43 resultados para heavy metal detection

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals, along with the potential use of novel taggants in environmental forensic investigations. The proposed system provides the facilities found in a traditional laboratory-based instrument but in a hand held design, without the need for an associated computer. The electrochemical instrument uses anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise a small disposable plastic strip of screen-printed electrodes rather than the more common glassy carbon disc and gold electrodes. The system is designed for use by a surveyor on site, allowing them to locate hotspots, thus avoiding the expense and time delay of prior laboratory analysis. This is particularly important in environmental forensic analysis when a site may have been released back to the owner and samples could be compromised on return visits. The system can be used in a variety of situations in environmental assessments, the data acquired from which provide a metals fingerprint suitable for input to a database. The proposed novel taggant tracers, based on narrow-band atomic fluorescence, are under development for potential deployment as forensic environmental tracers. The use of discrete fluorescent species in an environmentally stable host has been investigated to replace existing toxic, broadband molecular dye tracers. The narrow band emission signals offer the potential for tracing a large number of signals in the same environment. This will give increased data accuracy and allow multiple source environmental monitoring of environmental parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of anodic stripping voltammetry (ASV)has been proven in the past to be a precise and sensitive analytical method with an excellent limit of detection. Electrochemical sensors could help to avoid expensive and time consuming procedures as sample taking and storage and provide a both sensitive and reliable method for the direct monitoring of heavy metals in the aquatic environment. Solid electrodes which have been used in this work, were produced using previously developed methods. Commercially available and newly designed, screen printed carbon and gold plated working electrodes (WE) were compared. Good results were achieved with the screen printed and plated electrodes under conditions optimized for each electrode material. The electrode stability, reproducibility of single measurements and the limit of detection obtained for Pb were satisfactory (3*10-6mol/l on screen printed carbon WEs after 60 s of deposition and 6*10-6 mol/l on gold plated WEs after 5 min of deposition). Complete 3-electrode-sets (counter, reference and working electrode) were screen printed on different substrates (glass, polycarbonate and alumina). Also here, both carbon and gold were used as WE. Using 3-electrode-sets with a gold plated WE on glass was a limit of detection of 7*10-7 mol/l was achieved after only 60 s of deposition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a major review work on ground water remediation since the earlier work of Mulligan et al published in 2001 in Engineering Geology Journal. This work resulted from the joint research project of QUB and University of Malaya on iron removal from groundwater for public water supply.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The distribution coefficient, K-d, is often used to quantify heavy metal mobility in soils. Batch sorption or column infiltration tests may be used to measure K-d. The latter are closer to natural soil conditions, but are difficult to conduct in clays. This difficulty can be overcome by using a laboratory centrifuge. An acceleration of 2600 gravities was applied to columns of London Clay, an Eocene clay sub-stratum, and Cu, Ni, and Zn mobility was measured in centrifuge infiltration tests, both as single elements and in dual competition. Single-element K-d values were also obtained from batch sorption tests, and the results from the two techniques were compared. It was found that K-d values obtained by batch tests vary considerably depending on the metal concentration, while infiltration tests provided a single K-d value for each metal. This was typically in the lower end of the range of the batch test K-d values. For both tests, the order of mobility was Ni > Zn > Cu. Metals became more mobile in competition than when in single-element systems: Ni K-d decreased 3.3 times and Zn K-d 3.4 times when they competed with Cu, while Cu decreased only 1.2 times when in competition with either Ni or Zn. Our study showed that competitive sorption between metals increases the mobility of those metals less strongly bound more than it increases the mobility of more strongly bound metals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stoichiometrically equivalent concentrations of ethylenediaminetetraacetate, EDTA, and of related chelating anions increase the adsorption of ca. millimolar concentrations heavy metal aqua-ions on amorphous precipitates of aluminium(III) or iron(III) hydroxide and, although higher concentrations decrease the adsorption, poly-EDTA, a polyelectrolyte containing EDTA functional groups, shows no such decrease.