18 resultados para photolysis, ozone tendency

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical generation of ozone by Ni/Sb-SnO2 anodes immersed in 0.5M H2SO4 was assessed in both flow and recycle systems using the same electrochemical cell. The anodes were found to exhibit current efficiencies of up to 50% for ozone generation under flow conditions at room temperature, with an optimum mole ratio in the precursor solutions of ca. 500:8:3 Sn:Sb:Ni and optimum cell voltage of 2.7V. A comparison of the data obtained under flow and recycle conditions suggests that the presence of ozone in the anolyte inhibits its formation. The minimum electrical energy cost achieved, of 18 kWh kg1 compares favorably with estimated costs for Cold Corona Discharge generally reported in the literature, especially when the very significant advantages of electrochemical ozone generation are taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silver colloids have been prepared by reducing AgNO3 in aqueous solution and embeded in alumina following a sol-gel procedure in the presence of Pluronic 84 ((EO)(19)(PO)(39)(EO)(19)), as surfactant. Plasma-catalytic experiments aimed at the mineralization of toluene showed that the selectivity to CO2 was significantly increased in the presence of Ag catalysts compared with results obtained using the plasma alone. In-situ studies of the ozone interaction with catalysts provide an insight into the nature of the active sites of supported silver colloids for mineralization reactions. It is noticeable that when ozone is chemisorbed on embedded Ag colloidal catalysts no change in the silver oxidation state or size is found. The population of the chemisorbed species is higher at lower temperatures, where the non-selective decomposition of ozone is smaller. The catalysts exhibit high stability, preserving the structural and textural properties after the catalytic tests, that is indeed very important in the presence of ozone. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High levels of ozone (typically 850 ppm) are readily decomposed by semiconductor photocatalysis, using a thin film of the semiconductor titanium dioxide (Degussa P25 TiO2) cast on a glass tube, and UVA light, i.e. light of energy greater than that of the bandgap of the semiconductor (ultra-bandgap light); in the absence of this light the thermal decomposition of ozone is relatively slow. The semiconductor films show no evidence of chemical or photochemical wear with repeated use. At high levels of ozone, i.e. 100 ppm less than or equal to [O-3] less than or equal to 1400 ppm, the initial rate of ozone decomposition by semiconductor photocatalysis is independent of [O-3], whereas, at lower ozone concentrations, i.e. 5 ppm less than or equal to [O-3] less than or equal to 100 ppm, the initial rate of ozone photodestruction decreases in a smooth, but non-linear, manner with decreasing [O-3]. The kinetics of ozone photodecomposition fit a Langmuir-Hinshelwood type kinetic equation and the possible mechanistic implications of these results are briefly discussed. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD