48 resultados para paire de vortex-antivortex
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
We study the establishment of vortex entanglement in remote Bose-Einstein condensates (BECs). We consider a two-mode photonic resource entangled in its orbital angular momentum (OAM) degree of freedom and, by exploiting the process of light-to-BEC OAM transfer, demonstrate that such entanglement can be efficiently passed to the matterlike systems. Our proposal thus represents a building block for novel dissipation-free and long-memory communication channels based on OAM. We discuss issues of practical realizability, stressing the feasibility of our scheme, and present an operative technique for the indirect inference of the set vortex entanglement.
Resumo:
A method for measuring the phase of oscillations from noisy time series is proposed. To obtain the phase, the signal is filtered in such a way that the filter output has minimal relative variation in the amplitude over all filters with complex-valued impulse response. The argument of the filter output yields the phase. Implementation of the algorithm and interpretation of the result are discussed. We argue that the phase obtained by the proposed method has a low susceptibility to measurement noise and a low rate of artificial phase slips. The method is applied for the detection and classification of mode locking in vortex flow meters. A measure for the strength of mode locking is proposed.
Resumo:
Effects of inappropriate installation can bias the measurements of flowmeters. For vortex flowmeters, a method is proposed to detect inappropriate installation of the flowmeter from the oscillatory signal of the vortex sensor. The method is based on assuming the process of vortex generation to be a generic, noisy, nonlinear oscillation, describable by a noisy Stuart-Landau equation, with a corresponding sensor signal that also contains higher harmonic excitations. By making use of the scaling properties of the Navier-Stokes Equation, the method was designed to be robust with respect to uncertainties in the fluid properties. The diagnostic functionality is demonstrated on measurement data. In the experiments, installation effects that lead to more than 0.5% error in the output of the flowmeter could clearly be detected. (C) 2003 Elsevier Ltd. All rights reserved.