34 resultados para experimental intensity parameter

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims. In this paper we report electron impact collision strengths and excitation rates for transitions among the lowest 89 levels of Ni XIX.
Methods. The Dirac atomic R-matrix code (DARC) is adopted for the calculations of collision strengths and subsequently the effective collision strengths.
Results. Collision strengths for resonance transitions among 89 levels arising from the (1s2) 2s22p6, 2s22p53$\ell$, 2s2p63$\ell$, 2s22p54$\ell$, and 2s2p64$\ell$ configurations of Ni XIX are reported over a wide energy range below 250 Ryd. Additionally, effective collision strengths for all 3916 transitions among the 89 levels are listed over a wide temperature range below 107 K. Comparisons are made among different calculations and the accuracy of the data is assessed. Finally, comparisons between theoretical and experimental intensity ratios of some prominent lines of Ni XIX are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Understanding the microscopic mechanisms of electronic excitation in organic photovoltaic cells is a challenging problem in the design of efficient devices capable of performing sunlight harvesting. Here we develop and apply an ab initio approach based on time-dependent density functional theory and Ehrenfest dynamics to investigate photoinduced charge transfer in small organic molecules. Our calculations include mixed quantum–classical dynamics with ions moving classically and electrons quantum mechanically, where no experimental external parameter other than the material geometry is required. We show that the behavior of photocarriers in zinc phthalocyanine (ZnPc) and C60 systems, an effective prototype system for organic solar cells, is sensitive to the atomic orientation of the donor and the acceptor units as well as the functionalization of covalent molecules at the interface. In particular, configurations with the ZnPc molecules facing on C60 facilitate charge transfer between substrate and molecules that occurs within 200 fs. In contrast, configurations where ZnPc is tilted above C60 present extremely low carrier injection efficiency even at longer times as an effect of the larger interfacial potential level offset and higher energetic barrier between the donor and acceptor molecules. An enhancement of charge injection into C60 at shorter times is observed as binding groups connect ZnPc and C60 in a dyad system. Our results demonstrate a promising way of designing and controlling photoinduced charge transfer on the atomic level in organic devices that would lead to efficient carrier separation and maximize device performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report an experimental technique for the comparison of ionization processes in ultrafast laser pulses irrespective of pulse ellipticity. Multiple ionization of xenon by 50 fs 790 nm, linearly and circularly polarized laser pulses is observed over the intensity range 10 TW/cm(2) to 10 PW/cm(2) using effective intensity matching (EIM), which is coupled with intensity selective scanning (ISS) to recover the geometry-independent probability of ionization. Such measurements, made possible by quantifying diffraction effects in the laser focus, are compared directly to theoretical predictions of multiphoton, tunnel and field ionization, and a remarkable agreement demonstrated. EIM-ISS allows the straightforward quantification of the probability of recollision ionization in a linearly polarized laser pulse. Furthermore, the probability of ionization is discussed in terms of the Keldysh adiabaticity parameter gamma, and the influence of the precursor ionic states present in recollision ionization is observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Double slits have been incorporated in a flat field spectrometer to record spatially resolved and integrated spectra simultaneously. Variation of the absorbed irradiance and ionisation stage along the fibre plasmas has been monitored. By comparison of the spatially resolved and integrated resonance line ratios, it is found that the spatially integrated values deviated significantly from the real experimental circumstances due to nonuniformity along the plasmas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Because unemployment benefit reforms tend to package together changes to job search requirements, monitoring and assistance, few existing studies have been able to empirically isolate the effects of job search monitoring intensity on the behaviour of unemployment benefit claimants. This paper exploits periods where monitoring has been temporarily withdrawn during a series of Benefit Office refurbishments - with the regime otherwise unchanged - to allow such identification. During these periods of zero monitoring the hazard rates for exits from claimant unemployment and for job entry both fall. © 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent R-matrix calculations of electron impact excitation rates in Ni XII are used to derive the emission line ratios R-1 = I(154.17 Angstrom)/I(152.15 Angstrom), R-2 = I(152.95 Angstrom)/I(152.15 Angstrom) and R-3 = 1(160.55 Angstrom)/I(152.15 Angstrom). This is the first time (to our knowledge) that theoretical emission line ratios have been calculated for this ion. The ratios are found to be insensitive to changes in the adopted electron density (N-e) when N-e greater than or equal to 5 x 10(11) cm(-3), typical of laboratory plasmas. However, they do vary with electron temperature (T-e), with for example R-1 and R-3 changing by factors of 1.3 and 1.8, respectively, between T-e = 10(5) and 10(6) K. A comparison of the theoretical line ratios with measurements from the Joint European Tents (JET) tokamak reveals very good agreement between theory and observation for R-1, with an average discrepancy of only 7%. Agreement between the calculated and experimental ratios for R-2 and R-3 is less satisfactory, with average differences of 30 and 33%, respectively. These probably arise from errors in the JET instrument calibration curve. However, the discrepancies are smaller than the uncertainties in the R-2 and R-3 measurements. Our results, in particular for R-1, provide experimental support for the accuracy of the Ni XIII line ratio calculations, and hence for the atomic data adopted in their derivation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental investigations of the late-time ion structures formed in the wake of an ultrashort, intense laser pulse propagating in a tenuous plasma have been performed using the proton imaging technique. The pattern found in the wake of the laser pulse shows unexpectedly regular modulations inside a long, finite width channel. On the basis of extensive particle in cell simulations of the plasma evolution in the wake of the pulse, we interpret this pattern as due to ion modulations developed during a two-stream instability excited by the return electric current generated by the wakefield.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe an experimental system designed for single-shot photoelectron spectroscopy on free atoms and molecules at the Free Electron Laser in Hamburg (FLASH at DESY). The combination of the extreme ultra-violet (EUV) Free Electron Laser and a temporally synchronized optical fs laser (Ti:Sapphire) enables a variety of two-color pump-probe experiments. The spectral, temporal and spatial characteristics of both the EUV FEL and the optical laser pulses, the experimental procedure to control their overlap as well as the performance of an electron spectrometer used to obtain single-shot photoelectron spectra are discussed. As an illustration of the capabilities of this set-up, some results on two-photon two-color ionization of rare gases are presented. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a recent experimental study, the beam intensity profile of the Vulcan petawatt laser beam was measured; it was found that only 20% of the energy was contained within the full width at half maximum of 6.9 mu m and 50% within 16 mu m, suggesting a long-tailed non-Gaussian transverse beam profile. A q-Gaussian distribution function was suggested therein to reproduce this behavior. The spatial beam profile dynamics of a q-Gaussian laser beam propagating in relativistic plasma is investigated in this article. A non-paraxial theory is employed, taking into account nonlinearity via the relativistic decrease of the plasma frequency. We have studied analytically and numerically the dynamics of a relativistically guided beam and its dependence on the q-parameter. Numerical simulation results are shown to trace the dependence of the focusing length on the q-Gaussian profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ion acceleration resulting from the interaction of ultra-high intensity (2 x 10(20) W/cm(2)) and ultra-high contrast (similar to 10(10)) laser pulses with 0.05-10 mu m thick Al foils at normal (0 degrees) and 35 degrees laser incidence is investigated. When decreasing the target thickness from 10 mu m down to 0.05 mu m, the accelerated ions become less divergent and the ion flux increases, particularly at normal (0 degrees) laser incidence on the target. A laser energy conversion into protons of,similar to 6.5% is estimated at 35 degrees laser incidence. Experimental results are in reasonable agreement with theoretical estimates and can be a benchmark for further theoretical and computational work. (C) 2011 American Institute of Physics. [doi:10.1063/1.3643133]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of ultrasound on the percutaneous absorption of three nicotinate esters was investigated in 10 healthy volunteers in a double-blind placebo controlled crossover clinical trial. Using a specially designed experimental protocol, the effect of continuous output ultrasound (at frequency 3.0 MHz and intensity 1.0 W/cm2 for 5 min) on the percutaneous absorption of methyl, ethyl, and hexyl nicotinates, from gel bases, was investigated. A placebo control, involving massage with each of the gels, without ultrasound for 5 min, was also incorporated. The pharmacodynamic parameter of vasodilation caused by the nicotinates was used to monitor the percutaneous absorption of the drugs. Laser Doppler velocimetry, a noninvasive optical technique, was used to measure vasodilation of the cutaneous vessels within the treatment site. Ultrasound treatment led to enhanced vasodilator response to the nicotinates, therefore indicating an enhancement of their percutaneous absorption. These agents may prove to be useful compounds in examination of the mechanism of action of phonophoresis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photoresonant excitation has been examined as a mechanism for enhancing the maximum gain achievable on a H-like recombination scheme. Modelling of the system, using the MED101/NIMP package, has shown that the photoresonant excitation of the 1s-3p (Ly(beta)) transition at 12.644 angstrom in a H-like fluorine plasma by a Be-like manganese transition at 12.643 angstrom offers the possibility of considerable gain enhancement on the 3d-2p Balmer alpha at 80.91 angstrom over the simple H-like system. Some experimental evidence for a transitory increase in intensity on the Balmer-alpha has been obtained for a fluorine-coated C-fiber system pumped by irradiating a manganese stripe in close proximity to the fiber.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As the state of the art for high power laser systems increases from terawatt to petawatt level and beyond, a crucial parameter for routinely monitoring high intensity performance is laser spot size on a solid target during an intense interaction in the tight focus regime ( 10(19) Wcm(-2) is demonstrated experimentally and shown to provide the basis for an effective focus diagnostic. Importantly, this technique is also shown to allow in-situ diagnosis of focal spot quality achieved after reflection from a double plasma mirror setup for very intense high contrast interactions (> 10(20) Wcm(-2)) an important application for the field of high laser contrast interaction science.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report spatially and temporally resolved measurements of self-generated multi-megagauss magnetic fields produced during ultrahigh intensity laser plasma interactions. Spatially resolved measurements of the magnetic fields show an asymmetry in the distribution of field with respect to the angle of laser incidence. Temporally resolved measurements of the self-generated third harmonic suggest that the strength of the magnetic field is proportional to the square root of laser intensity (i.e., the laser B-field) during the rise of the laser pulse. The experimental results are compared with numerical simulations using a particle-in-cell code which also shows clear asymmetry of the field profile and similar magnetic field growth rates and scalings.