7 resultados para optical pupil filter

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of a low loss quasi-optical beam splitter which is required to provide efficient diplexing of the bands 316.5-325.5 GHz and 349.5-358.5 GHz is presented. To minimise the filter insertion loss, the chosen architecture is a three-layer freestanding array of dipole slot elements. Floquet modal analysis and finite element method computer models are used to establish the geometry of the periodic structure and to predict its spectral response. Two different micromachining approaches have been employed to fabricate close packed arrays of 460 mm long elements in the screens that form the basic building block of the 30mm diameter multilayer frequency selective surface. Comparisons between simulated and measured transmission coefficients for the individual dichroic surfaces are used to determine the accuracy of the computer models and to confirm the suitability of the fabrication methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel acousto-optic spectrometer (IfU Diagnostic Systems GmbH) for 2-dimensional (2D) optical emission spectroscopy with high spectral resolution has been developed. The spectrometer is based on acousto-optic tuneable filter technology with fast random wavelength access. Measurements for characterisation of the imaging quality, the spatial resolution, and the spectral resolution are presented. The applicability for 2D-space and phase resolved optical emission spectroscopy (2D-PROES) is shown. 2D-PROES has been applied to an inductively coupled plasma with radio frequency excitation at 13.56 MHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel 3rd-order compact E-plane ridge waveguide filter is presented. Miniaturization is achieved upon introducing a configuration of parallel-coupled E-plane ridge waveguide resonators. Furthermore, the proposed filter allows for transmission zeros at finite frequencies. Fabrication simplicity and mass producibility of standard E-plane filters is maintained. The numerical and experimental results are presented to validate the proposed configuration. A miniaturisation factor of 2 and very sharp upper cutoff are achieved. 2005 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow maldistribution of the exhaust gas entering a Diesel Particulate Filter (DPF) can cause uneven soot distribution during loading and excessive temperature gradients during the regeneration phase. Minimising the magnitude of this maldistribution is therefore an important consideration in the design of the inlet pipe and diffuser, particularly in situations where packaging constraints dictate bends in the inlet pipe close to the filter, or a sharp diffuser angle. This paper describes the use of Particle Image Velocimetry (PIV) to validate a Computational Fluid Dynamic (CFD) model of the flow within the inlet diffuser of a DPF so that CFD can be used with confidence as a tool to minimise this flow maldistribution. PIV is used to study the flow of gas into a DPF over a range of steady state flow conditions. The distribution of flow approaching the front face of the substrate was of particular interest to this study. Optically clear diffusing cones were designed and placed between pipe and substrate to allow PIV analysis to take place. Stereoscopic PIV was used to eliminate any error produced by the optical aberrations caused by looking through the curved wall of the inlet cone. In parallel to the experiments, numerical analysis was carried out using a CFD program with an incorporated DPF model. Boundary conditions for the CFD simulations were taken from the experimental data, allowing an experimental validation of the numerical results. The CFD model incorporated a DPF model, the cement layers seen in segmented filters and the intumescent matting that is commonly used to pack the filter into a metal casing. The mesh contained approximately 580,000 cells and used the realizable ?-e turbulence model. The CFD simulation predicted both pressure drop across the DPF and the velocity field within the cone and at the DPF face with reasonable accuracy, providing confidence in the use the CFD in future work to design new, more efficient cones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Relevant to laser based electron/ion accelerations, a single shot second harmonic generation frequency resolved optical gating (FROG) system has been developed to characterize laser pulses (80 J, ∼600 fs) incident on and transmitted through nanofoil targets, employing relay imaging, spatial filter, and partially coated glass substrates to reduce spatial nonuniformity and B-integral. The device can be completely aligned without using a pulsed laser source. Variations of incident pulse shape were measured from durations of 613 fs (nearly symmetric shape) to 571 fs (asymmetric shape with pre- or postpulse). The FROG measurements are consistent with independent spectral and autocorrelation measurements. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. METHODS: Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. RESULTS: A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P < 0.001) and smaller than that in standard room illumination (P = 0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P < 0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P = 0.157). CONCLUSIONS: Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.