110 resultados para out-of-hospital cardiac arrest

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To determine whether 80-lead body surface potential mapping (BSPM) improves detection of acute coronary artery occlusion in patients presenting with out-of-hospital cardiac arrest (OHCA) due to ventricular fibrillation (VF) and who survived to reach hospital. Methods and results: Of 645 consecutive patients with OHCA who were attended by the mobile coronary care unit, VF was the initial rhythm in 168 patients. Eighty patients survived initial resuscitation, 59 of these having had BSPM and 12-lead ECG post-return of spontaneous circulation (ROSC) and in 35 patients (age 69±13 yrs; 60% male) coronary angiography performed within 24. h post-ROSC. Of these, 26 (74%) patients had an acutely occluded coronary artery (TIMI flow grade [TFG] 0/1) at angiography. Twelve-lead ECG criteria showed ST-segment elevation (STE) myocardial infarction (STEMI) using Minnesota 9-2 criteria - sensitivity 19%, specificity 100%; ST-segment depression (STD) =0.05. mV in =2 contiguous leads - sensitivity 23%, specificity 89%; and, combination of STEMI or STD criteria - sensitivity 46%, specificity 100%. BSPM STE occurred in 23 (66%) patients. For the diagnosis of TFG 0/1 in a main coronary artery, BSPM STE had sensitivity 88% and specificity 100% (c-statistic 0.94), with STE occurring most commonly in either the posterior, right ventricular or high right anterior territories. Conclusion: Among OHCA patients presenting with VF and who survived resuscitation to reach hospital, post-resuscitation BSPM STE identifies acute coronary occlusion with sensitivity 88% and specificity 100% (c-statistic 0.94). © 2012 Elsevier Ireland Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the epidemiology of out of hospital sudden cardiac death (OHSCD) in Belfast from 1 August 2003 to 31 July 2004.

Design: Prospective examination of out of hospital cardiac arrests by using the Utstein style and necropsy reports. World Health Organization criteria were applied to determine the number of sudden cardiac deaths.

Results: Of 300 OHSCDs, 197 (66%) in men, mean age (SD) 68 (14) years, 234 (78%) occurred at home. The emergency medical services (EMS) attended 279 (93%). Rhythm on EMS arrival was ventricular fibrillation (VF) in 75 (27%). The call to response interval (CRI) was mean (SD) 8 (3) minutes. Among patients attended by the EMS, 9.7% were resuscitated and 7.2% survived to leave hospital alive. The CRI for survivors was mean (SD) 5 (2) minutes and for non-survivors, 8 (3) minutes (p < 0.001). Ninety one (30%) OHSCDs were witnessed; of these 91 patients 48 (53%) had VF on EMS arrival. The survival rate for witnessed VF arrests was 20 of 48 (41.7%): all 20 survivors had VF as the presenting rhythm and CRI ? 7 minutes. The European age standardised incidence for OHSCD was 122/100 000 (95% confidence interval 111 to 133) for men and 41/100 000 (95% confidence interval 36 to 46) for women.

Conclusion: Despite a 37% reduction in heart attack mortality in Ireland over the past 20 years, the incidence of OHSCD in Belfast has not fallen. In this study, 78% of OHSCDs occurred at home.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Less than 1% of the general public know how to assess or manage someone who has collapsed. It has been estimated that if 15–20% of the population were capable of performing cardiopulmonary resuscitation (CPR), mortality of out of hospital cardiac arrest could be decreased significantly. Training basic life support (BLS) skills to school children would be the most cost effective way of achieving this goal and ensuring that a large proportion of the population acquire basic life saving skills. Aims To assess retention of knowledge of basic life support 6 months after a single course of instruction in cardiopulmonary resuscitation designed specifically for school children. Setting School pupils in a rural location in one region of the United Kingdom. Methods A course of instruction in cardiopulmonary resuscitation – the ‘ABC for life’ programme – specifically designed to teach 10–12-year-old school children basic life support skills. The training session was given to school pupils in a rural location in Northern Ireland. A 22 point questionnaire was used to assess acquisition and retention of basic life support knowledge. Results Children instructed in cardiopulmonary resuscitation showed a highly significant increase in level of knowledge following the training session. While their level of knowledge decreased over a period of 6 months it remained significantly higher than that of a comparable group of children who had never been trained. Conclusion A training programme designed and taught as part of the school curriculum would have a significant impact on public health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?

DESIGN: Clinical study.

SETTING: University hospital.

PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.

INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.

MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).

CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An algorithm based only on the impedance cardiogram (ICG) recorded through two defibrillation pads, using the strongest frequency component and amplitude, incorporated into a defibrillator could determine circulatory arrest and reduce delays in starting cardiopulmonary resuscitation (CPR). Frequency analysis of the ICG signal is carried out by integer filters on a sample by sample basis. They are simpler, lighter and more versatile when compared to the FFT. This alternative approach, although less accurate, is preferred due to the limited processing capacity of devices that could compromise real time usability of the FFT. These two techniques were compared across a data set comprising 13 cases of cardiac arrest and 6 normal controls. The best filters were refined on this training set and an algorithm for the detection of cardiac arrest was trained on a wider data set. The algorithm was finally tested on a validation set. The ICG was recorded in 132 cardiac arrest patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with a sensitivity of 81.1% (77.6-84.3) and specificity of 97.1% (96.7-97.4) for the validation set (95% confidence intervals). Automated defibrillators with integrated ICG analysis have the potential to improve emergency care by lay persons enabling more rapid and appropriate initiation of CPR and when combined with ECG analysis they could improve on the detection of cardiac arrest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the results of an investigation, by postal questionnaire, of the views of 30 General Practitioners about a model of out of hospital care – the home from hospital (HFH) service, which mainly provides social care and rehabilitation for patients in their own home. The GPs, who all worked within one of the Health and Social Services Board areas in Northern Ireland during the time of the study (March-April 1998), indicated that the introduction of the HFH service, unlike other models of out of hospital care, did not increase their workload. Therefore, it is suggested that the HFH model of care should be given more attention in terms of research evaluation and service development.