21 resultados para patient monitoring

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radio-based signalling devices will play an important role in future generations of remote patient monitoring equipment, both at home and in hospital. Ultimately, it will be possible to sample vital signs frompatients, whatever their location and without them necessarily being aware that a measurement is being taken. This paper reviews currentmethods for the transmission by radio of physiological parameters over ranges of 0.3, 3 and 30 m, and describes the radiofrequency hardware required and the carrier frequencies commonly used. Future developments, including full duplex systems and the use of more advanced modulation schemes, are described. The paper concludeswith a case studyof a humantemperature telemeter built to indicateovulation. Clinical results clearly show the advantage to be had in adopting radio biotelemetry in this instance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The emerging field of microneedle-based minimally invasive patient monitoring and diagnosis is reviewed. Microneedle arrays consist of rows of micron-scale projections attached to a solid support. They have been widely investigated for transdermal drug and vaccine delivery applications since the late 1990s. However, researchers and clinicians have recently realized the great potential of microneedles for extraction of skin interstitial fluid and, less commonly, blood, for enhanced monitoring of patient health.

Methods: We reviewed the journal and patent literature, and summarized the findings and provided technical insights and critical analysis.

Results: We describe the basic concepts in detail and extensively review the work performed to date.

Conclusions: It is our view that microneedles will have an important role to play in clinical management of patients and will ultimately improve therapeutic outcomes for people worldwide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To explore children's views on microneedle use for this population, particularly as an alternative approach to blood sampling, in monitoring applications, and so, examine the acceptability of this approach to children.

Methods: Focus groups were conducted with children (aged 10-14 years) in a range of schools across Northern Ireland. Convenience sampling was employed, i.e. children involved in a university-directed community-outreach project (Pharmacists in Schools) were recruited.

Key findings: A total of 86 children participated in 13 focus groups across seven schools in Northern Ireland. A widespread disapproval for blood sampling was evident, with pain, blood and traditional needle visualisation particularly unpopular aspects. In general, microneedles had greater visual acceptability and caused less fear. A patch-based design enabled minimal patient awareness of the monitoring procedure, with personalised designs, e.g. cartoon themes, favoured. Children's concerns included possible allergy and potential inaccuracies with this novel approach; however, many had confidence in the judgement of healthcare professionals if deeming this technique appropriate. They considered paediatric patient education critical for acceptance of this new approach and called for an alternative name, without any reference to 'needles'.

Conclusions: The findings presented here support the development of blood-free, minimally invasive techniques and provide an initial indication of microneedle acceptability in children, particularly for monitoring purposes. A proactive response to these unique insights should enable microneedle array design to better meet the needs of this end-user group. Further work in this area is recommended to ascertain the perspectives of a purposive sample of children with chronic conditions who require regular monitoring. © 2013 Royal Pharmaceutical Society.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Research based upon microneedle (MN) arrays has intensified recently. While the initial focus was on biomolecules, the field has expanded to include delivery of conventional small-molecule drugs whose water solubility currently precludes transdermal administration. Much success has been achieved, with peptides, proteins, vaccines, antibodies and even particulates delivered by MN in therapeutic/prophylactic doses. Recent innovations have focused on enhanced formulation design, scalable manufacture and extension of exploitation to minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Only two MN-based drug/vaccine delivery products are currently marketed, partially due to limitations with older MN designs based upon silicon and metal. Even the more promising polymeric MN have raised a number of regulatory and manufacturability queries that the field must address. MN arrays have tremendous potential to yield real benefits for patients and industry and, through diligence, innovation and collaboration, this will begin to be realised over the next 3-5 years.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We describe, for the first time the use of hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) (11.1% w/w) and poly(ethyleneglycol) 10,000 daltons (5.6% w/w) and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min) analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL) and highest (35 μg/mL) Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration extracted from MN was 4.29 nmol/L, detected after 3 hours skin insertion in human volunteers. Whilst not directly correlated, concentrations extracted from MN were clearly indicative of trends in blood in both rats and human volunteers. This work strongly illustrates the potential of hydrogel-forming MN in minimally-invasive patient monitoring and diagnosis. Further studies are now ongoing to reduce clinical insertion times and develop mathematical algorithms enabling determination of blood levels directly from MN measurements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transdermal drug delivery offers a number of advantages for the patient, due not only its non-invasive and convenient nature, but also factors such as avoidance of first pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedle arrays can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below. Microneedles have been extensively investigated in recent decades for drug and vaccine delivery as well as minimally invasive patient monitoring/diagnosis. This review focuses on a range of critically important aspects of microneedle technology, namely their material composition, manufacturing techniques, methods of evaluation and commercial translation to the clinic for patient benefit and economic return. Microneedle research and development is finally now at the stage where commercialisation is a realistic possibility. However, progress is still required in the areas of scaled-up manufacture and regulatory approval.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microneedles (MNs) are minimally invasive devices consisting of numerous micron-sized projections amassed on a baseplate, designed to enhance transdermal drug delivery. When applied to the skin, the needles puncture the outermost layer, the stratum corneum, forming aqueous conduits through which drugs can diffuse to the dermal microcirculation. With an average length of 50-900 μm, MNs are short enough to avoid stimulation of dermal nerves and do not induce bleeding, yet gain access to the skin's rich microcirculation for drug delivery. MNs have been extensively investigated for drug and vaccine delivery, demonstrating their efficacy at increasing the number of compounds amenable to delivery through the skin. This chapter discusses the materials and fabrication methods involved in MN production, alongside the different types of MN arrays and their delivery capabilities. The field has expanded to consider novel applications of MNs including minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Patient usage and effects on the skin are also considered in terms of safety, efficacy and acceptability. The next steps in MN development are to focus on the scale-up of manufacturing processes, a challenge considering the number of small-scale methods detailed in the literature. Regulatory guidance is awaited to direct this, alongside provision of clearer patient instruction for safe and effective use of MN devices. MNs have tremendous potential to yield real benefits for patients and industry and with continued research in the key areas highlighted, this will begin to be realised over the next number of years.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissolved CO2 measurements are usually made using a Severinghaus electrode, which is bulky and can suffer from electrical interference. In contrast, optical sensors for gaseous CO2, whilst not suffering these problems, are mainly used for making gaseous (not dissolved) CO2 measurements, due to dye leaching and protonation, especially at high ionic strengths (>0.01 M) and acidity (<pH 4). This is usually prevented by coating the sensor with a gas-permeable, but ion-impermeable, membrane (GPM). Herein, we introduce a highly sensitive, colourimetric-based, plastic film sensor for the measurement of both gaseous and dissolved CO2, in which a pH-sensitive dye, thymol blue (TB) is coated onto particles of hydrophilic silica to create a CO2-sensitive, TB-based pigment, which is then extruded into low density polyethylene (LDPE) to create a GPM-free, i.e. naked, TB plastic sensor film for gaseous and dissolved CO2 measurements. When used for making dissolved CO2 measurements, the hydrophobic nature of the LDPE renders the film: (i) indifferent to ionic strength, (ii) highly resistant to acid attack and (iii) stable when stored under ambient (dark) conditions for >8 months, with no loss of colour or function. Here, the performance of the TB plastic film is primarily assessed as a dissolved CO2 sensor in highly saline (3.5 wt%) water. The TB film is blue in the absence of CO2 and yellow in its presence, exhibiting 50% transition in its colour at ca. 0.18% CO2. This new type of CO2 sensor has great potential in the monitoring of CO2 levels in the hydrosphere, as well as elsewhere, e.g. food packaging and possibly patient monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. This paper is a report of a study to describe how treatment fidelity is being enhanced and monitored, using a model from the National Institutes of Health Behavior Change Consortium. Background. The objective of treatment fidelity is to minimize errors in interpreting research trial outcomes, and to ascribe those outcomes directly to the intervention at hand. Treatment fidelity procedures are included in trials of complex interventions to account for inferences made from study outcomes. Monitoring treatment fidelity can help improve study design, maximize reliability of results, increase statistical power, determine whether theory-based interventions are responsible for observed changes, and inform the research dissemination process. Methods. Treatment fidelity recommendations from the Behavior Change Consortium were applied to the SPHERE study (Secondary Prevention of Heart DiseasE in GeneRal PracticE), a randomized controlled trial of a complex intervention. Procedures to enhance and monitor intervention implementation included standardizing training sessions, observing intervention consultations, structuring patient recall systems, and using written practice and patient care plans. The research nurse plays an important role in monitoring intervention implementation. Findings. Several methods of applying treatment fidelity procedures to monitoring interventions are possible. The procedure used may be determined by availability of appropriate personnel, fiscal constraints, or time limits. Complex interventions are not straightforward and necessitate a monitoring process at trial stage. Conclusion. The Behavior Change Consortium’s model of treatment fidelity is useful for structuring a system to monitor the implementation of a complex intervention, and helps to increase the reliability and validity of evaluation findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Juvenile idiopathic arthritis (JIA) comprises a poorly understood group of chronic, childhood onset, autoimmune diseases with variable clinical outcomes. We investigated whether profiling of the synovial fluid (SF) proteome by a fluorescent dye based, two-dimensional gel (DIGE) approach could distinguish patients in whom inflammation extends to affect a large number of joints, early in the disease process. SF samples from 22 JIA patients were analyzed: 10 with oligoarticular arthritis, 5 extended oligoarticular and 7 polyarticular disease. SF samples were labeled with Cy dyes and separated by two-dimensional electrophoresis. Multivariate analyses were used to isolate a panel of proteins which distinguish patient subgroups. Proteins were identified using MALDI-TOF mass spectrometry with expression further verified by Western immunoblotting and immunohistochemistry. Hierarchical clustering based on the expression levels of a set of 40 proteins segregated the extended oligoarticular from the oligoarticular patients (p <0.05). Expression patterns of the isolated protein panel have also been observed over time, as disease spreads to multiple joints. The data indicates that synovial fluid proteome profiles could be used to stratify patients based on risk of disease extension. These protein profiles may also assist in monitoring therapeutic responses over time and help predict joint damage. © 2009 American Chemical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.