102 resultados para interface slip
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
A finite element model is developed to predict the stress-strain behaviour of particulate composites with fully unbonded filler particles. This condition can occur because of the lack of adhesion property of the filler surface. Whilst part of the filler particle is separated from the matrix, another section of filler keeps in contact with the matrix because of the lateral compressive displacement of the matrix. The slip boundary condition is imposed on the section of the interface that remains closed. The states of stress and displacement fields are obtained. The location of any further deformation through crazing or shear band formation is identified. A completely unbonded inclusion with partial slip at a section of the interface reduces the concentration of the stress at the interface significantly. Whereas this might lead to slightly higher strength, it decreases the load transfer efficiency and stiffness of this type of composite.
Resumo:
The objectives of this study were to determine the fracture toughness of adhesive interfaces between dentine and clinically relevant, thin layers of dental luting cements. Cements tested included a conventional glass-ionomer, F (Fuji I), a resin-modified glass-ionomer, FP (Fuji Plus) and a compomer cement, D (DyractCem). Ten miniature short-bar chevron notch specimens were manufactured for each cement, each comprising a 40 µm thick chevron of lute, between two 1.5 mm thick blocks of bovine dentine, encased in resin composite. The interfacial KIC results (MN/m3/2) were median (range): F; 0.152 (0.14-0.16), FP; 0.306 (0.27-0.37), D; 0.351 (0.31-0.37). Non-parametric statistical analysis showed that the fracture toughness of F was significantly lower (p
Resumo:
Calibration is essential for interpretation of radiocarbon dates, especially when the 14C dates are compared to historical or climatic records with a different chronological basis. 14C ages of samples from the marine environment, such as shells or fish bones, or samples with a marine component, such as human bone in coastal regions, require an additional consideration because of the reservoir age of the ocean. While the pre-industrial global mean reservoir correction, R(t), is about 400 years, local variations (?R) can be several hundred years or more. ?R compilations on a global scale have been undertaken previously (Stuiver et al. 1986; Stuiver and Braziunas 1993), but have not been updated recently. Here we describe an on-line reservoir correction database accessed via mapping software. Rather than publishing a static ?R compilation, new data will be incorporated when it becomes available. The on-line marine reservoir correction database can be accessed at the website http://www.calib.org/.
Entrepreneurial Learning: Researching the Interface between Learning and the Entrepreneurial Context
Resumo:
We have investigated the influence of the material properties of the silicon device layer on the generation of defects, and in particular slip dislocations, in trenched and refilled fusion-bonded silicon-on-insulator structures. A strong dependence of the ease of slip generation on the type of dopant species was observed, with the samples falling into three basic categories; heavily boron-doped silicon showed ready slip generation, arsenic and antimony-doped material was fairly resistant to slip, while silicon moderately or lightly doped with phosphorous or boron gave intermediate behavior. The observed behavior appears to be controlled by differences in the dislocation generation mechanism rather than by dislocation mobility. The introduction of an implanted buried layer at the bonding interface was found to result in an increase in slip generation in the silicon, again with a variation according to the dopant species. Here, the greatest slip occurred for both boron and antimony-implanted samples. The weakening of the implanted material may be related to the presence of a band of precipitates observed in the silicon near the bonding interface. (C) 2001 The Electrochemical Society.
Resumo:
Structural and magnetic properties of thin Mn films on the Fe(001) surface have been investigated by a combination of photoelectron spectroscopy and computer simulation in the temperature range 300 Kless than or equal toTless than or equal to750 K. Room-temperature as deposited Mn overlayers are found to be ferromagnetic up to 2.5-monolayer (ML) coverage, with a magnetic moment parallel to that of the iron substrate. The Mn atomic moment decreases with increasing coverage, and thicker samples (4-ML and 4.5-ML coverage) are antiferromagnetic. Photoemission measurements performed while the system temperature is rising at constant rate (dT/dtsimilar to0.5 K/s) detect the first signs of Mn-Fe interdiffusion at T=450 K, and reveal a broad temperature range (610 Kless than or equal toTless than or equal to680 K) in which the interface appears to be stable. Interdiffusion resumes at Tgreater than or equal to680 K. Molecular dynamics and Monte Carlo simulations allow us to attribute the stability plateau at 610 Kless than or equal toTless than or equal to680 K to the formation of a single-layer MnFe surface alloy with a 2x2 unit cell and a checkerboard distribution of Mn and Fe atoms. X-ray-absorption spectroscopy and analysis of the dichroic signal show that the alloy has a ferromagnetic spin structure, collinear with that of the substrate. The magnetic moments of Mn and Fe atoms in the alloy are estimated to be 0.8mu(B) and 1.1mu(B), respectively.
Resumo:
This paper introduces a novel interface designed to help blind and visually impaired people to explore and navigate on the Web. In contrast to traditionally used assistive tools, such as screen readers and magnifiers, the new interface employs a combination of both audio and haptic features to provide spatial and navigational information to users. The haptic features are presented via a low-cost force feedback mouse allowing blind people to interact with the Web, in a similar fashion to their sighted counterparts. The audio provides navigational and textual information through the use of non-speech sounds and synthesised speech. Interacting with the multimodal interface offers a novel experience to target users, especially to those with total blindness. A series of experiments have been conducted to ascertain the usability of the interface and compare its performance to that of a traditional screen reader. Results have shown the advantages that the new multimodal interface offers blind and visually impaired people. This includes the enhanced perception of the spatial layout of Web pages, and navigation towards elements on a page. Certain issues regarding the design of the haptic and audio features raised in the evaluation are discussed and presented in terms of recommendations for future work.