3 resultados para implant stress

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: The aim of this study was to investigate the factors associated with continued significant tooth loss due to periodontal reasons during maintenance following periodontal therapy in a specialist periodontal practice in Norway.
Material and Methods: A case-control design was used. Refractory cases were patients who lost multiple teeth during a maintenance period of 13.4 (range 8-19) years following definitive periodontal treatment in a specialist practice. Controls were age- and gender-matched maintenance patients from the same practice. Characteristics and treatment outcomes were assessed, and all teeth classified as being lost due to periodontal disease during follow-up were identified. The use of implants in refractory cases and any complications relating to such a treatment were recorded.
Results: Only 27 (2.2%) patients who received periodontal treatment between 1986 and 1998 in a specialist practice met the criteria for inclusion in the refractory to treatment group. Each refractory subject lost 10.4 (range 4-16) teeth, which represented 50% of the teeth present at baseline. The rate of tooth loss in the refractory group was 0.78 teeth per year, which was 35 times greater than that in the control group. Multivariate analysis indicated that being in the refractory group was predicted by heavy smoking (p=0.026), being stressed (p=0.016) or having a family history of periodontitis (p=0.002). Implants were placed in 14 of the refractory patients and nine (64%) of these lost at least one implant. In total, 17 (25%) of the implants placed in the refractory group were lost during the study period.
Conclusions: A small number of periodontal maintenance patients are refractive to treatment and go on to experience significant tooth loss. These subjects also have a high level of implant complications and failure. Heavy smoking, stress and a family history of periodontal disease were identified as factors associated with a refractory outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The majority of cemented femoral hip replacements fail as a consequence of loosening. One design feature that may affect loosening rates is implant surface finish. To determine whether or not surface finish effects fatigue damage accumulation in a bone cement mantle, we developed an experimental model of the implanted proximal femur that allows visualisation of damage growth in the cement layer. Five matt surface and five polished surface stems were tested. Pre-load damage and damage after two million cycles was measured. Levels of pre-load (shrinkage) damage were the same for both matt and polished stems; furthermore damage for matt vs. polished stems was not significantly different after two million cycles. This was due to the large variability in damage accumulation rates. Finite element analysis showed that the stress is higher for the polished (assumed debonded) stem, and therefore we must conclude that either the magnitude of the stress increase is not enough to appreciably increase the damage accumulation rate or, alternatively, the polished stem does not debond immediately from the cement. Significantly (P = 0.05) more damage was initiated in the lateral cement compared to the medial cement for both kinds of surface finish. It was concluded that, despite the higher cement stresses with debonded stems, polished prostheses do not provoke the damage accumulation failure scenario. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Porous titanium samples were manufactured using the 3D printing and sintering method in order to determine the effects of final sintering temperature on morphology and mechanical properties. Cylindrical samples were printed and split into groups according to a final sintering temperature (FST). Irregular geometry samples were also printed and split into groups according to their FST. The cylindrical samples were used to determine part shrinkage, in compressive tests to provide stress-strain data, in microCT scans to provide internal morphology data and for optical microscopy to determine surface morphology. All of the samples were used in microhardness testing to establish the hardness. Below 1100 C FST, shrinkage was in the region of 20% but increased to approximately 30% by a FST of 1300 C. Porosity varied from a maximum of approximately 65% at the surface to the region of 30% internally. Between 97 and 99% of the internal porosity is interconnected. Average pore size varied between 24 µm at the surface and 19 µm internally. Sample hardness increased to in excess of 300 HV0.05 with increasing FST while samples with an FST of below 1250 C produced an elastic-brittle stress/strain curve and samples above this displayed elastic-plastic behaviour. Yield strength increased significantly through the range of sintering temperatures while the Young's modulus remained fairly consistent. © 2013 Elsevier B.V.