12 resultados para multiple measurements
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Background: AGI004 is a controlled-release transdermal patch preparation of mecamylamine. We conducted a randomised placebo-controlled phase II study of two dose levels of AGI004 in chemotherapy-induced diarrhoea (CID).
Methods: Adult patients receiving chemotherapy who had experienced diarrhoea (NCI grade 1-2) during previous cycles of chemotherapy were eligible. In all, 64 patients were randomised to receive AGI004 4mg then 8mg per 24 h transdermal patch or placebo for two sequential cycles of chemotherapy. Patients' severity of diarrhoea was physician-assessed using NCI grade of diarrhoea and patient-assessed using information recorded in daily diaries of bowel movements.
Results: Overall AGI004 doubled the odds of a response to treatment on the first day of chemotherapy based on physician assessment of NCI grade of diarrhoea compared with placebo (odds ratio = 2.0, 90% confidence interval: 0.9-4.5) and there was a trend to improved response rates for AGI004 for the full treatment cycle although these results were not statistically significant. There was also evidence of significantly improved response rates based on patient assessment of diarrhoea both overall (P = 0.05) and at the 8-mg dose level (P = 0.02) compared with placebo.
Conclusion: AGI004 demonstrated effectiveness in reducing chemotherapy-associated diarrhoea, with results suggesting response across multiple measurements of diarrhoea. Treatment was well tolerated with no drug-related adverse events. Further evaluation of this agent in the management of CID is warranted.
Resumo:
1. Quantitative reconstruction of past vegetation distribution and abundance from sedimentary pollen records provides an important baseline for understanding long term ecosystem dynamics and for the calibration of earth system process models such as regional-scale climate models, widely used to predict future environmental change. Most current approaches assume that the amount of pollen produced by each vegetation type, usually expressed as a relative pollen productivity term, is constant in space and time.
2. Estimates of relative pollen productivity can be extracted from extended R-value analysis (Parsons and Prentice, 1981) using comparisons between pollen assemblages deposited into sedimentary contexts, such as moss polsters, and measurements of the present day vegetation cover around the sampled location. Vegetation survey method has been shown to have a profound effect on estimates of model parameters (Bunting and Hjelle, 2010), therefore a standard method is an essential pre-requisite for testing some of the key assumptions of pollen-based reconstruction of past vegetation; such as the assumption that relative pollen productivity is effectively constant in space and time within a region or biome.
3. This paper systematically reviews the assumptions and methodology underlying current models of pollen dispersal and deposition, and thereby identifies the key characteristics of an effective vegetation survey method for estimating relative pollen productivity in a range of landscape contexts.
4. It then presents the methodology used in a current research project, developed during a practitioner workshop. The method selected is pragmatic, designed to be replicable by different research groups, usable in a wide range of habitats, and requiring minimum effort to collect adequate data for model calibration rather than representing some ideal or required approach. Using this common methodology will allow project members to collect multiple measurements of relative pollen productivity for major plant taxa from several northern European locations in order to test the assumption of uniformity of these values within the climatic range of the main taxa recorded in pollen records from the region.
Resumo:
Channel randomness can be exploited to generate secret keys. However, to ensure secrecy, it is necessary that the channel response of any eavesdropping party remain sufficiently de-correlated with that of the legitimate users'. In this paper, we investigate whether such de-correlation occurs for a body area network (BAN) operating in an indoor environment at 2.45 GHz. The hypothetical BAN configuration consisted of two legitimate transceivers, one situated on the user's left wrist and the other on the user's waist. The eavesdroppers were positioned in either a co-located or distributed manner in the area surrounding the BAN user. Using the simultaneous channel response measured at the legitimate BAN nodes and the eavesdropper positions for stationary and mobile scenarios, we analyze the localized correlation coefficient. This allows us to determine if it is possible to generate secret keys in the presence of multiple eavesdroppers in an indoor environment. Our experimental results show that although channel reciprocity was observed for both the stationary and the mobile scenarios, a higher de-correlation between the legitimate users' channels was observed for the stationary case. This indicates that mobile scenarios are better suited for secret key generation.
Resumo:
We present two strategies to enhance the dynamical entanglement transfer from continuous-variable (CV) to finite-dimensional systems by employing multiple qubits. First, we consider the entanglement transfer to a composite finite-dimensional system of many qubits simultaneously interacting with a bipartite CV field. We show that, considering realistic conditions in the generation of CV entanglement, a small number of qubits resonantly coupled to the CV system are sufficient for an almost complete dynamical transfer of the entanglement. Our analysis also sheds further light on the transition between the microscopic and macroscopic behaviors of composite finite-dimensional systems coupled to bosonic fields (like atomic clouds interacting with light). Furthermore, we present a protocol based on sequential interactions of the CV system with some ancillary qubit systems and on subsequent measurements, allowing us to probabilistically convert CV entanglement into "almost-perfect" Bell pairs of two qubits. Our proposals are suited for realizations in various experimental settings, ranging from cavity-QED to cavity-integrated superconducting devices.
Resumo:
Reported herein are measured absolute single, double, and triple charge exchange (CE) cross sections for the highly charged ions (HCIs) Cq+ (q=5,6), Oq+ (q=6,7,8), and Neq+ (q=7,8) colliding with the molecular species H2O, CO, and CO2. Present data can be applied to interpreting observations of x-ray emissions from comets as they interact with the solar wind. As such, the ion impact energies of 7.0q keV (1.62–3.06 keV/amu) are representative of the fast solar wind, and data at 1.5q keV for O6+ (0.56 keV/amu) on CO and CO2 and 3.5q keV for O5+ (1.09 keV/amu) on CO provide checks of the energy dependence of the cross sections at intermediate and typical slow solar wind velocities. The HCIs are generated within a 14 GHz electron cyclotron resonance ion source. Absolute CE measurements are made using a retarding potential energy analyzer, with measurement of the target gas cell pressure and incident and final ion currents. Trends in the cross sections are discussed in light of the classical overbarrier model (OBM), extended OBM, and with recent results of the classical trajectory Monte Carlo theory.
Resumo:
This paper presents a systematic measurement campaign of diversity reception techniques for use in multiple-antenna wearable systems operating at 868 MHz. The experiments were performed using six time-synchronized bodyworn receivers and considered mobile off-body communications in an anechoic chamber, open office area and a hallway. The cross-correlation coefficient between the signal fading measured by bodyworn receivers was dependent upon the local environment and typically below 0.7. All received signal envelopes were combined in post-processing to study the potential benefits of implementing receiver diversity based upon selection combination, equal-gain and maximal-ratio combining. It is shown that, in an open office area, the 5.7 dB diversity gain obtained using a dual-branch bodyworn maximal-ratio diversity system may be further improved to 11.1 dB if a six-branch system was used. First-and second-order theoretical equations for diversity reception techniques operating in Nakagami fading conditions were used to model the postdetection combined envelopes. Maximum likelihood estimates of the Nakagami-parameter suggest that the fading conditions encountered in this study were generally less severe than Rayleigh. The paper also describes an algorithm that may be used to simulate the measured output of an M-branch diversity combiner operating in independent and identically-distributed Nakagami fading environments.
Resumo:
Methods of measuring the acoustic behavior of tubular systems can be broadly characterized as steady state measurements, where the measured signals are analyzed in terms of infinite duration sinusoids, and reflectometry measurements which exploit causality to separate the forward and backward going waves in a duct. This paper sets out a multiple microphone reflectometry technique which performs wave separation by using time domain convolution to track the forward and backward going waves in a cylindrical source tube. The current work uses two calibration runs (one for forward going waves and one for backward going waves) to measure the time domain transfer functions for each pair of microphones. These time domain transfer functions encode the time delay, frequency dependent losses and microphone gain ratios for travel between microphones. This approach is applied to the measurement of wave separation, bore profile and input impedance. The work differs from existing frequency domain methods in that it combines the information of multiple microphones within a time domain algorithm, and differs from existing time domain methods in its inclusion of the effect of losses and gain ratios in intermicrophone transfer functions.
Resumo:
A novel diagnostic technique for the measurement of negative ions is presented. The absorption of a cw-laser beam with a wavelength close to the maximum of the photodetachment cross section is measured. The laser beam undergoes multiple reflections through the discharge volume using a multipass cell there a Herriott arrangement). Proof-of-principle measurements of negative hydrogen ions in a hybrid volume source are presented. The measured H- density is in agreement with results of conventional, Langmuir probe-based photodetachment measurements. (C) 1998 American Institute of Physics. [S0003-6951(98)02119-6].
Resumo:
We propose a complete application capable of tracking multiple objects in an environment monitored by multiple cameras. The system has been specially developed to be applied to sport games, and it has been evaluated in a real association-football stadium. Each target is tracked using a local importance-sampling particle filter in each camera, but the final estimation is made by combining information from the other cameras using a modified unscented Kalman filter algorithm. Multicamera integration enables us to compensate for bad measurements or occlusions in some cameras thanks to the other views it offers. The final algorithm results in a more accurate system with a lower failure rate. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3114605]
Resumo:
This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.
Resumo:
Objective: To evaluate temporal changes in GCF levels of substance P, cathepsin G, interleukin 1 beta (IL-1&beta), neutrophil elastase and alpha1-antitrypsin (&alpha1AT) during development of and recovery from experimental gingivitis. Methods: Healthy human volunteers participated in a split-mouth study: experimental gingivitis was induced using a soft vinyl splint to cover test teeth during brushing over 21 days, after which normal brushing was resumed. Modified gingival index (MGI), gingival bleeding index (BI) and modified Quigley and Hein plaque index (PI) were assessed and 30-second GCF samples taken from 4 paired test and contra-lateral control sites in each subject at days 0, 7, 14, 21, 28 and 42. GCF volume was measured and site-specific quantification of one analyte per GCF sample was performed using radioimmunoassay (substance P), enzyme assay (cathepsin G) or ELISA (IL-1&beta, elastase, &alpha1AT). Site-specific data were analysed using analysis of repeated measurements and paired sample tests. Results: 56 subjects completed the study. All measurements at baseline (day 0) and at control sites throughout the study were low. Clinical indices and GCF volumes at the test sites increased from day 0, peaking at day 21 (difference between test and control for PI, BI, MGI and GCF all p<0.0001) and decreased again to control levels by day 28. Levels of four inflammatory markers showed a similar pattern, with significant differences between test and control apparent at 7 days (substance P p=0.0015; cathepsin G p=0.029; IL-1&beta p=0.026; elastase p=0.0129) and peaking at day 21 (substance P p=0.0023; cathepsin G, IL-1&beta and elastase all p<0.0001). Levels of &alpha1AT showed no apparent pattern over the course of the study. Conclusion: GCF levels of substance P, cathepsin G, IL-1&beta and neutrophil elastase have the potential to act as early markers of experimentally-induced gingival inflammation.
Resumo:
This paper proposes a method for the detection and classification of multiple events in an electrical power system in real-time, namely; islanding, high frequency events (loss of load) and low frequency events (loss of generation). This method is based on principal component analysis of frequency measurements and employs a moving window approach to combat the time-varying nature of power systems, thereby increasing overall situational awareness of the power system. Numerical case studies using both real data, collected from the UK power system, and simulated case studies, constructed using DigSilent PowerFactory, for islanding events, as well as both loss of load and generation dip events, are used to demonstrate the reliability of the proposed method.