12 resultados para loss detection

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper considers the enhancement of loss-of-mains detection by use of a differential rate-of-change-of-frequency relay to reduce nuisance tripping and improve sensitivity to small excursions in frequency. The telecommunications media which might carry the differential ROCOF signal are reviewed with a focus on channel latency, bandwidth and security.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper discusses methods of using the Internet as a communications media between distributed generator sites to provide new forms of loss-of-mains protection. An analysis of the quality of the communications channels between several nodes on the network was carried out experimentally. It is shown that Internet connections in urban environments are already capable of providing real-time power system protection, whilst rural Internet connections are borderline suitable but could not yet be recommended as a primary method of protection. Two strategies of providing loss-of-mains across Internet protocol are considered, broadcast of a reference frequency or phasor representing the utility and an Internet based inter-tripping scheme.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, our previous work on Principal Component Analysis (PCA) based fault detection method is extended to the dynamic monitoring and detection of loss-of-main in power systems using wide-area synchrophasor measurements. In the previous work, a static PCA model was built and verified to be capable of detecting and extracting system faulty events; however the false alarm rate is high. To address this problem, this paper uses a well-known ‘time lag shift’ method to include dynamic behavior of the PCA model based on the synchronized measurements from Phasor Measurement Units (PMU), which is named as the Dynamic Principal Component Analysis (DPCA). Compared with the static PCA approach as well as the traditional passive mechanisms of loss-of-main detection, the proposed DPCA procedure describes how the synchrophasors are linearly
auto- and cross-correlated, based on conducting the singular value decomposition on the augmented time lagged synchrophasor matrix. Similar to the static PCA method, two statistics, namely T2 and Q with confidence limits are calculated to form intuitive charts for engineers or operators to monitor the loss-of-main situation in real time. The effectiveness of the proposed methodology is evaluated on the loss-of-main monitoring of a real system, where the historic data are recorded from PMUs installed in several locations in the UK/Ireland power system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid and sensitive immuno-based screening method was developed to detect domoic acid (DA) present in extracts of shellfish species using a surface plasmon resonance-based optical biosensor. A rabbit polyclonal antibody raised against DA was mixed with standard or sample extracts and allowed to interact with DA immobilized onto a sensor chip surface. The characterization of the antibody strongly suggested high cross-reactivity with DA and important isomers of the toxin. The binding of this antibody to the sensor chip surface was inhibited in the presence of DA in either standard solutions or sample extracts. The DA chip surface proved to be highly stable, achieving approximately 800 analyses per chip without any loss of surface activity. A single analytical cycle (sample injection, chip regeneration, and system wash) took 10 min to complete. Sample analysis (scallops, mussels, cockles, oysters) was achieved by simple extraction with methanol. These extracts were then filtered and diluted before analysis. Detection limits in the ng/g range were achieved by the assay; however, the assay parameters chosen allowed the test to be performed most accurately at the European Union's official action limit for DA of 20 mu g/g. At this concentration, intra- and interassay variations were measured for a range of shellfish species and ranged from 4.5 to 7.4% and 2.3 to 9.7%, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arsenic volatilization in the environment is thought to be an important pathway for transfer from terrestrial pools to the atmosphere. However, this phenomenon is not well characterized due to inherent sampling issues in trapping, quantifying and qualifying these arsine gases; including arsine (AsH(3)), monomethyl arsine (MeAsH(2)), dimethyl arsine (Me(2)AsH) and trimethyl arsine (TMAs). To quantify and qualify arsines in air we developed a novel technique based on silver nitrate impregnated silica gel filled tubes. The method was characterized by measuring the recovery of trapped arsines after elution of this chemo-trap with hot boiling diluted nitric acid. Results from three separate experiments, measured by ICP-MS, showed that the method is reproducible and quantitative. Arsine species recovery ranged from 80.1 to 95.6%, with limit of detection as low as 3.8 ng per chemo-trap tube. Moreover, HPLC-ICP-MS analysis of hot boiling water eluted traps showed that the corresponding oxy ions of the arsines were formed with the As-C bonds of the molecule intact, hence, allowing qualification of trapped arsine species. A microcosm study examining volatile arsenic evolution from field contaminated Bangladeshi paddy soils (24.2 mg/kg arsenic) was used to show the application of silver nitrate chemo-trapping approach. Traps were placed on the inlet and the outlet of microcosms containing the soils that were either (cattle derived) manured or not, or flooded or not, in a factorial design. The headspace was purged with air at a flow rate of 12 mL/min. Results showed that as much as 320 ng of arsenic (0.014% of total soil content) could be emitted in a 3 week period for manured and flooded soils and that TMAs was the dominant species evolved, with lesser quantities of Me(2)AsH. No volatile arsenic evolution was observed for nonmanured treatments, and arsine release from the nonflooded, manured treatment was much less than the flooded treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel multiplexed immunoassay for the analysis of phycotoxins in shellfish samples has been developed. Therefore, a regenerable chemiluminescence (CL) microarray was established which is able to analyze automatically three different phycotoxins (domoic acid (DA), okadaic acid (OA) and saxitoxin (STX)) in parallel on the analysis platform MCR3. As a test format an indirect competitive immunoassay format was applied. These phycotoxins were directly immobilized on an epoxy-activated PEG chip surface. The parallel analysis was enabled by the simultaneous addition of all analytes and specific antibodies on one microarray chip. After the competitive reaction, the CL signal was recorded by a CCD camera. Due to the ability to regenerate the toxin microarray, internal calibrations of phycotoxins in parallel were performed using the same microarray chip, which was suitable for 25 consecutive measurements. For the three target phycotoxins multi-analyte calibration curves were generated. In extracted shellfish matrix, the determined LODs for DA, OA and STX with values of 0.5±0.3 µg L(-1), 1.0±0.6 µg L(-1), and 0.4±0.2 µg L(-1) were slightly lower than in PBS buffer. For determination of toxin recoveries, the observed signal loss in the regeneration was corrected. After applying mathematical corrections spiked shellfish samples were quantified with recoveries for DA, OA, and STX of 86.2%, 102.5%, and 61.6%, respectively, in 20 min. This is the first demonstration of an antibody based phycotoxin microarray.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Loss-of-mains protection is an important component of the protection systems of embedded generation. The role of loss-of-mains is to disconnect the embedded generator from the utility grid in the event that connection to utility dispatched generation is lost. This is necessary for a number of reasons, including the safety of personnel during fault restoration and the protection of plant against out-of-synchronism reclosure to the mains supply. The incumbent methods of loss-of-mains protection were designed when the installed capacity of embedded generation was low, and known problems with nuisance tripping of the devices were considered acceptable because of the insignificant consequence to system operation. With the dramatic increase in the installed capacity of embedded generation over the last decade, the limitations of current islanding detection methods are no longer acceptable. This study describes a new method of loss-of-mains protection based on phasor measurement unit (PMU) technology, specifically using a low cost PMU device of the authors' design which has been developed for distribution network applications. The proposed method addresses the limitations of the incumbent methods, providing a solution that is free of nuisance tripping and has a zero non-detection zone. This system has been tested experimentally and is shown to be practical, feasible and effective. Threshold settings for the new method are recommended based on data acquired from both the Great Britain and Ireland power systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple derivatization methodology is shown to extend the application of surface-enhanced Raman spectroscopy (SERS) to the detection of trace concentration of contaminants in liquid form. Normally in SERS the target analyte species is already present in the molecular form in which it is to be detected and is extracted from solution to occupy sites of enhanced electromagnetic field on the substrate by means of chemisorption or drop-casting and subsequent evaporation of the solvent. However, these methods are very ineffective for the detection of low concentrations of contaminant in liquid form because the target (ionic) species (a) exhibits extremely low occupancy of enhancing surface sites in the bulk liquid environment and (b) coevaporates with the solvent. In this study, the target analyte species (acid) is detected via its solid derivative (salt) offering very significant enhancement of the SERS signal because of preferential deposition of the salt at the enhancing surface but without loss of chemical discrimination. The detection of nitric acid and sulfuric acid is demonstrated down to 100 ppb via reaction with ammonium hydroxide to produce the corresponding ammonium salt. This yields an improvement of ∼4 orders of magnitude in the low-concentration detection limit compared with liquid phase detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the GALEX detection of a UV burst at the time of explosion of an optically normal supernova (SN) IIP (PS1-13arp) from the Pan-STARRS1 survey at z = 0.1665. The temperature and luminosity of the UV burst match the theoretical predictions for shock breakout in a red supergiant (RSG), but with a duration a factor of similar to 50 longer than expected. We compare the NUV light curve of PS1-13arp to previous GALEX detections of SNe IIP and find clear distinctions that indicate that the UV emission is powered by shock breakout, and not by the subsequent cooling envelope emission previously detected in these systems. We interpret the similar to 1 day duration of the UV signal with a shock breakout in the wind of an RSG with a pre-explosion mass-loss rate of similar to 10(-3) M-circle dot yr(-1). This mass-loss rate is enough to prolong the duration of the shock breakout signal, but not enough to produce an excess in the optical plateau light curve or narrow emission lines powered by circumstellar interaction. This detection of nonstandard, potentially episodic high mass loss in an RSG SN progenitor has favorable consequences for the prospects of future wide-field UV surveys to detect shock breakout directly in these systems, and provide a sensitive probe of the pre-explosion conditions of SN progenitors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multicarrier Index Keying (MCIK) is a recently developed technique that modulates subcarriers but also indices of the subcarriers. In this paper a novel low-complexity detection scheme of subcarrier indices is proposed for an MCIK system and addresses a substantial reduction in complexity over the optimalmaximum likelihood (ML) detection. For the performance evaluation, a closed-form expression for the pairwise error probability (PEP) of an active subcarrier index, and a tight approximation of the average PEP of multiple subcarrier indices are derived in closed-form. The theoretical outcomes are validated usingsimulations, at a difference of less than 0.1dB. Compared to the optimal ML, the proposed detection achieves a substantial reduction in complexity with small loss in error performance (<= 0.6dB).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a method for the detection and classification of multiple events in an electrical power system in real-time, namely; islanding, high frequency events (loss of load) and low frequency events (loss of generation). This method is based on principal component analysis of frequency measurements and employs a moving window approach to combat the time-varying nature of power systems, thereby increasing overall situational awareness of the power system. Numerical case studies using both real data, collected from the UK power system, and simulated case studies, constructed using DigSilent PowerFactory, for islanding events, as well as both loss of load and generation dip events, are used to demonstrate the reliability of the proposed method.