99 resultados para minimum angle

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate "in vivo" safety of trypan blue (TB) in patients undergoing TB-assisted internal limiting membrane or epiretinal membrane peeling. Methods: Prospective study including 21 patients (21 eyes) with full-thickness macular hole and/or epiretinal membrane undergoing TB-assisted internal limiting membrane/epiretinal membrane peeling. Main outcome measures included distance visual acuity, near visual acuity, amplitude of P50 and N95 of the pattern electroretinogram, and fundus autofluorescence; these were assessed preoperatively, at 6 months (n = 21) and 12 months (n = 10) postoperatively. Results: There was a statistically significant improvement in distance visual acuity, near visual acuity, P50, and N95 amplitude at 6 months and 12 months postoperatively. The mean logarithm of the minimum angle of resolution distance visual acuity and near visual acuity improved from baseline by 0.31 (SD 0.37) and 0.17 (SD 0.31) at 6 months, respectively, and by 0.4 (SD 0.25) and 0.35 (SD 0.28) at 12 months, respectively. The mean P50 and N95 component amplitudes improved by 28% compared with baseline at 6 months (P50 0.4 [SD 0.8]; N95 0.53 [SD 1.07]) and by 63% at 12 months (P50 0.9 [0.85]; N95 1.04 [1.34]). Autofluorescence did not demonstrate damage to the retinal pigment epithelium attributable to TB. Conclusion: No deleterious effects of TB were observed in this study. Copyright © 2011 Lippincott Williams &Wilkins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To estimate the prevalence, potential determinants, and proportion of met need for near vision impairment (NVI) correctable with refraction approximately 2 years after initial examination of a multi-country cohort. Design: Population-based, prospective cohort study. Participants: People aged ≥35 years examined at baseline in semi-rural (Shunyi) and urban (Guangzhou) sites in China; rural sites in Nepal (Kaski), India (Madurai), and Niger (Dosso); a semi-urban site (Durban) in South Africa; and an urban site (Los Angeles) in the United States. Methods: Near visual acuity (NVA) with and without current near correction was measured at 40 cm using a logarithm of the minimum angle of resolution near vision tumbling E chart. Participants with uncorrected binocular NVA ≤20/40 were tested with plus sphere lenses to obtain best-corrected binocular NVA. Main Outcome Measures: Prevalence of total NVI (defined as uncorrected NVA ≤20/40) and NVI correctable and uncorrectable to >20/40, and current spectacle wearing among those with bilateral NVA ≤20/63 improving to >20/40 with near correction (met need). Results: Among 13 671 baseline participants, 10 533 (77.2%) attended the follow-up examination. The prevalence of correctable NVI increased with age from 35 to 50-60 years and then decreased at all sites. Multiple logistic regression modeling suggested that correctable NVI was not associated with gender at any site, whereas more educated persons aged >54 years were associated with a higher prevalence of correctable NVI in Nepal and India. Although near vision spectacles were provided free at baseline, wear among those who could benefit was <40% at all but 2 centers (Guangzhou and Los Angeles). Conclusions: Prevalence of correctable NVI is greatest among persons of working age, and rates of correction are low in many settings, suggesting that strategies targeting the workplace may be needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impedance and radiation pattern parameters of a lambda/2 quadrifilar helix antenna (QHA) with turn angles in the range 0 degrees to 235 degrees are analyzed. It is shown that by selecting the helix turn angle to satisfy the minimum bandwidth and beamwidth requirements, an improved electrical performance and a reduction in the physical size of the antenna is obtained. This is demonstrated by comparing the performance of a conventional half turn QHA with structures having a smaller pitch length. The computed results are validated by experimental data at L-band.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the changes in the Visual Field Index (VFI) in eyes with perimetric glaucomatous progression, and to compare these against stable glaucoma patients.

PATIENTS AND METHODS: Consecutive patients with open angle glaucoma with a minimum of 6 reliable visual fields and 2 years of follow-up were identified. Perimetric progression was assessed by 4 masked glaucoma experts from different units, and classified into 3 categories: "definite progression," "suspected progression," or "no progression." This was compared with the Glaucoma Progression Analysis (GPA) II and VFI linear regression analysis, where progression was defined as a negative slope with significance of <5%.

RESULTS: Three hundred ninety-seven visual fields from 51 eyes of 39 patients were assessed. The mean number of visual fields was 7.8 (SD 1.1) per eye, and the mean follow-up duration was 63.7 (SD 13.4) months. The mean VFI linear regression slope showed an overall statistically significant difference (P<0.001, analysis of variance) for each category of progression. Using expert consensus opinion as the reference standard, both VFI analysis and GPA II had high specificity (0.93 and 0.90, respectively), but relatively low sensitivity (0.45 and 0.41, respectively).

CONCLUSIONS: The mean VFI regression slope in our cohort of eyes without perimetric progression showed a statistically significant difference compared with those with suspected and definite progression. VFI analysis and GPA II both had similarly high specificity but low sensitivity when compared with expert consensus opinion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel wide angle spectrometer has been implemented with a highly oriented pyrolytic graphite crystal coupled to an image plate. This spectrometer has allowed us to look at the energy resolved spectrum of scattered x rays from a dense plasma over a wide range of angles ( ~ 30°) in a single shot. Using this spectrometer we were able to observe the temporal evolution of the angular scatter cross section from a laser shocked foil. A spectrometer of this type may also be useful in investigations of x-ray line transfer from laser-plasmas experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Support vector machine (SVM) is a powerful technique for data classification. Despite of its good theoretic foundations and high classification accuracy, normal SVM is not suitable for classification of large data sets, because the training complexity of SVM is highly dependent on the size of data set. This paper presents a novel SVM classification approach for large data sets by using minimum enclosing ball clustering. After the training data are partitioned by the proposed clustering method, the centers of the clusters are used for the first time SVM classification. Then we use the clusters whose centers are support vectors or those clusters which have different classes to perform the second time SVM classification. In this stage most data are removed. Several experimental results show that the approach proposed in this paper has good classification accuracy compared with classic SVM while the training is significantly faster than several other SVM classifiers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchronisation of small distributed generation, 30 kVA–2 MVA, employing salient-pole synchronous machines is normally performed within a narrow range of tolerances for voltage, frequency and phase angle. However, there are situations when the ability to synchronise with non-ideal conditions would be beneficial. Such applications include power system islanding and rapid generator start-up. The physical process and effect of out-of-phase synchronisation is investigated both through simulation and experimental tests on a salient-pole alternator. There are many factors that affect synchronisation, but particular attention is given to synchronisation angle, voltage difference and, as generators will be loaded during islanding, the load angle. The results suggest that it would be acceptable for the maximum synchronisation angle of distributed generation to exceed that of current practice. Interesting observations on the nature of out-of-phase synchronisation are made, including some specific to small salient-pole synchronous machines. Furthermore, recommendations are made for synchronisation under different system conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper compares the structure of 1-alkyl-3-methylim ridazolium salts using SAXS and X-ray reflectivity. A range of anions have been investigated namely chloride, bromide, trifluoromethanesulfonate (OTf), bis(trifluoromethanesulfonyl)imide (TFI) and tetrachloropalladate(II) with cation alkyl chains ranging from n = 12-20. In general, the salts show liquid crystalline behaviour whose structure is still observed on melting into an isotropic liquid.