162 resultados para reduced equation

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation sDEd approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES:

Renal disease is increasingly regarded as an independent risk factor for vascular disease which in itself is believed to influence risk of AD. Alterations in amyloid homeostasis via reduced renal clearance of peripheral beta-amyloid (A|*beta*|) may represent another potential role for variation in renal function leading to increased risk of AD. We sought to examine estimates of glomerular filtration rate in AD and control groups.
METHODS:

AD patients were randomly recruited from the Memory Clinic of the Belfast City Hospital (n = 83). Genomic DNA was extracted from peripheral leucocytes and was genotyped for Apolipoprotein E using standard methods. Using creatinine values, age and gender, estimated Glomerular Filtration Rates (eGFR) were calculated using the isotope dilution mass spectrometry (IDMS)-traceable Modification of Diet in Renal Disease (MDRD) Study equation (using the United Kingdom National External Quality Assessment Scheme (UKNEQAS) correction factor). IDMS eGFR values were then compared between AD and control groups.

RESULTS:

Significant baseline differences in age, diastolic blood pressure, education level attained and APOE |*epsilon*|4 carriage were noted between cases and controls. The AD group had a significantly lower eGFR versus controls (69 vs 77 ml/min) which persisted after adjustment for possible confounders (p = 0.045).

CONCLUSIONS:

This case-control analysis suggests that using a relatively accurate estimate of renal function, patients with AD have greater renal impairment than cognitively normal controls. This may reflect impaired renal clearance of peripheral A|*beta*| or be a marker of shared vascular processes altering cerebral and renal functioning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: CKD as defined by KDIGO/KDOQI has been shown to affect ~ 8.5% of the UK population. The prevalence of CKD in the UK is similar to that in the USA, yet incident dialysis rates are dramatically different. This retrospective cohort study investigates the association between reduced kidney function and mortality in a large UK population. METHODS: All serum creatinine results covering Northern Ireland's 1.7 million population were collected between 1 January 2001 and 31 December 2002. Estimated glomerular filtration rates (eGFR) were calculated for all serum creatinine measurements using four-variable MDRD equation (IDMS aligned). Patients were followed up for both all-cause and cardiovascular mortality data until the end of December 2006. Patients on renal replacement therapy were excluded. Subgroup analysis in the 75 345 subjects enrolled within a parallel primary care study permitted additional survival analysis with adjustment for traditional cardiovascular risk factors. RESULTS: A total of 1 967 827 serum creatinine results from 533 798 patients were collected. During the period of follow-up, 59 980 deaths occurred. In multivariate survival analysis, using eGFR as a time-varying covariate, a graded association between CKD (defined by eGFR) and all-cause mortality was identified. Compared with participants with an eGFR of > 60 mL/min/1.73 m(2), the adjusted hazard ratios (and 95% confidence intervals) for participants with an eGFR of 45-59 mL/min/1.73 m(2) was 1.02 (0.99-1.04), an eGFR of 30-44 mL/min/1.73 m(2) was 1.44 (1.40-1.47), an eGFR of 15-29 mL/min/1.73 m(2) was 2.12 (2.05-2.20) and an eGFR of

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation (DE) approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Childhood asthma is characterized by inflammation of the airways. Structural changes of the airway wall may also be seen in some children early in the course of the disease. Matrix metalloproteinases (MMPs) are key mediators in the metabolism of the extracellular matrix (ECM). Objective To investigate the balance of MMP-8, MMP-9 and tissue inhibitor of metalloproteinases (TIMP)-1 in the airways of children with asthma. Methods One hundred and twenty-four children undergoing elective surgical procedures also underwent non-bronchoscopic bronchoalveolar lavage (BAL). MMP-8, MMP-9 and TIMP-1 were measured by ELISA. Results There was a significant reduction in MMP-9 in atopic asthmatic children (n=31) compared with normal children (n=30) [median difference: 0.57 ng/mL (95% confidence interval: 0.18–1.1 ng/mL)]. The ratio of MMP-9 to TIMP-1 was also reduced in asthmatic children. Levels of all three proteins were significantly correlated to each other and to the relative proportions of particular inflammatory cells in BAL fluid (BALF). Both MMP-8 and MMP-9 were moderately strongly correlated to the percentage neutrophil count (r=0.40 and 0.47, respectively, P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characterization of thermocouple sensors for temperature measurement in varying-flow environments is a challenging problem. Recently, the authors introduced novel difference-equation-based algorithms that allow in situ characterization of temperature measurement probes consisting of two-thermocouple sensors with differing time constants. In particular, a linear least squares (LS) lambda formulation of the characterization problem, which yields unbiased estimates when identified using generalized total LS, was introduced. These algorithms assume that time constants do not change during operation and are, therefore, appropriate for temperature measurement in homogenous constant-velocity liquid or gas flows. This paper develops an alternative ß-formulation of the characterization problem that has the major advantage of allowing exploitation of a priori knowledge of the ratio of the sensor time constants, thereby facilitating the implementation of computationally efficient algorithms that are less sensitive to measurement noise. A number of variants of the ß-formulation are developed, and appropriate unbiased estimators are identified. Monte Carlo simulation results are used to support the analysis.