121 resultados para effect of pressure on porosity

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

TOPIC:

To analyze the literature pertaining to the techniques used in combined cataract and glaucoma surgery, including the technique of cataract extraction, the timing of the surgery (staged procedure versus combined procedure), the anatomic location of the operation, and the use of antifibrosis agents.

CLINICAL RELEVANCE:

Cataract and glaucoma are both common conditions and are often present in the same patient. There is no agreement concerning the optimal surgical management of these disorders when they coexist.

METHODS/LITERATURE REVIEWED:

Electronic searches of English language articles published since 1964 were conducted in Pub MED and CENTRAL, the Cochrane Collaboration's database. These were augmented by a hand search of six ophthalmology journals and the reference lists of a sample of studies included in the literature review. Evidence grades (A, strong; B, moderate; C, weak; I, insufficient) were assigned to the evidence that involved a direct comparison of alternative techniques.

RESULTS:

The preponderance of evidence from the literature suggests a small (2-4 mmHg) benefit from the use of mitomycin-C (MMC), but not 5-fluorouracil (5-FU), in combined cataract and glaucoma surgery (evidence grade B). Two-site surgery provides slightly lower (1-3 mmHg) intraocular pressure (IOP) than one-site surgery (evidence grade C), and IOP is lowered more (1-3 mmHg) by phacoemulsification than by nuclear expression in combined procedures (evidence grade C). There is insufficient evidence to conclude either that staged or combined procedures give better results or that alternative glaucoma procedures are superior to trabeculectomy in combined procedures.

CONCLUSIONS:

In the literature on surgical techniques and adjuvants used in the management of coexisting cataract and glaucoma, the strongest evidence of efficacy exists for using MMC, separating the incisions for cataract and glaucoma surgery, and removing the nucleus by phacoemulsification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: We conducted a systematic review and meta-analysis of observational studies to evaluate the effect of oral statins on intraocular pressure (IOP) and the incidence and progression of glaucoma. Methods: This was a systematic review of the literature and meta-analysis. Searches of PubMed/Medline and Embase were conducted to include all types of studies. Gray literature abstracts were also considered for inclusion. Last search date was February 2016. Risk of bias was assessed using the Newcastle-Ottawa scale independently by two reviewers. Odds ratios (OR) or hazard ratios (HR) and 95% confidence intervals (CI) were extracted from each study. Pooled ORs for incidence of glaucoma were calculated using a random-effects model. Results: We identified seven cohort studies, three case–control studies, and one cross-sectional study with a total number of 583,615 participants. No randomized controlled trials were retrieved. Pooled ORs demonstrated a statistically significant association between short-term statin use (≤2 years) and reduced incidence of glaucoma (OR 0.96, 95%CI 0.94, 0.99). Pooled ORs of long-term statin use (>2 years) did not demonstrate statistically significant reduction in incidence of glaucoma (OR 0.70, 95%CI 0.46, 1.06). There was inconsistent evidence for the protective effect of statins against the progression of glaucoma, although there was no standard definition for progression across studies. There was no significant difference in IOP associated with statin use. Conclusions: Short-term statin use is associated with a reduced incidence of glaucoma. The effect of statins on glaucoma progression and IOP is uncertain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated, using the single-pass isolated perfused rat liver preparation, whether the centrilobular location of hepatic oxidative drug metabolism could be a contributing factor to the marked sensitivity of drug oxidation to hypoxia. Livers (N = 7) were each perfused for 130 min with 2 micrograms/mL (+)-propranolol, a drug metabolized almost entirely by oxidation in the rat. The direction of flow was reversed after 60 min, the order of flow direction being randomized. Normal oxygenation was used during the first 30 min of antegrade and of retrograde perfusion, but in the second 30 min perfusate was equilibrated with a N2/O2 mixture designed to reduce hepatic oxygen delivery by half. During normal oxygenation there was no significant difference between antegrade and retrograde perfusion in hepatic oxygen delivery and physiological parameters such as oxygen consumption and extraction, perfusion pressure and bile flow. During hypoxia, mean oxygen delivery was slightly lower with retrograde perfusion (retrograde: mean = 2.37 mumol/min/g liver, range = 1.56-3.17; antegrade: mean = 2.90 mumol/min/g liver, range = 1.96-4.08; P = 0.04), but there was no significant difference in physiological parameters within each liver (P > 0.05). Propranolol clearance during normal oxygenation was similar to the perfusion rate (10 mL/min) and was the same for both directions of perfusion (antegrade 9.88 +/- 0.07 mL/min, retrograde 9.88 +/- 0.13 mL/min, P > 0.05). Hypoxia reduced propranolol clearance substantially, but the decrease was significantly greater with antegrade perfusion (5.65 +/- 1.89 mL/min) than with retrograde perfusion (6.76 +/- 1.95 mL/min, P = 0.014). Oxidative drug metabolism is located primarily in the centrilobular zone and sinusoidal oxygen concentration is lowest in the "downstream" zone with both antegrade and retrograde perfusion. These findings suggest that the centrilobular location of propranolol metabolism may influence the effect of hypoxia on propranolol elimination, but is not a major contributor to the marked sensitivity of propranolol elimination to hypoxia antegrade perfusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The plain fatigue and fretting fatigue tests of Ti-1023 titanium alloy were performed using a high-frequency push-pull fatigue testing machine. Both σmax versus number of cycles to failure curves were obtained for comparative analysis of the fretting effect on fatigue performance of the titanium alloy. Meanwhile, by analyzing the fracture of plain fatigue and fretting fatigue, the fretting scar and the fretting debris observed by scanning electron microscopy (SEM), the mechanism of fretting fatigue failure of Ti-1023 titanium alloy is discussed. The fretting fatigue strength of Ti-1023 titanium alloy is 175 MPa under 10 MPa contact pressure, which is 21% of plain fatigue strength (836 MPa). Under fretting condition, the Ti-1023 titanium alloy fatigue fracture failure occurs in a shorter fatigue life. When it comes to σmax versus number of cycles to failure curves, data points in the range of 106–107 cycles under plain fatigue condition moved to the range of 105–106 under fretting fatigue condition. The integrity of the fatigue specimen surface was seriously damaged under the effect of fretting. With the alternating stress loaded on specimen, the stress concentrated on the surface of fretting area, which brought earlier the initiation and propagation of crack.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the results from investigations into the differences in the rotational moulding and mechanical properties between pigmented polyethylene powder and micropellets. Both high shear and low shear pigment blending methods were examined, as were a range of pigment addition levels. This was followed by a series of mechanical and analytical tests on the rotomoulded articles to determine properties. Whilst micropellets tended to produce a different surface porosity than powder, few bubbles were evident within the wall thickness for both high shear and low shear blending. For high shear blending, with pigment addition levels up to 0.05%, similar impact properties were noticed for both powder and micropellets. Low shear blending resulted in more inconsistent impact values. There were also more visual inconsistencies in articles produced from powder.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electron energy-loss near-edge structure (ELNES) at the oxygen K-edge has been investigated in a range of yttria-stabilized zirconia (YSZ) materials. The electronic structure of the three polymorphs of pure ZrO2 and of the doped YSZ structure close to the 33 mol %Y2O3 composition have been calculated using a full-potential linear muffin-tin orbital method (NFP-LMTO) as well as a pseudopotential based technique. Calculations of the ELNES dipole transition matrix elements in the framework of the NFP-LMTO scheme and inclusion of core hole screening within Slater's transition state theory enable the ELNES to be computed. Good agreement between the experimental and calculated ELNES is obtained for pure monoclinic ZrO2. The agreement is less good with the ideal tetragonal and cubic structures. This is because the inclusion of defects is essential in the calculation of the YSZ ELNES. If the model used contains ordered defects such as vacancies and metal Y planes, agreement between the calculated and experimental O K-edges is significantly improved. The calculations show how the five different O environments of Zr,Y,O, are connected with the features observed in the experimental spectra and demonstrate clearly the power of using ELNES to probe the stabilization mechanism in doped metal oxides.