is attracting large global interest. The prospect of using laser-accelerated protons in medicine attracts particular interest, as these schemes may lead to compact and relatively low-cost sources. Among the challenges remaining before these sources can be used in medicine is to increase the numbers and energies of the ions accelerated. Here, we extend the energy and intensity range over which proton scaling is experimentally investigated, up to 400 J and 6 x 10(20) W cm(-2) respectively, and find a slower proton scaling than previously predicted. With the aid of plasma-expansion simulation tools, our results suggest the importance of time-dependent and multidimensional effects in predicting the maximum proton energy in this ultrahigh-intensity regime. The implications of our new understanding of proton scaling for potential medical applications are discussed.
Resumo:
Reduction of proton acceleration in the interaction of a high-intensity, picosecond laser with a 50-mu m aluminum target was observed when 0.1-6 mu m of plastic was deposited on the back surface (opposite side of the laser). The maximum energy and number of energetic protons observed at the back of the target were greatly reduced in comparison to pure aluminum and plastic targets of the same thickness. This is attributed to the effect of the interface between the layers. Modeling of the electron propagation in the targets using a hybrid code showed strong magnetic-field generation at the interface and rapid surface heating of the aluminum layer, which may account for the results. (c) 2006 American Institute of Physics.
Resumo:
Recent experiments using Terawatt lasers to accelerate protons deposited on thin wire targets are modeled with a new type of gridless plasma simulation code. In contrast to conventional mesh-based methods, this technique offers a unique capability in emulating the complex geometry and open-ended boundary conditions characteristic of contemporary experimental conditions. Comparisons of ion acceleration are made between the tree code and standard particle-in-cell simulations for a typical collisionless
Resumo:
Evidence is accumulating that irradiated cells produce some signals which interact with non-exposed cells in the same population via a bystander effect. Here, we examined whether DMSO is effective in suppressing radiation induced bystander effects in CHO and repair deficient xrs5 cells. When 1 Gy-irradiated CHO cells were treated with 0.5% DMSO for 1 hr before irradiation, the induction of micronuclei in irradiated cells was suppressed to 80% of that in non-treated irradiated cells. The suppressive effect of DMSO on the formation of bystander signals was examined and the results demonstrated that 0.5% DMSO treatment of irradiated cells completely suppressed the induction of micronuclei by the bystander effect in non-irradiated cells. It is suggested that irradiated cells ceased signal formation for bystander effects by the action of DMSO. To determine the involvement of reactive oxygen species on the formation of bystander signals, we examined oxidative stress levels using the DCFH staining method in irradiated populations. The results showed that the treatment of irradiated cells with 0.5% DMSO did not suppress oxidative stress levels. These results suggest that the prevention of oxidative stress is independent of the suppressive effect of DMSO on the formation of the bystander signal in irradiated cells. It is suggested that increased ROS in irradiated cells is not a substantial trigger of a bystander signal.