104 resultados para biologic removal

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the possible biotechnological application of the phenomenon of low pH-inducible phosphate uptake and polyphosphate accumulation, previously reported using pure microbial cultures and under laboratory conditions, a 2000 L activated sludge pilot plant was constructed at a municipal sewage treatment works. When operated as a single-stage reactor this removed more than 60% of influent phosphate from primary settled sewage at a pH of 6.0, as opposed to approximately 30% at the typical operational pH for the works of 7.0-7.3-yet without any deleterious effect on other treatment parameters. At these pH values the phosphorus content of the sludge was, respectively, 4.2% and 2.0%. At pH 6.0 some 33.9% of sludge microbial cells were observed to contain polyphosphate inclusions; the corresponding value at pH 7.0 was 18.7%. Such a process may serve as a prototype for the development of alternative biological and chemical options for phosphate removal from wastewaters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic resins are shown to be effective in removing uranium from contaminated groundwater. Batch and field column tests showed that strong-base anion-exchange resins were more effective in removing uranium from both near-neutral-pH (6.5)- and high-pH (8)-low-nitrate-containing groundwaters, than metal-chelating resins, which removed more uranium from acidic-pH (5)-high-nitrate-containing groundwater from the Oak Ridge Reservation (ORR) Y-12 S-3 Ponds area in Tennessee, USA. Dowex 1-X8 and Purolite A-520E anion-exchange resins removed more uranium from high-pH (8)-low-nitrate-containing synthetic groundwater in batch tests than metal-chelating resins. The Dowex™ 21K anion-exchange resin achieved a cumulative loading capacity of 49.8 mg g-1 before breakthrough in a field column test using near-neutral-pH (6.5)-low-nitrate-containing groundwater. However, in an acidic-pH (5)-high-nitrate-containing groundwater, metal-chelating resins Diphonix and Chelex-100 removed more uranium than anion-exchange resins. In 15 mL of acidic-pH (5)-high-nitrate-containing groundwater spiked with 20 mg L-1 uranium, the uranium concentrations ranged from 0.95 mg L-1 at 1-h equilibrium to 0.08 mg L-1 at 24-h equilibrium for Diphonix and 0.17 mg L-1 at 1-h equilibrium to 0.03 mg L-1 at 24-h equilibrium for Chelex-100. Chelex-100 removed more uranium in the first 10 min in the 100 mL of acidic-(pH 5)-high-nitrate-containing groundwater (~5 mg L-1 uranium); however, after 10 min, Diphonix equaled or out-performed Chelex-100. This study presents an improved understanding of the selectivity and sorption kenetics of a range of ion-exchange resins that remove uranium from both low- and high-nitrate-containing groundwaters with varying pHs..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The removal of false coincidences from measurements of coincidences between two photoelectrons and one or two ions formed in molecular double photoionization is described. False coincidences arise by several mechanisms; experimental procedures and mathematical formulae required to remove all the different false coincidence contributions are described. Sample spectra taken of the double photoionization of carbon dioxide are presented to illustrate the method of false coincidence subtraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with removal of Cesium (radioactive waste) in dilute aqueous phase by adsorption. Fullers earth was used as an adsorbent. The adsorption capacity of Fullers earth with respect to Cesium was found to be high, 26.3 mg / g of adsorbent.