9 resultados para beam quality
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
The emission characteristics of intense laser driven protons are controlled using ultrastrong (of the order of 10(9) V/m) electrostatic fields varying on a few ps time scale. The field structures are achieved by exploiting the high potential of the target (reaching multi-MV during the laser interaction). Suitably shaped targets result in a reduction in the proton beam divergence, and hence an increase in proton flux while preserving the high beam quality. The peak focusing power and its temporal variation are shown to depend on the target characteristics, allowing for the collimation of the inherently highly divergent beam and the design of achromatic electrostatic lenses.
Resumo:
Delivering sufficient dose to tumours while sparing surrounding tissue is one of the primary challenges of radiotherapy, and in common practice this is typically achieved by using highly penetrating MV photon beams and spatially shaping dose. However, there has been a recent increase in interest in the possibility of using contrast agents with high atomic number to enhance the dose deposited in tumours when used in conjunction with kV x-rays, which see a significant increase in absorption due to the heavy element's high-photoelectric cross-section at such energies. Unfortunately, the introduction of such contrast agents significantly complicates the comparison of different source types for treatment efficacy, as the dose deposited now depends very strongly on the exact composition of the spectrum, making traditional metrics such as beam quality less valuable. To address this, a 'figure of merit' is proposed, which yields a value which enables the direct comparison of different source types for tumours at different depths inside a patient. This figure of merit is evaluated for a 15 MV LINAC source and two 150 kVp sources (both of which make use of a tungsten target, one with conventional aluminium filtration, while the other uses a more aggressive thorium filter) through analytical methods as well as numerical models, considering tissue treated with a realistic concentration and uptake ratio of gold nanoparticle contrast agents (10 mg ml(-1) concentration in 'tumour' volume, 10: 1 uptake ratio). Finally, a test case of human neck phantom is considered with a similar contrast agent to compare the abstract figure to a more realistic treatment situation. Good agreement was found both between the different approaches to calculate the figure of merit, and between the figure of merit and the effectiveness in a more realistic patient scenario. Together, these observations suggest that there is the potential for contrast-enhanced kilovoltage radiation to be a useful therapeutic tool for a number of classes of tumour on dosimetric considerations alone, and they point to the need for further research in this area.
Resumo:
Metrology of XUV beams (X-ray lasers, high-harmonic generation and VUV free-electron lasers) is of crucial importance for the development of applications. We have thus developed several new optical systems enabling us to measure the optical properties of XUV beams. By use of a Michelson interferometer working as a Fourier-transform spectrometer, the line shapes of different X-ray lasers have been measured with a very high accuracy (Deltalambda/lambdasimilar to10(-6)). Achievement of the first XUV wavefront sensor has enabled us to measure the beam quality of laser-pumped as well as discharge-pumped X-ray lasers. A capillary discharge X-ray laser has demonstrated a very good wavefront allowing us to achieve an intensity as high as 3x10(14) W cm(-2) by focusing with a f=5 cm mirror. The sensor accuracy has been measured using a calibrated spherical wave generated by diffraction. The accuracy has been estimated to be as good as lambda/120 at 13 nm. Commercial developments are underway. At Laboratoire d'Optique Appliquee, we are setting up a new beamline based on high-harmonic generation in order to start the femtosecond, coherent XUV optic .
Resumo:
Recently, the use of plasma optics to improve temporal pulse contrast has had a remarkable impact on the field of high- power laser-solid density interaction physics. Opening an avenue to previously unachievable plasma density gradients in the high intensity focus, this advance has enabled researchers to investigate new regimes of harmonic generation and ion acceleration. Until now, however, plasma optics for fundamental laser reflection have been used in the sub-relativistic intensity regime (10(15) - 10(16)Wcm(-2)) showing high reflectivity (similar to 70%) and good focusability. Therefore, the question remains as to whether plasma optics can be used for such applications in the relativistic intensity regime (> 10(18)Wcm(-2)). Previous studies of plasma mirrors (PMs) indicate that, for 40 fs laser pulses, the reflectivity fluctuates by an order of magnitude and that focusability of the beam is lost as the intensity is increased above 5 x 10(16)Wcm(-2). However, these experiments were performed using laser pulses with a contrast ratio of similar to 10(7) to generate the reflecting surface. Here, we present results for PM operation using high contrast laser pulses resulting in a new regime of operation - the high contrast plasma mirror (HCPM). In this regime, pulses with contrast ratio > 10(10) are used to form the PM surface at > 10(19)Wcm(-2), displaying excellent spatial filtering, reflected near- field beam profile of the fundamental beam and reflectivities of 60 +/- 5%. Efficient second harmonic generation is also observed with exceptional beam quality suggesting that this may be a route to achieving the highest focusable harmonic intensities. Plasma optics therefore offer the opportunity to manipulate ultra-intense laser beams both spatially and temporally. They also allow for ultrafast frequency up-shifting without detrimental effects due to group velocity dispersion (GVD) or reduced focusability which frequently occur when nonlinear crystals are used for frequency conversion.
Visual functioning and quality of life in the subfoveal radiotherapy study (SFRADS): SFRADS report 2
Resumo:
Aims: To determine whether or not self reported visual functioning and quality of life in patients with choroidal neovascularisation caused by age related macular degeneration (AMD) is better in those treated with 12 Gy external beam radiotherapy in comparison with untreated subjects. Methods: A multicentre single masked randomised controlled trial of 12 Gy of external beam radiation therapy (EBRT) delivered as 6x2 Gy fractions to the macula of an affected eye versus observation. Patients with AMD, aged 60 years or over, in three UK hospital units, who had subfoveal CNV and a visual acuity equal to or better than 6/60 (logMAR 1.0). Methods: Data from 199 eligible participants who were randomly assigned to 12 Gy teletherapy or observation were available for analysis. Visual function assessment, ophthalmic examination, and fundus fluorescein angiography were undertaken at baseline and at 3, 6, 12, and 24 months after study entry. To assess patient centred outcomes, subjects were asked to complete the Daily Living Tasks Dependent on Vision (DLTV) and the SF-36 questionnaires at baseline, 6, 12, and 24 months after enrolment to the study. Cross sectional and longitudinal analyses were conducted using arm of study as grouping variable. Regression analysis was employed to adjust for the effect of baseline co-variates on outcome at 12 months and 24 months. Results: Both control and treated subjects had significant losses in visual functioning as seen by a progressive decline in mean scores in the four dimensions of the DLTV. There were no statistically significant differences between treatment and control subjects in any of dimensions of the DLTV at 12 months or 24 months after study entry. Regression analysis confirmed that treatment status had no effect on the change in DLTV dimensional scores. Conclusions: The small benefits noted in clinical measures of vision in treated eyes did not translate into better self reported visual functioning in patients who received treatment when compared with the control arm. These findings have implications for the design of future clinical trials and studies.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
PURPOSE: Men are living longer with prostate cancer. In a two-country study, we investigated the health-related quality of life (HRQoL) of prostate cancer survivors up to 18 years post-diagnosis.
METHODS: Postal questionnaires were administered in 2012 to 6559 prostate cancer (ICD10 C61) survivors 2-18 years post-diagnosis, identified through population-based cancer registries in Ireland. HRQoL was measured using QLQ-C30 and QLQ-PR25. HRQoL, functional and symptom scores were compared by primary treatment(s) using multiple linear regression.
RESULTS: Fifty-four percent responded (n = 3348). After controlling for socio-demographic and clinical factors, global HRQoL varied significantly by primary treatment (p < 0.001); compared to radical prostatectomy (RP), survivors who received androgen deprivation therapy alone (ADT; p < 0.001) or external beam radiotherapy (EBRT) without concurrent ADT (p = 0.001) had significantly lower global HRQoL. The global HRQoL of men who received brachytherapy (p = 0.157), EBRT with concurrent ADT (p = 0.940) or active surveillance/watchful waiting (p = 0.388) was not significantly different from men treated with RP. There were statistically and clinically significant differences in general (fatigue, pain, dyspnoea, appetite loss, constipation, diarrhoea, financial difficulties) and disease-specific symptoms (sexual, urinary, bowel, ADT) by primary treatment. Fatigue and insomnia scores were high for survivors in all treatment groups.
CONCLUSIONS: Prostate cancer survivors' long-term HRQoL varied with primary treatment.
IMPLICATIONS OF CANCER SURVIVORS: Population-based information regarding statistically and clinically significant treatment effects on long-term global HRQoL, symptom burden and functionality should be provided during treatment decision-making. Screening for symptoms and utilising interventions during long-term follow-up may improve survivors' HRQoL.
Resumo:
An ultra-relativistic electron beam propagating through a high-Z solid triggersan electromagnetic cascade, whereby a large number of high-energy photons andelectron–positron pairs are produced mainly via the bremsstrahlung and Bethe–Heitler processes, respectively. These mechanisms are routinely used to generatepositron beams in conventional accelerators such as the electron–positron collider(LEP). Here we show that the application of similar physical mechanisms to a laserdrivenelectron source allows for the generation of high-quality positron beams in amuch more compact and cheaper configuration. We anticipate that the applicationof these results to the next generation of lasers might open the pathway for therealization of an all-optical high-energy electron–positron collider.