4 resultados para stimuli responsive materials

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulsatile, or “on-demand”, delivery systems have the capability to deliver a therapeutic molecule at the right time/site of action and in the right amount (1). Pulsatile delivery systems present multiple benefits over conventional dosage forms and provide higher patient compliance. The combination of stimuli-responsive materials with the drug delivery capabilities of hydrogel-forming MN arrays (2) opens an interesting area of research. In the present work we describe, a stimuli-responsive hydrogel-forming microneedle (MN) array that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of UV radiation (Figure 1A). MN arrays were prepared using a micromolding technique using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) (Figure 1B). The arrays were loaded with up to 5% (w/w) ibuprofen included in a light-responsible conjugate (3,5-dimethoxybenzoin conjugate) (2). The presence of the conjugate inside the MN arrays was confirmed by Raman spectroscopy measurements. MN arrays were tested in vitro showing that they were able to deliver up to three doses of 50 mg of ibuprofen after application of an optical trigger (wavelength of 365 nm) over a long period of time (up to 160 hours) (Figure 1C and 1D). The work presented here is a probe of concept and a modified version of the system should be used as UV radiation is shown to be the major etiologic agent in the development of skin cancers. Consequently, for future applications of this technology an alternative design should be developed. Based on the previous research dealing with hydrogel forming MN arrays a suitable strategy will be to use hydrogel-forming MN arrays containing a backing layer made with the material described in this work as the drug reservoir (2). Finally, a porous layer of a material that blocks UV radiation should be included between the MN array and the drug reservoir. Therefore radiation can be applied to the system without reaching the skin surface. Therefore after modification, the system described here interesting properties as “on-demand” release system for prolonged periods of time. This technology has potential for use in “on-demand” delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe, for the first time, stimuli-responsive hydrogel-forming microneedle (MN) arrays that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of light. MN arrays were prepared using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) by micromolding. The obtained MN arrays showed good mechanical properties. The system was loaded with up to 5% (w/w) ibuprofen included in a light-responsive 3,5-dimethoxybenzoin conjugate. Raman spectroscopy confirmed the presence of the conjugate inside the polymeric MN matrix. In vitro, this system was able to deliver up to three doses of 50 mg of ibuprofen upon application of an optical trigger over a prolonged period of time (up to 160 hours). This makes the system appealing as a controlled release device for prolonged periods of time. We believe that this technology has potential for use in ?on-demand? delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Importance of the field: Conventional dosing methods are frequently unable to deliver the clinical requirement of the patient. The ability to control the delivery of drugs from implanted materials is difficult to achieve, but offers promise in diverse areas such as infection-resistant medical devices and 10 responsive implants for diabetics. Areas covered in this review: This review gives a broad overview of recent progress in the use of triggers that can be used to achieve modulation of drug release rates from implantable biomaterials. In particular, these can be classified as being responsive to one or more of the following stimuli: a 15 chemical species, light, heat, magnetism, ultrasound and mechanical force. What the reader will gain: An overview of the potential for triggered drug delivery to give methods for tailoring the dose, location and time of release of a wide range of drugs where traditional dosing methods are not suitable. Particular emphasis is given to recently reported systems, and important 20 historical reports are included. Take home message: The use of externally or internally applied triggers of drug delivery to biomaterials has significant potential for improved delivery modalities and infection resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanochemical transduction enables an extraordinary range of physiological processes such as the sense of touch, hearing, balance, muscle contraction, and the growth and remodelling of tissue and
bone1–6. Although biology is replete with materials systems that actively and functionally respond to mechanical stimuli, the default mechanochemical reaction of bulk polymers to large external stress is the unselective scission of covalent bonds, resulting in damage or failure7. An alternative to this degradation process is the rational molecular design of synthetic materials such that mechanical stress
favourably altersmaterial properties. A few mechanosensitive polymers with this property have been developed8–14; but their active response is mediated through non-covalent processes, which may
limit the extent to which properties can be modified and the longterm stability in structural materials. Previously, we have shown with dissolved polymer strands incorporating mechanically sensitive chemical groups—so-called mechanophores—that the directional nature of mechanical forces can selectively break and re-form covalent bonds15,16. We now demonstrate that such forceinduced covalent-bond activation can also be realized with mechanophore-linked elastomeric and glassy polymers, by using a mechanophore that changes colour as it undergoes a reversible electrocyclic ring-opening reaction under tensile stress and thus allows us to directly and locally visualize the mechanochemical reaction. We find that pronounced changes in colour and fluorescence emerge with the accumulation of plastic deformation, indicating that in these polymeric materials the transduction of mechanical force into the ring-opening reaction is an activated process. We anticipate that force activation of covalent bonds can serve as a general strategy for the development of new mechanophore building blocks that impart polymeric materials with desirable functionalities ranging from damage sensing to fully regenerative self-healing.