137 resultados para filling technique
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Objectives: To evaluate the placement of composite materials by new graduates using three alternative placement techniques.Methods: A cohort of 34 recently qualified graduates were asked to restore class II interproximal cavities in plastic teeth using three different techniques.
(i) A conventional incremental filling technique (Herculite XRV) using increments no larger than 2-mm with an initial layer on the cervical floor of the box of 1-mm.
(ii) Flowable bulk fill technique (Dentsply SDR) bulk fill placement in a 3-mm layer followed by an incremental fill of a microhybrid resin
(iii) Bulk fill (Kerr Sonicfill) which involved restorations placed in a 5-mm layer.
The operators were instructed in each technique, didactically and with a hands-on demonstration, prior to restoration placement.
All restorations were cured according to manufacturer’s recommendations. Each participant restored 3 teeth, 1 tooth per treatment technique.
The restorations were evaluated using modified USPHS criteria to assess both the marginal adaptation and the surface texture of the restorations. Blind evaluations were carried out independently by two examiners with the aid of magnification (loupes X2.5). Examiners were standardized prior to evaluation.
Results: Gaps between the tooth margins and the restoration or between the layers of the restoration were found in 13 of Group (i), 3 of Group (ii), and 4 of Group (iii)
Statistical analysis revealed a significant difference between the incrementally filled group (i) and the flowable bulk-fill group (ii) (p=0.0043) and between the incrementally filled (i) and the bulk fill groups (iii) (p=0.012) and no statistical difference (p=0.69) between the bulk filled groups Conclusions: Bulk fill techniques may result in a more satisfactory seal of the cavity margins when restoring with composite.
Resumo:
Purpose: The goal of this project was to see if using IMRT to deliver elective pelvic nodal irradiation (EPNI) for prostate cancer reduced acute treatment toxicity.
Methods: Two hundred and thirty patients were enrolled into prospective trials delivering EPNI with a concomitant hypofractionated IMRT boost to the prostate. During accrual, the method of EPNI delivery changed as new literature emerged. Three methods were used (1) 4FB, (2) IMRT with 2 cm CTV margins around the pelvic vessels as suggested by Shih et al. (2005) [7] (IMRT-Shih), and (3) IMRT with nodal volumes suggested by the RTOG (IMRT-RTOG). Initially patients were treated with an empty bladder, with the remainder treated with bladder full.
Results: Patients in the 4FB group had higher rates of grade 2 acute GI toxicities compared to the IMRT-Shih and IMRT-RTOG groups (31.9% vs 20.8% vs 7.2%, p = 0.0009). Patients in the 4FB group had higher rates of grade 3 urinary frequency compared to the two IMRT groups (8.5% vs 0% vs 0%, p = 0.027). However, multivariate analysis suggested the factor that most influenced toxicity was bladder filling followed by IMRT.
Conclusions: Bladder filling appeared to be the dominant factor which predicted for acute toxicity, followed by the use of IMRT.
Resumo:
This article describes the development of the first ion pair solid phase extraction technique (IPSPE), which has been applied to the extraction of metformin from plasma samples. In addition an ion pair chromatographic method was developed for the specific HPLC determination of metformin. Several extraction and HPLC methods have been described previously for metformin, however, most of them did not solve the problems associated with the high polarity of this drug. Drug recovery in the developed method was found to be more than 98%. The limit of detection and limit of quantification was 3 and 5 ng/ml, respectively. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error, R.E.%) was always less than 6.9%. Stability analysis showed that metformin is stable for at least 3 months when stored at -70degreesC. The method has been applied to 150 patient samples as part of a medication adherence study. (C) 2003 Elsevier B.V. All rights reserved.
Correlation of simulated and measured noise emissions using a combined 1D/3D computational technique
The Fatigue Life of Bone Cement: how it is affected by mixer design, vacuum level and user technique
Resumo:
This paper presents a study of the residual strength of Pinus sylvestris, which has been subject to attack by the furniture beetle (Anobium punctatum). It is relatively easy to stop the infestation, but difficult to assess the structural soundness of the remaining timber. Removal and replacement of affected structural elements is usually difficult and expensive, particularly in buildings of historic interest. Current on-site assessment procedures are limited. The main object of the study was to develop an on-site test of timber quality: a test which can be carried out on the surface and also at varying depths into the timber. It is based on a probe pull-out technique using a portable load-measuring device. Pull-out force values have been correlated with both strength and energy absorbed as measured by compression testing on laboratory samples of both sound and infested timber. These two relationships are significant and could be used to assess whether remedial work is needed. In addition, work on the use of artificial borings to simulate the natural worming of timber is presented and the findings discussed.