4 resultados para river monitoring

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quantifying nutrient and sediment loads in catchments is dif?cult owing to diffuse controls related to storm hydrology. Coarse sampling and interpolation methods are prone to very high uncertainties due to under-representation of high discharge, short duration events. Additionally, important low-?ow processes such as diurnal signals linked to point source impacts are missed. Here we demonstrate a solution based on a time-integrated approach to sampling with a standard 24 bottle autosampler con?gured to take a sample every 7 h over a week according to a Plynlimon design. This is evaluated with a number of other sampling strategies using a two-year dataset of sub-hourly discharge and phosphorus concentration data. The 24/7 solution is shown to be among the least uncertain in estimating load (inter-quartile range: 96% to 110% of actual load in year 1 and 97% to 104% in year 2) due to the increased frequency raising the probability of sampling storm events and point source signals. The 24/7 solution would appear to be most parsimonious in terms of data coverage and certainty, process signal representation, potential laboratory commitment, technology requirements and the ability to be widely deployed in complex catchments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is growing interest in the application of electrode-based measurements for monitoring microbial processes in the Earth using biogeophysical methods. In this study, reactive electrode measurements were combined to electrical geophysical measurements during microbial sulfate reduction occurring in a column of silica beads saturated with natural river water. Electrodic potential (EP), self potential (SP) and complex conductivity signals were recorded using a dual electrode design (Ag/AgCl metal as sensing/EP electrode, Ag/AgCl metal in KCl gel as reference/SP electrode). Open-circuit potentials, representing the tendency for electrochemical reactions to occur on the electrode surfaces, were recorded between sensing/EP electrode and reference/SP electrode and showed significant spatiotemporal variability associated with microbial activity. The dual electrode design isolates the microbial driven sulfide reactions to the sensing electrode and permits removal of any SP signal from the EP measurement. Based on the known sensitivity of a Ag electrode to dissolved sulfide, we interpret EP signals exceeding 550 mV recorded in this experiment in terms of bisulfide (HS-) concentration near multiple sensing electrodes. Complex conductivity measurements capture an imaginary conductivity (s?) signal interpreted as the response of microbial growth and biomass formation in the column. Our results suggest that the implementation of multipurpose electrodes, combining reactive measurements with electrical geophysical measurements, could improve efforts to monitor microbial processes in the Earth using electrodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PCB congener concentrations in the water column of a highly industrialized river catchment, the Aire/Calder, in N.E. England were determined weekly on a routine basis, and 2 hourly through selected high flow (flood) events. Bed, suspended and floodplain sediment PCB congener concentrations were also determined along transects of the rivers investigated. Weekly monitoring revealed that the sum of 11 quantified (Sigma11) PCBs rose in concentration by two orders of magnitude during late summer compared to their winter minimum values. This rise was concurrent with sustained periods of low flow. SigmaPCB concentrations were rapidly diluted during high flow (flood) events. Suspended sediment was, on average, 13 times more contaminated with PCBs than bed sediment, with means of 4.0 and 53.8 ng/g, respectively, while floodplain samples had an intermediate concentration of 29.8 ng/g. Principle components analysis (PCA) of congener profiles showed that all three sediment types were similar, but that congener profiles differed considerably between sediment and whole-water samples. There was no change in the percentage contribution of individual PCB congeners apparent from weekly whole-water monitoring. However, the congener pattern in whole-waters changed systematically during high flow events. PCA showed that whole-water samples collected during high flow events had progressively more sediment characteristics, and then returned to whole-water characteristics on cessation of the event. The PCA evidence, dilution of PCB concentrations during events, and suspended sediments more contaminated than bed sediments, indicate that the major sources of PCBs in this catchment are current inputs from sewage treatment works, rather than remobilization of bed sediments.