9 resultados para granule size
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
The flow patterns in a high shear granulator depend on the fill volume. For example, DEM simulations reported by Terashita et al. [1] show that fill volume affects the velocities and kinetic energies of the particles. It also influences the granule size distribution [2]. Here the effects on the properties of the granule are described. The total mass of the granulate material was varied without changing the other variables such as impeller speed, granulation time and liquid to solid ratio. The resulting mechanical properties, such as strength, yield stress and Young's modulus, of the granules were measured. For the materials studied in the current work, increasing the fill factor (batch size) increased the values of these material parameters. This could be explained by the relative increase in the number and intensity of collisions between the particles, when the size of a batch was increased, leading to smaller porosities. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
This study investigates the influence of process parameters on the fluidised hot melt granulation of lactose and PEG 6000, and the subsequent tablet pressing of the granules. Granulation experiments were performed to assess the effect of granulation time and binder content of the feed on the resulting granule properties such as mass mean granule size, size distribution, granule fracture stress, and granule porosity. These data were correlated using the granule growth regime model. It was found that the dominant granule growth mechanisms in this melt granulation system were nucleation followed by steady growth (PEG 10–20% w/w). However, with binder contents greater than 20% w/w, the granulation mechanism moved to the “over-wet massing” regime in which discrete granule formation could not be obtained. The granules produced in the melt fluidised bed process were subsequently pressed into tablets using an industrial tablet press. The physical properties of the tablets: fracture stress, disintegration time and friability were assessed using industry standards. These analyses indicated that particle size and binder content of the initial granules influenced the mechanical properties of the tablets. It was noted that a decrease in initial granule size resulted in an increase in the fracture stress of the tablets formed.
Resumo:
Previous work by the authors Walker et al. [2007b. Fluidised bed characterisation using Raman spectroscopy: applications to pharmaceutical processing. Chemical Engineering Science 62, 3832–3838] illustrated that Raman spectroscopy could be used to provide 3-D maps of the concentration and chemical structure of particles in motion in a fluidised bed, within a relatively short (120 s) time window. Moreover, we reported that the technique, as outlined, has the potential to give detailed in-situ information on how the structure and composition of granules/powders within the fluidised bed (dryer or granulator) vary with the position and evolve with time. In this study we extended the original work by shortening the time window of the Raman spectroscopic analysis to 10 s, which has allowed the in-situ real-time characterisation of a fluidised bed granulation process. Here we show an important new use of the technique which allows in-situ measurement of the composition of the material within the fluidised bed in three spatial dimensions and as a function of time. This is achieved by recording Raman spectra using a probe positioned within the fluidised bed on a long-travel x–y–z stage. In these experiments the absolute Raman intensity is used to provide a direct measure of the amount of any given material in the probed volume, i.e. a particle density. Particle density profiles have been calculated over the granulation time and show how the volume of the fluidised bed decreases with an increase mean granule size. The Raman spectroscopy analysis indicated that nucleation/coalescence in this co-melt fluidised hot melt granulation system occurred over a relatively short time frame (t<30 s). The Raman spectroscopic technique demonstrated accurate correlation with independent granulation experiments which provided particle size distribution analysis. The similarity of the data indicates that the Raman spectra accurately represent solids ratios within the bed, and thus the techniques quantitative capabilities for future use in the pharmaceutical industry.
Resumo:
Fluidised hot melt granulation (FHMG) is a novel technology for granulation process in pharmaceutical industry, which has distinct advantages over other commercial techniques. The aim of this research was to investigate granulation and the effect of process parameters that may affect FHMG process. In this work, ballotini beads were used as the model particles and Lutrol (R) F 68 Poloxamer 188 was used as meltable solid binder. In order to determine the granulation and nucleation mechanism in this co-melt FHMG system, several parameters were investigated, such as binder content, particle size of binder and particle size and hydrophobicity of ballotini. These parameters were correlated to granule size distribution, mean granule size and granule shape. Furthermore, these experimental investigations were designed so that the coalescence model could be applied to the co-melt FHMG system. The analysis indicated that the non-inertial regime extends over a relatively short time period of
Resumo:
Impeller speed is one of the most crucial process variables that affect the properties of the granules produced in a high-shear granulator. Several reports can be found in literature that discuss the influence of impeller speed on the granules size. For instance some researchers like Knight report an increase of granule size with impeller speed [1] and [2], while others (Scheaefer et al. and Ramaker et al.) observed a decrease of granules size with increasing impeller speed [3] and [4]. However there is limited work reported in literature on the effect of the impeller speed on the mechanical properties of granules. Mechanical properties are important as they affect the performance of the granules on the other downstream process such as transportation and handling. The work reported here serves to address the missing in knowledge gap regarding the influence of impeller speed on mechanical properties granules. How the granulation system responds to the changes in the impeller speeds depends on binder that is used in the process. For this reason the two extreme cases, of a low viscosity binder system and high viscosity binder system are considered in this research. For low viscosity binder system it was observed that the granule size decreased with increasing impeller speed whilst for the high viscosity binder system the opposite was observed by Knight [1]. The granule strength, the Young's modulus and yield strength of the high viscosity granules increased with increasing impeller speed where as the opposite trends were observed for the low viscosity binder granules.
Resumo:
Cultured cerebellar granule neurons (CGN) are commonly used to assess neurotoxicity, but are routinely maintained in supraphysiological (25 mM) extracellular K+ concentrations [K+]o. We investigated the effect of potassium channel blockade on survival of CGN derived from Swiss-Webster mice in supraphysiological (25 mM) and physiological (5.6 mM) [K+]o. CGN were cultured for 5 days in 25 mM K+, then in 5.6 mM K+ or 25 mM K+ (control). Viability, assayed 24 h later by 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) reduction and by lactate dehydrogenase (LDH) release, was ∼50% in 5.6 mM K+ versus 25 mM K+ (p < .001). Potassium channel blockers, 2 mM 4-aminopyridine (4-AP), 2 mM tetraethylammonium (TEA) or 1 mM Ba2+, individually afforded limited protection in 5.6 mM K+. However, survival in 5.6 mM K+ with a combination of 4-AP, TEA and Ba2+ was similar to survival in 25 mM K+ without blockers (p < .001 versus 5.6 mM K+ alone). CGN survival in 25 mM K+ was attenuated 25% by 2 μM nifedipine (p > .001), but nifedipine did not attenuate neuroprotection by K+ channel blockers. Together, these results suggest that the survival of CGN depends on the K+ permeability of the membrane rather than the activity of a particular type of K+ channel, and that the mechanism of neuroprotection by K+ channel blockers is different from that of elevated [K+]o.
Resumo:
The granular product being designed in this work required the use of two different powders namely limestone and teawaste; these materials have different bulk and particle densities. The overall aim of the project was to obtain a granular product in the size range of 2 to 4. mm. The two powders were granulated in different proportions using carboxymethylcellulose (CMC) as the binder. The effect of amount of binder added, relative composition of the powder, and type of teawaste on the product yield was studied. The results show that the optimum product yield was a function of both relative powder composition and the amount of binder used; increasing the composition of teawaste in the powder increased the amount of binder required for successful granulation. An increase in the mass fraction of teawaste in the powder mix must be accompanied by an increase in the amount of binder to maintain the desired product yield.
Resumo:
The overall aim of the project was to study the influence of process variables on the distribution of a model active pharmaceutical ingredient (API) during fluidised melt granulation of pharmaceutical granules with a view of optimising product characteristics. Granules were produced using common pharmaceutical excipients; lactose monohydrate using poly ethylene glycol (PEG1500) as a meltable binder. Methylene blue was used as a model API. Empirical models relating the process variables to the granules properties such as granule mean size, product homogeneity and granule strength were developed using the design of experiment approach. Fluidising air velocity and fluidising air temperature were shown to strongly influence the product properties. Optimisation studies showed that strong granules with homogeneous distribution of the active ingredient can be produced at high fluidising air velocity and at high fluidising air temperatures.
Resumo:
Small mixer impeller design is not tailored for granulation because impellers are intended for a wide range of processes. The aim of this research was to evaluate the performances of several impellers to provide guidance on the selection and design for the purposes of granulation. Lactose granules were produced using wet granulation with water as a binder. A Kenwood KM070 mixer was used as a standard apparatus and five impeller designs with different shapes and surface areas were used. The efficacy of granulate formation was measured by adding an optically sensitive tracer to determine variations in active ingredient content across random samples of granules from the same size classes. It was found that impeller design influenced the homogeneity of the granules and therefore can affect final product performance. The variation in active ingredient content across granules of differing size was also investigated. The results show that small granules were more potent than larger granules.