24 resultados para componentwise ultimate bounds
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
The upper and lower bounds on the actual solution of any microwave structure is of general interest. The purpose of this letter is to compare some calculations using the mode-matching and finite-element methods, with some measurements on a 180 degrees ridge waveguide insert between standard WR62 rectangular waveguides. The work suggests that the MMM produces an upper bound, while the FEM places a lower bound on the measurement. (C) 2001 John Wiley & Sons, Inc.
Resumo:
In the investigation of real loading capacities in concrete bridge deck slabs,the study of this type of structure was carried out with consideration of compressive membrane action.A series of experimental test of steel-concrete bridge structures was developed with the analysis of influences from the varying of structural parameters on loading capacities,including reinforcement percentages,supporting beam sizes and concrete compressive strength.Through the study of the experimental results,it was found that the real structural loading capacities are larger than those predicted by current design methods.Therefore,based on the previous research,a prediction method for loading capacities of concrete bridge deck slabs was established with consideration of CMA,which was built based on the plastic ultimate analysis.In this method,the lateral restraint stiffness subjected by concrete bridge deck slabs was provided.The proposed theoretical model is capable of predicting the loading capacities of this type of structure accurately with comparison of results from several bridge deck experimental tests.
Resumo:
In the last 50 years, many bridges have been built as composite structures with decks of reinforced concrete that are supported by longitudinal steel beams. The presence of the longitudinal steel beams and the unloaded area of concrete slab cause the loaded deck slabs to be restrained against lateral expansion. As a result, a compressive membrane thrust is developed. In experimental tests, the authors built a series of one-third scale steel-concrete composite bridge models with several varying structural parameters, including concrete compressive strength, reinforcement percentage, and the size of steel supporting beams. After comparing the results of different models, the influence of these structural parameters on the amount of compressive membrane action in the deck slab was evaluated. Furthermore, the improvement of an existing theoretical model provided accurate predictions for the loading-carrying capacities.
Resumo:
This paper presents design recommendations for the strength of cold-formed steel angle structs. The work was part funded by the Carnegie Trust and is co-authored by academics from Hong-Kong University. The work has led to a collaboration with the University of Malaya, attempting to predict the strength using artificial neural networks.
Resumo:
The behaviour and design of bolted moment-connections between cold-formed steel members, formed by using brackets bolted to the webs of the section, is considered. The particular problem of the moment-capacity of such joints being lower than that of the cold-formed steel sections being connected because of web buckling, caused by the concentration of load transfer from the bolts, is addressed. In this paper, a combination of laboratory tests and finite element analyses is used to investigate this mode of failure. It is demonstrated that there is good agreement between the measured ultimate moment-capacity and that predicted by using the finite element method. A parametric study conducted using the finite element model shows that the moment-capacity of a practical size joint can be up to 20% lower than that of the cold-formed steel sections being connected. Web buckling so-caused must therefore be considered in the design of such connections. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
The finite element method in conjunction with the Soutis-Fleck model is used to predict the residual strength after impact of a carbon-fibre reinforced plastic wingbox subjected to a cantilever type loading. The maximum stress failure criterion further validates the Soutis-Fleck model predictions. The Soutis-Fleck model predicts that the wingbox fails at a tip load of 99.2 kN, approximately 5.5% less than the experimental observation