68 resultados para optic disc
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Image segmentation plays an important role in the analysis of retinal images as the extraction of the optic disk provides important cues for accurate diagnosis of various retinopathic diseases. In recent years, gradient vector flow (GVF) based algorithms have been used successfully to successfully segment a variety of medical imagery. However, due to the compromise of internal and external energy forces within the resulting partial differential equations, these methods can lead to less accurate segmentation results in certain cases. In this paper, we propose the use of a new mean shift-based GVF segmentation algorithm that drives the internal/external energies towards the correct direction. The proposed method incorporates a mean shift operation within the standard GVF cost function to arrive at a more accurate segmentation. Experimental results on a large dataset of retinal images demonstrate that the presented method optimally detects the border of the optic disc.
Resumo:
Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.
Resumo:
Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.
Resumo:
Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.
Resumo:
Objective: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). Design: Nonconsecutive observational case series. Participants and Intervention: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. Main Outcome Measures: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. Results: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5 ± 12 mmHg, and after surgery 11.8 ± 5.2 mmHg (mean follow-up, 26 ± 7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P <0.005). The age of the patient correlated highly with change in maximum cup depth (P <0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). Conclusion: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.
Resumo:
Purpose: The authors estimated the retinal nerve fiber layer height (RNFLH) measurements in patients with glaucoma compared with those in age-matched healthy subjects as obtained by the laser scanning tomography and assessed the relationship between RNFLH measurements and optic and visual field status. Methods: Parameters of optic nerve head topography and RNFLH were evaluated in 125 eyes of 21 healthy subjects and 104 patients with glaucoma using the Heidelberg Retina Tomograph ([HRT] Heidelberg Engineering GmbH, Heidelberg, Germany) for the entire disc area and for the superior 70°(50°temporal and 20°nasal to the vertical midline) and inferior 70°sectors of the optic disc. The mean deviation of the visual field, as determined by the Humphrey program 24-2 (Humphrey Instruments, Inc., San Leonardo, CA, U.S.A) was calculated in the entire field and in the superior and inferior Bjerrum area. Result: Retinal nerve fiber layer height parameters (mean RNFLH and RNFL cross-sectional area) were decreased significantly in patients with glaucoma compared with healthy individuals. Retinal nerve fiber layer height parameters was correlated strongly with rim volume, rim area, and cup/disc area ratio. Of the various topography measures, retinal nerve fiber layer (RNFL) parameters and cup/disc area ratio showed the strongest correlation with visual field mean deviation in patients with glaucoma. Conclusion: Retinal nerve fiber layer height measures were reduced substantially in patients with glaucoma compared with age-matched healthy subjects. Retinal nerve fiber layer height was correlated strongly with topographic optic disc parameters and visual field changes in patients with glaucoma.
Resumo:
Objective: Acquired pit-like changes of the optic nerve head (APON) are characteristic of glaucomatous damage and may be a sign of a localized susceptibility of the optic nerve. Thus, it is possible that biomechanical properties of the ocular tissues may play a pressure-independent role in the pathogenesis of glaucoma. Corneal hysteresis (CH) appears to provide information of the biomechanical properties of the ocular hull tissues. The purpose of this study was to compare CH of patients with primary open angle glaucoma (POAG) with and without APON. Methods: A prospective case control study was done. POAG patients with and without APON were measured using the Ocular Response Analyzer by masked investigators. Patients in both groups were matched for sex, age, corneal thickness, and type of glaucoma according to maximal IOP (NTG or POAG). Statistical analysis was done using ANOVA. Results: Corneal hysteresis of 16 glaucomatous eyes with APON and 32 controls (glaucoma without APON) was measured. The mean (±SD) CH in the APON group was 8.89 (±1.53) and 10.2 (±1.05) in the control group. The difference is statistically significant (p = 0.005). Conclusions: Corneal hysteresis in POAG patients with APON was significantly lower than in patients that did not have such structural changes of the optic disc. These findings may reflect pressure-independent mechanisms involved in the pathogenesis of such glaucomatous optic nerve changes. © Springer-Verlag 2007.
Resumo:
Objective: The authors evaluated the results of primary transpupillary thermotherapy for choroidal melanoma in 100 cases. Design: Prospective nonrandomized analysis of treatment method. Participants: One hundred patients with choroidal melanoma were studied. Main Outcome Measures: Tumor response, ocular side effects, and visual results. Results: Of 100 consecutive patients with choroidal melanoma treated with transpupillary thermotherapy, the mean tumor basal diameter was 7.1 mm and tumor thickness was 2.8 mm. The tumor margin touched the optic disc in 34 eyes (34%) and was beneath the fovea in 42 eyes (42%). Documented growth was present in 64 eyes (64%), and known clinical risks for growth were present in all of the remaining 36 eyes (36%), with an average of 4 of 5 statistical risk factors for growth per tumor. After a mean of three treatment sessions and 14 months of follow-up, the mean tumor thickness was reduced to 1.4 mm. Treatment was successful in 94 eyes (94%) and failed in 6 eyes (6%). Three patients with amelanotic tumors showed no initial response to thermotherapy, but subsequent intravenous indocyanine green administration during thermotherapy resulted in improved heat absorption and tumor regression to a flat scar. The six eyes classified as treatment failures included four eyes with tumors that showed partial or no response to thermotherapy, thus requiring plaque radiotherapy or enucleation, and two eyes with recurrence, subsequently controlled with additional thermotherapy. After treatment, the visual acuity was the same (within 1 line) or better than the pretreatment visual acuity in 58 eyes (58%) and worse in 42 eyes (42%). The main reasons for poorer vision included treatment through the foveola for subfoveal tumor (25 eyes), retinal traction (10 eyes), retinal vascular obstruction (5 eyes), optic disc edema (1 eye), and unrelated ocular ischemia (1 eye). Temporal location (versus nasal and superior, P = 0.02) and greater distance from the optic disc (P = 0.04) were risks for retinal traction. Conclusions: Transpupillary thermotherapy may be an effective treatment for small posterior choroidal melanoma, especially those near the optic disc and fovea. Despite satisfactory local tumor control, ocular side effects can result in decreased vision. Longer follow- up will be necessary to assess the impact of thermotherapy on ultimate local tumor control and metastatic disease.
Resumo:
Glaucoma is characterized by a typical appearance of the optic disc and peripheral visual field loss. However, diagnosis may be challenging even for an experienced clinician due to wide variability among normal and glaucomatous eyes. Standard automated perimetry is routinely used to establish the diagnosis of glaucoma. However, there is evidence that substantial retinal ganglion cell damage may occur in glaucoma before visual field defects are seen. The introduction of newer imaging devices such as confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography for measuring structural changes in the optic nerve head and retinal nerve fiber layer seems promising for early detection of glaucoma. New functional tests may also help in the diagnosis. However, there is no evidence that a single measurement is superior to the others and a combination of tests may be needed for detecting early damage in glaucoma. © 2010 Expert Reviews Ltd.
Resumo:
Purpose. To evaluate differences in optic disc and visual field damage between African-American and Caucasian Normal Tension Glaucoma (NTG) patients. Methods. We retrospectively selected 33 African-American patients with the diagnosis of NTG and age-matched them with 33 Caucasian patients with the same diagnosis. Three masked observers graded disc photographs and visual fields as being normal, globally damaged or focally damaged for both eyes of the subject. Chi-square test was used to evaluate statistically significant differences between groups. Results. The results of the visual fields showed that in the African-American group, 24% were graded normal, 30% showed global damage, and 46% showed focal damage. This data was compared with the Caucasian group which showed 41% normal graded eyes, 22% with global damage, and 37% with focal damage (p = 0.28). The results of the optic disc photos showed that in the African-American group, 25% were graded normal, 45% showed global damage, and 30% showed focal damage. This data was compared with the Caucasian group which showed 43% graded normal, 32% with global damage, and 25% with focal damage (p=0.16). Conclusions. In our study there was no difference in the frequency of globally damaged, focally damaged, and normal graded discs or visual fields between African-American and Caucasian NTG patients.
Resumo:
Abstract
AIMS/HYPOTHESIS:
Retinal vascular calibre changes may reflect early subclinical microvascular disease in diabetes. Because of the considerable homology between retinal and cerebral microcirculation, we examined whether retinal vascular calibre, as a proxy of cerebral microvascular disease, was associated with cognitive function in older people with type 2 diabetes.
METHODS:
A cross-sectional analysis of 954 people aged 60-75 years with type 2 diabetes from the population-based Edinburgh Type 2 Diabetes Study was performed. Participants underwent standard seven-field binocular digital retinal photography and a battery of seven cognitive function tests. The Mill Hill Vocabulary Scale was used to estimate pre-morbid cognitive ability. Retinal vascular calibre was measured from an image field with the optic disc in the centre using a validated computer-based program.
RESULTS:
After age and sex adjustment, larger retinal arteriolar and venular calibres were significantly associated with lower scores for the Wechsler Logical Memory test, with standardised regression coefficients -0.119 and -0.084, respectively (p?<?0.01), but not with other cognitive tests. There was a significant interaction between sex and retinal vascular calibre for logical memory. In male participants, the association of increased retinal arteriolar calibre with logical memory persisted (p?<?0.05) when further adjusted for vocabulary, venular calibre, depression, cardiovascular risk factors and macrovascular disease. In female participants, this association was weaker and not significant.
CONCLUSIONS/INTERPRETATION:
Retinal arteriolar dilatation was associated with poorer memory, independent of estimated prior cognitive ability in older men with type 2 diabetes. The sex interaction with stronger findings in men requires confirmation. Nevertheless, these data suggest that impaired cerebral arteriolar autoregulation in smooth muscle cells, leading to arteriolar dilatation, may be a possible pathogenic mechanism in verbal declarative memory decrements in people with diabetes.
Resumo:
In recent years, gradient vector flow (GVF) based algorithms have been successfully used to segment a variety of 2-D and 3-D imagery. However, due to the compromise of internal and external energy forces within the resulting partial differential equations, these methods may lead to biased segmentation results. In this paper, we propose MSGVF, a mean shift based GVF segmentation algorithm that can successfully locate the correct borders. MSGVF is developed so that when the contour reaches equilibrium, the various forces resulting from the different energy terms are balanced. In addition, the smoothness constraint of image pixels is kept so that over- or under-segmentation can be reduced. Experimental results on publicly accessible datasets of dermoscopic and optic disc images demonstrate that the proposed method effectively detects the borders of the objects of interest.
Resumo:
Among Caucasians, it is well known that 75-95% of primary glaucoma is due to open-angle glaucoma (POAG), with angle-closure (PACG) comprising only a very small minority of cases. These figures are reversed among other groups such as Asians and Eskimos, where PACG makes up 80-90% of primary glaucoma. Among Eskimos, the prevalence of PACG has been reported as 2-8%, as compared to 0.1% among Caucasians. It appears that a population tendency toward shallow anterior chambers may explain the excess burden of PACG morbidity. Among Asians, the prevalence of PACG is intermediate between Caucasians and Eskimos. Existing biometrical data do not show a clear tendency toward shallower anterior chambers among Asians. PACG may be screened for on a population basis by means of various techniques that estimate axial or limbal anterior chamber depth, measure intraocular pressure, or evaluate the optic disc or visual fields. Demographic information and medical and family history will also be of great importance in screening for PACG in large populations. Groups at increased risk for the disease include women, individuals over 50, first-degree relatives of PACG probands, and hyperopes.