72 resultados para mechanical ventilation
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Background:
Internationally, nurse-directed protocolised-weaning has been evaluated by measuring its impact on patient outcomes. The impact on nurses’ views and perceptions has been largely ignored.
Aim:
To determine the change in intensive care nurses’ perceptions, satisfaction, knowledge and attitudes following the introduction of nurse-directed weaning. Additionally, views were obtained on how useful protocolised-weaning was to practice.
Methods:
The sample comprised nurses working in general intensive care units in three university-affiliated hospitals. Nurse-directed protocolised-weaning was implemented in one unit (intervention group); two ICUs continued with usual doctor-led practice (control group). Nurses’ perceptions, satisfaction, knowledge and attitudes were measured by self-completed questionnaires before (Phase I) and after the implementation of nurse-directed weaning (Phase II) in all units.
Results:
Response rates were 79% (n=140n=140) for Phase 1 and 62% (n=132n=132) for Phase II. Regression-based analyses showed that changes from Phase I to Phase II were not significantly different between the intervention and control groups. Sixty-nine nurses responded to both Phase I and II questionnaires. In the intervention group, these nurses scored their mean perceived level of knowledge higher in Phase II (6.39 vs 7.17, p=0.01p=0.01). In the control group, role perception (4.41 vs 4.22, p=0.01p=0.01) was lower and, perceived knowledge (6.03 vs 6.63, p=0.04p=0.04), awareness of weaning plans (6.09 vs 7.06, p=0.01p=0.01) and satisfaction with communication (5.28 vs 6.19, p=0.01p=0.01) were higher in Phase II. The intervention group found protocolised weaning useful in their practice (75%): this was scored significantly higher by junior and senior nurses than middle grade nurses (p=0.02p=0.02).
Conclusion
We conclude that nurse-directed protocolised-weaning had no effect on nurses’ views and perceptions due to the high level of satisfaction which encouraged nurses’ participation in weaning throughout. Control group changes are attributed to a ‘reactive effect’ from being study participants. Weaning protocols provide a uniform method of weaning practice and are particularly beneficial in providing safe guidance for junior staff.
Resumo:
Using a before and after study design, we compared protocolised weaning from mechanical ventilation with usual non-protocolised practice in intensive care. Outcomes (duration of mechanical ventilation, duration of intubation, intensive care stay) and complications (re-intubations, tracheostomy, mortality) were compared between baseline (Phase I) and following implementation of protocolised weaning (Phase II). Over the same period, we collected data in a second (reference) unit to monitor practice changes over time. In the intervention unit, outcomes were longer in Phase II compared with Phase I (all p < 0.005). When adjusted for admission APACHE II score and diagnostic category, only intensive care stay remained significantly longer (p = 0.002). There were significantly more tracheostomies in Phase II (p = 0.004). The reference unit demonstrated no statistically significant differences in study outcomes or complications between Phases. Protocolised weaning did not reduce the duration of mechanical ventilation and was not associated with an increased rate of re-intubation or intensive care unit mortality.
Resumo:
Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.
Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.
Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.
Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).
Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.
Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.
Resumo:
Objective To investigate the effects of weaning protocols on the total duration of mechanical ventilation, mortality, adverse events, quality of life, weaning duration, and length of stay in the intensive care unit and hospital.
Design Systematic review.
Data sources Cochrane Central Register of Controlled Trials, Medline, Embase, CINAHL, LILACS, ISI Web of Science, ISI Conference Proceedings, Cambridge Scientific Abstracts, and reference lists of articles. We did not apply language restrictions.
Review methods We included randomised and quasi-randomised controlled trials of weaning from mechanical ventilation with and without protocols in critically ill adults.
Data selection Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.
Results Eleven trials that included 1971 patients met the inclusion criteria. Compared with usual care, the geometric mean duration of mechanical ventilation in the weaning protocol group was reduced by 25% (95% confidence interval 9% to 39%, P=0.006; 10 trials); the duration of weaning was reduced by 78% (31% to 93%, P=0.009; six trials); and stay in the intensive care unit length by 10% (2% to 19%, P=0.02; eight trials). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2)=76%, P
Conclusion There is evidence of a reduction in the duration of mechanical ventilation, weaning, and stay in the intensive care unit when standardised weaning protocols are used, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Some studies suggest that organisational context could influence outcomes, but this could not be evaluated as it was outside the scope of this review.
Resumo:
Background
Recently, clinical and research attention has been focused on refining weaning processes to improve outcomes for critically ill patients who require mechanical ventilation. One such process, use of a weaning protocol, has yielded conflicting results, arguably because of the influence of existing context and processes.
Objective
To compare international data to assess differences in context and processes in intensive care units that could influence weaning.
Methods
Review of existing national data on provision of care for critically ill patients, including structure, staffing, skill mix, education, roles, and responsibilities for weaning in intensive care units of selected countries.
Results
Australia, New Zealand, Denmark, Norway, Sweden, and the United Kingdom showed similarities in critical care provision, structure, skill mix, and staffing ratios in intensive care units. Weaning in these countries is generally a collaborative process between nurses and physicians. Notable differences in intensive care units in the United States were the frequent use of an open structure and inclusion of respiratory therapists on the intensive care unit’s health care team. Nurses may be excluded from direct management of ventilator weaning in some institutions, as this role is primarily assumed by respiratory therapists guided by medical directives. Availability of critical care beds was highest in the United States and lowest in the United Kingdom.
Conclusion
Context and processes of care that could influence ventilator weaning outcomes varied considerably across countries. Further quantification of these contextual influences should be considered when translating research findings into local clinical practice and when designing randomized, controlled trials.
Resumo:
Abstract
Background: Automated closed loop systems may improve adaptation of the mechanical support to a patient's ventilatory needs and
facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of
ventilation.
Objectives: To compare the duration of weaning from mechanical ventilation for critically ill ventilated adults and children when managed
with automated closed loop systems versus non-automated strategies. Secondary objectives were to determine differences
in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.
Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2); MEDLINE (OvidSP) (1948 to August 2011); EMBASE (OvidSP) (1980 to August 2011); CINAHL (EBSCOhost) (1982 to August 2011); and the Latin American and Caribbean Health Sciences Literature (LILACS). In addition we received and reviewed auto-alerts for our search strategy in MEDLINE, EMBASE, and CINAHL up to August 2012. Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles.
Selection criteria: We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning
strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an intensive care unit (ICU).
Data collection and analysis: Two authors independently extracted study data and assessed risk of bias. We combined data into forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria.
Main results: Pooled data from 15 eligible trials (14 adult, one paediatric) totalling 1173 participants (1143 adults, 30 children) indicated that automated closed loop systems reduced the geometric mean duration of weaning by 32% (95% CI 19% to 46%, P =0.002), however heterogeneity was substantial (I2 = 89%, P < 0.00001). Reduced weaning duration was found with mixed or
medical ICU populations (43%, 95% CI 8% to 65%, P = 0.02) and Smartcare/PS™ (31%, 95% CI 7% to 49%, P = 0.02) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (17%, 95% CI 8% to 26%) and ICU length of stay (LOS) (11%, 95% CI 0% to 21%). There was no difference in mortality rates or hospital LOS. Overall the quality of evidence was high with the majority of trials rated as low risk.
Authors' conclusions: Automated closed loop systems may result in reduced duration of weaning, ventilation, and ICU stay. Reductions are more
likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized
controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.