190 resultados para return loss

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method for the selection of the appropriate choice of surface-mounted loading resistor required for a thin radar absorber based on a high-impedance surface (HIS) principle is demonstrated. The absorber consists of a HIS, (artificial magnetic ground plane), thickness 0.03 lambda(0) surface-loaded resistive-elements interconnecting a textured surface of square patches. The properties of absorber are characterized under normal incident using a parallel plate waveguide measurement technique over the operating frequency range of 2.6-3.95 GHz. We show that for this arrangement return loss and bandwidth are insensitive to +/- 2% tolerance variations in surface resistor values about the value predicted using the method elaborated in this letter, and that better than -28 dB at 3.125 GHz reflection loss can be obtained with an effective working bandwidth of up to 11% at -10 dB reflection loss. (C) 2009 Wiley Periodicals, Inc. Microwave Opt Technol Lett 51: 1733-1775, 2009; Published online in Wiley Interscience (www.interscience.wiley.com). DOI 10.1002/mop.24454

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple design for a low-profile high-gain planar antenna has been presented in the letter. The antenna has the realized gain between 9 and 11 dBi and the return loss better than 10 dB over the 5.6-6.3-GHz frequency band, i.e. 11% bandwidth. A numerical study highlighting effects of key geometrical parameters on the gain and return loss of the antenna has been performed. It has been shown as well that the presented antenna occupies area 20% smaller than a conventional microstrip patch antenna array with a similar gain.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a serpentine flexure spring design and fabrication process development for radio frequency microelectromechanical (RF MEMS) capacitive switches with coplanar waveguide (CPW) lines. Sputtered tungsten is employed as the CPW line conductor instead of Au, a non-Si compatible material. The bridge membrane is fabricated from Al. The materials and fabrication process can be integrated with CMOS and SOI technology to reduce cost. Results show the MEMS switch has excellent performance with insertion loss 0.3dB, return loss -27dB at 30GHz and high isolation -30dB at 40GHz. The process developed promises to simplify the design and fabrication of RF MEMS on silicon.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports a new method for reducing theRadar Cross-Section (RCS) of a metal backed dipole antenna. Numerical simulations are used to show that when the Perfect Electrical Conductor (PEC) is replaced by a carefully designedFrequency Selective Surface (FSS), the electromagnetic performanceof the antenna is similar in band, but the RCS of the structure is significantly lower out of band. The design of the FSSand the return loss, radiation patterns and RCS are presentedfor an antenna which operates at a center frequency of 4 GHzand the results are compared with a conventional metal backed arrangement

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A compact implantable printed meandered folded dipole antenna with a volume of 101.8 mm3 and robust performance is presented for operation in the 2.4 GHz medical ISM bands. The implant antenna is shown to maintain its return loss performance in the 2360???2400 MHz, 2400???2483.5 MHz and 2483.5???2500 MHz frequency bands, simulated in eleven different body tissue types with a broad range of electrical properties. Bandwidth and resonant frequency changes are reported for the same antenna implanted in high water content tissues such as muscle and skin as well as low water content tissues such as subcutaneous fat and bone. The antenna was also shown to maintain its return loss performance as it was moved towards a tissue boundary within a simulated phantom testbed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is shown that the direction-of-arrival (DoA) information carried by an incident electromagnetic (EM) wave can be encoded into the evanescent near field of an electrically small resonance antenna array with a spatial rate higher than that of the incident field oscillation rate in free space. Phase conjugation of the received signal leads to the retrodirection of the near field in the antenna array environment, which in turn generates a retrodirected far-field beam toward the original DoA. This EM phenomenon enables electrically small retrodirective antenna arrays with superdirective, angular super-resolution, auto-pointing properties for an arbitrary DoA. A theoretical explanation of the phenomenon based on first principal observations is given and full-wave simulations demonstrate a realizability route for the proposed retrodirective terminal that is comprised of resonance dipole antenna elements. Specifically, it is shown that a three-element disk-loaded retrodirective dipole array with 0.15\lambda spacings can achieve a 3.4-dBi maximal gain, 3-dBi front-to-back ratio, and 13% return loss fractional bandwidth (at the 10-dB level). Then, it is demonstrated that the radiation gain of a three-element array can be improved to approximately 6 dBi at the expense of the return loss fractional bandwidth reduction (2%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Recent National Institute of Clinical Excellence guidance suggests primary surgery should be offered to patients presenting with glaucoma with severe visual field loss. We undertook a survey of UK consultant ophthalmologists to determine if this represents current practice and explore attitudes towards managing patients with advanced glaucoma at presentation.

DESIGN: Questionnaire evaluation study.

PARTICIPANTS: All consultant ophthalmologists currently practicing in the UK.

METHODS: A single-page questionnaire was posted to all consultants (n = 910) currently practicing in the UK along with a pre-paid return envelope. A second questionnaire was sent to non-responders (n = 459).

MAIN OUTCOME MEASURES: Questionnaire responses.

RESULTS: 626 responses were received representing 68.8% of the population surveyed. 152 (24%) volunteered a specialist interest in glaucoma. Consensus opinion for both glaucoma specialists (64.9%) and non-glaucoma specialists (62.4%) was to start with primary medical therapy, most commonly citing surgical risk as the primary reason (23% and 22%, respectively) for this approach. Most felt the highest intraocular pressure measurement during follow up (measured in clinic) was the most important variable for prevention of further visual loss (60% of glaucoma specialists and 55% of non-glaucoma specialists). Eighty-three per cent of all responders suggested they would change their practice if evidence supporting primary surgery as a safe and more effective approach existed.

CONCLUSIONS: Recent National Institute of Clinical Excellence guidance does not reflect the current management approach of UK ophthalmologists. The primary concern was related to potential complications of surgery although most practitioners would be willing to change their practice if evidence existed supporting primary surgery in patients presenting with advanced glaucoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the design, implementation, and characterization of a new type of passive power splitting and combining structure for use in a differential four-way power-combining amplifier operating at E-band. In order to achieve lowest insertion loss, input and output coils inductances are resonated with shunt capacitances. Simple C-L-C and L-C networks are proposed in order to compensate inductive loading due to routing line that would otherwise introduce mismatch and increase loss. Across 78-86 GHz band, measured insertion loss is about 7 dB. Measured return losses are >10 dB from 73 GHz to 94 GHz at the input port and >9 dB from 60 GHz to 94 GHz at the output port. When integrated with driver and power amplifier cells, the simulated complete circuit exhibits 18.2 dB gain and 20.3 dBm saturated output power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies suggest that activation of phosphoinositide 3-kinase-Akt may protect against neuronal cell death in Alzheimer's disease (AD). Here, however, we provide evidence of increased Akt activation, and hyperphosphorylation of critical Akt substrates in AD brain, which link to AD pathogenesis, suggesting that treatments aiming to activate the pathway in AD need to be considered carefully. A different distribution of Akt and phospho-Akt was detected in AD temporal cortex neurons compared with control neurons, with increased levels of active phosphorylated-Akt in particulate fractions, and significant decreases in Akt levels in AD cytosolic fractions, causing increased activation of Akt (phosphorylated-Akt/total Akt ratio) in AD. In concordance, significant increases in the levels of phosphorylation of total Akt substrates, including: GSK3ßSer9, tauSer214, mTORSer2448, and decreased levels of the Akt target, p27kip1, were found in AD temporal cortex compared with controls. A significant loss and altered distribution of the major negative regulator of Akt, PTEN (phosphatase and tensin homologue deleted on chromosome 10), was also detected in AD neurons. Loss of phosphorylated-Akt and PTEN-containing neurons were found in hippocampal CA1 at end stages of AD. Taken together, these results support a potential role for aberrant control of Akt and PTEN signalling in AD.