145 resultados para hip fracture

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Hip protectors are protective pads designed to cover the greater trochanter and attenuate or disperse the force of a fall sufficiently to prevent a hip fracture. Promising results from randomised controlled trials in nursing homes have resulted in hip protectors being widely recommended in the health care literature and in national guidelines. Objectives: The objectives of the study were to identify characteristics of individual residents, and the organisational features of the homes in which they live, which may affect adherence to wearing hip protectors. Design: An observational, correlation study designed to identify factors related to adherence. Setting: Forty nursing and residential homes in the UK. Participants: 1346 residents of the homes who were not confined to bed and with no pressure sore on the hip. Methods: The introduction of an evidence-based policy to offer Safehips hip protectors to residents free of charge and with support from a nurse facilitator. Adherence to wearing the hip protectors was observed over 72 weeks. Results: Initial acceptance of the hip protectors was 37.2%. Continued adherence was 23.9% at 24 weeks; 23.2% at 48 weeks; and 19.9% at 72 weeks. Greater adherence was associated with the following individual resident characteristics: a greater degree of dependency (95% CI 1.39 - m3.78) and cognitive impairment (95% CI 1.01 - 2.98); being male rather than female (95% CI 1.06 - 2.48). Greater adherence was also associated with the following organisational characteristics of homes: fewer changes of senior manager during the study period (95% CI 1.01 - 8.51), and being resident in a home with a resident profile showing a greater proportion of residents with a higher degree of dependency (95% CI 1.04 - 1.27). There was wide a variation in the degree of success in implementation between homes (adherence of 0 - 100% at 24 weeks). Conclusions: Those implementing a policy of introducing hip protectors into nursing and residential homes should consider targeting residents with cognitive impairment. Such residents are at greater risk of hip fracture and appear to be more likely to continue wearing hip protectors. Those charged with implementing changes inpractice or policy should consider how the context for implementation can be optimised to increase the likelihood of success.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: to evaluate the effectiveness of a policy of making hip protectors available to residents of nursing homes. Design: a cluster randomised controlled trial of the policy in nursing and residential homes, with the home as the unit of randomisation. Setting: 127 nursing and residential homes in the greater Belfast area of Northern Ireland. Participants: 40 homes in the intervention group (representing 1,366 occupied beds) and 87 homes in the control group (representing 2,751 occupied beds). Interventions: a policy of making hip protectors available free of charge to residents of nursing homes and supporting the implementation process by employing a nurse facilitator to encourage staff in the homes to promote their use, over a 72-week period. Main outcome measures: the rate of hip fractures in intervention and control homes, and the level of adherence to use of hip protectors. Results: there were 85 hip fractures in the intervention homes and 163 in the control homes. The mean fracture rate per 100 residents was 6.22 in the intervention homes and 5.92 in the control homes, giving an adjusted rate ratio for the intervention group compared to the control group of 1.05 (95% CI 0.77, 1.43, P = 0.76). Initial acceptance of the hip protectors was 37.2% (508/1,366) with adherence falling to 19.9% (272/1,366) at 72 weeks. Conclusions: making hip protectors available to residents of nursing and residential homes did not reduce the rate of hip fracture.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract:
Background: An estimated 30-60% of older
adults fall every year and about 1% of falls result in a hip fracture. Hip fracture is a serious and growing problem, with a 3-10 fold rise in worldwide incidence predicted by 2050 (Gullberg, et al 1997). Hip protectors are underwear with built in protection for the greater trochanter. They are designed to prevent hip fractures by dispersing or absorbing the force of a fall. Trials
published to 2001 were broadly supportive of
the effectiveness of hip protectors, and this
was reflected in a Cochrane review in 2000.
However, earlier trials were methodologically
flawed and subsequent trials have not demonstrated effectiveness. The most recent Cochrane review describes only a marginal benefit (Parker et al, 2005).
Review and Discussion: This presentation
evaluates the current evidence for the use
of hip protectors and discusses the use of
that evidence by manufacturers, suppliers,
professional groups and guideline developers.
Interestingly, despite the limitations of the
evidence base, most advice has been broadly
supportive. Reasons for this are proposed
and discussed in the context of a critique of
evidence-based healthcare. protectors. However, the available evidence can be used in different ways and for different purposes by those with an interest in promoting
the use of hip protectors. A conservative
approach is warranted, where, if we cannot
demonstrate that hip protectors work, we
presume that they do not. This presentation will be of use to practitioners wanting to evaluate the evidence base for hip protectors (and other recommended interventions) on behalf of clients. It will also be of interest to policy makers who must assess the claims made for health care technologies as part of the decisionmaking process.
Recommended reading:
Gullberg B, Johnell O, Kanis JA (1997) Worldwide
projections for hip fracture. Osteoporos
Int. 7(5):407-13 .
Parker MJ, Gillespie WJ, Gillespie LD (2005) Hip
protectors for preventing hip fractures in older
people. The Cochrane Database of Systematic
Reviews Issue 3. Art. No.: CD001255.pub3. DOI:
10.1002/14651858.CD001255.pub3.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Falls are a significant threat to the safety, health and independence of older citizens. Despite the substantial evidence that is available around effective falls prevention programmes and interventions, their translation into falls reduction programmes and policies has yet to be fully realised. While hip fracture rates are decreasing, the number and incidence of fall-related hospital admissions among older people continue to rise. Given the demographic trends that highlight increasing numbers of older people in the UK, which is broadly reflected internationally, there is a financial and social imperative to minimise the rate of falls and associated injuries. Falling is closely aligned to growing older (Slips, Trips and Falls Update: From Acute and Community Hospitals and Mental Health Units in England and Wales, Department of Health, HMSO, London, 2010). According to the World Health Organization, around 30% of older people aged over 65 and 50% of those over 80 will fall each year (Falls Fact Sheet Number 344, WHO, Geneva, 2010). Falls happen as a result of many reasons and can have harmful consequences, including loss of mobility and independence, confidence and in many cases even death (Cochrane Database Syst Rev 15, 2009, 146; Slips, Trips and Falls Update: From Acute and Community Hospitals and Mental Health Units in England and Wales, Department of Health, HMSO, London, 2010; Falling Standards, Broken Promises: Report of the National
Audit of Falls and Bone Health in Older People 2010, Health Care Quality
Improvement Partnership, London, 2011). What is neither fair nor correct is the
common belief by old and young alike that falls are just another inconvenience to put up with. The available evidence justifiably supports the view that well-organised services, based upon national standards and expert guidance, can prevent future falls among older people and reduce death and disability from fractures. This paper will draw from the UK, as an exemplar for policy and practice, to discuss the strategic direction of falls prevention programmes for older people and the partnerships that need to exist between researchers, service providers and users of services to translate evidence to the clinical setting. Second, it will propose some mechanisms for disseminating evidence to healthcare professionals and other stakeholders, to improve the quality and capacity of the clinical workforce.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to determine the fracture toughness of adhesive interfaces between dentine and clinically relevant, thin layers of dental luting cements. Cements tested included a conventional glass-ionomer, F (Fuji I), a resin-modified glass-ionomer, FP (Fuji Plus) and a compomer cement, D (DyractCem). Ten miniature short-bar chevron notch specimens were manufactured for each cement, each comprising a 40 µm thick chevron of lute, between two 1.5 mm thick blocks of bovine dentine, encased in resin composite. The interfacial KIC results (MN/m3/2) were median (range): F; 0.152 (0.14-0.16), FP; 0.306 (0.27-0.37), D; 0.351 (0.31-0.37). Non-parametric statistical analysis showed that the fracture toughness of F was significantly lower (p