64 resultados para hygrothermal conditioning
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
The reported incidence of colonization of oropharyngeal medical devices with Candida spp. has increased in recent years, although few studies that have systematically examined the adherence of yeast cells to such biomaterials, the primary step in the process of colonization. This study, therefore, examined the effects of oropharyngeal atmospheric conditions (5% v/v carbon dioxide) and the presence of a salivary conditioning film on both the surface properties and adherence of Candida albicans, Candida krusei and Candida tropicalis to PVC and silicone. Furthermore, the effects of the salivary conditioning film on the surface properties of these biomaterials are reported. Growth of the three Candida spp. in an atmosphere containing 5% v/v CO2 significantly increased their cell surface hydrophobicity and reduced the zeta potential of C. albicans and C. krusei yet increased the zeta potential of C. tropicalis (p < 0.05). Furthermore, growth in 5% v/v CO2 decreased the adherence of C. tropicalis and C. albicans to both PVC and silicone, however, increased adherence of C. krusei (p < 0.05). Pre-treatment of the microorganisms with pooled human saliva significantly decreased their cell surface hydrophobicity and increased their adherence to either biomaterial in comparison to yeast cells that had been pre-treated with PBS (p < 0.05). Saliva treatment of the microorganisms had no consistent effect on microbial zeta potential. Interestingly, adherence of the three, saliva-treated Candida spp. to saliva-treated silicone and PVC was significantly lower than whenever the microorganisms and biomaterials had been treated with PBS (p < 0.05). Treatment of silicone and PVC with saliva significantly altered the surface properties, notably reducing both the advancing and receding contact angles and, additionally, the microrugosity. These effects may contribute to the decreased adherence of saliva-treated microorganisms to these biomaterials. In conclusion, this study has demonstrated the effects of physiological conditions within the oral cavity on the adherence of selected Candida spp. to biomaterials employed as oropharyngeal medical devices. In particular, this study has ominously shown that these materials act as substrates for yeast colonization, highlighting the need for advancements in biomaterial design. Furthermore, it is important that physiological conditions should be employed whenever biocompatibility of oropharyngeal biomaterials is under investigation. © 2001 Kluwer Academic Publishers.
Resumo:
The paper outlines the effects of polymer conditioning on alum sludge properties, such as floc size, density, fractal dimension (DF) and rheological properties. Experimental results demonstrate that polymer conditioning of alum sludge leads to: larger floc size with a plateau reached in higher doses; higher densities associated with higher doses; increased degree of compactness; and an initial decrease followed by an increase of supernatant viscosity with continued increase in polymer dose. The secondary focus of this paper dwells on a comparison of the estimates of optimum dose using different criteria that emanate from established dewatering tests such as CST, SRF, liquid phase viscosity and modified SRF as well as a simple settlement test in terms of CML30. Alum sludge was derived from a water works treating coloured, low-turbidity raw waters.
Resumo:
Factors relating to identity and to economics have been shown to be important predictors of attitudes towards the European Union (EU). In this article, we show that the impact of identity is conditional on economic context. First, living in a member state that receives relatively high levels of EU funding acts as a 'buffer', diluting the impact of an exclusive national identity on Euroscepticism. Second, living in a relatively wealthy member state, with its associated attractiveness for economic migrants, increases the salience of economic xenophobia as a driver of sceptical attitudes. These results highlight the importance of seeing theories of attitude formation (such as economic and identity theories) not as competitors but rather as complementary, with the predictive strength of one theoretical approach (identity) being a function of system-level variation in factors relating to the other theoretical approach (macro-level economic conditions).
Resumo:
The coupled heat, air and moisture transfer between building envelopes and indoor air is complicated, and has a significant influence on the indoor environment and the energy performance of buildings. In the paper, a model for predicting coupled multi-zone hygrothermal-airflow transfer is presented. Both heat and moisture transfer in the building envelope and multi-zone indoor airflow are simultaneously considered; their interactions are modeled. The coupled system model is implemented into Matlab–Simulink, and is validated by using a series of testing tools and experiments. The new program is applied to investigate the moisture transfer effect on indoor air humidity and building energy consumption in different climates (hot-humid, temperate and hot-dry climates). The results show that not accounting for hygrothermal effects in modeling will result in overestimation of energy costs for hot and humid climate situations and possible over sizing of plant leading to inefficient operation.
Resumo:
A two-dimensional mathematical model for evaluating the simultaneous heat and moisture migration in porous building materials was proposed. Vapor content and temperature were chosen as the principal driving potentials. The numerical solution was based on the control volume finite difference technique with fully implicit scheme in time. Two validation experiments were developed in this study. The evolution of transient moisture distributions in both one-dimensional and two-dimensional cases was measured. A comparison between experimental results and those obtained by the numerical model proves that they are fully consistent with each other. The model can be easily integrated into a whole building heat, air and moisture transfer model. Another main advantage of the present numerical method lies in the fact that the required moisture transport properties are comparatively simple and easy to determine.