12 resultados para astigmatism
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Purpose: To assess the demographics and distribution of corneal astigmatism before cataract surgery in Chinese patients. Setting: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Clinic-based cross-sectional study. Methods: From July 2009 to May 2011, preoperative bilateral partial coherence interferometry (IOLMaster) was performed in consecutive patients having cataract surgery. Patient demographics and keratometric data were recorded. Results: The mean age of the 2849 patients (4831 eyes) was 70.56 years ± 9.55 (SD); there was a predominance of women patients (64.0%). The mean axial length was 23.58 ± 1.13 mm. The mean corneal astigmatism in this cohort was 1.01 D (range 0.05 to 6.59 D). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 25.1% of eyes, against the rule (ATR) in 58.2% of eyes, and oblique in 16.7% of eyes. The mean steep keratometry measurement was 44.76 ± 1.56 D. Against-the-rule astigmatism increased significantly with older age. Conclusions: Corneal astigmatism largely fell between 0.25 D and 1.25 D in these predominantly elderly female Chinese patients, and ATR astigmatism increased with age. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.
Resumo:
OBJECTIVE: To study the visual acuity and astigmatism of persons undergoing cataract extraction by local surgeons in rural China. METHODS: Visual acuity, keratometry, and refraction were measured 10 to 14 months postoperatively for all cataract cases during 4 months in Sanrao, China. RESULTS: Among 313 eligible subjects, 242 (77%) could be contacted, of whom 176 (73%) were examined. Of those who were examined, mean +/- SD age was 69.3 +/- 10.5 years, 66.5% were female, 35 had been operated on bilaterally at Sanrao, and 85.2% had a preoperative presenting visual acuity of 6/60 or worse. Presenting and best-corrected postoperative acuity in the eye that was operated on were 6/18 or better in 83.4% and 95.7%, respectively. Among 27 fellow eyes operated on elsewhere, 40.7% had a presenting acuity of 6/18 or better and 40.7% were blind (P < .001). Mean +/- SD postoperative astigmatism did not differ between 211 eyes that were operated on (-1.13 +/- 0.84 diopters) and 109 eyes that were not (-1.13 +/- 1.17 diopters; P = .27). Presence of operative complications (8.5%) and older age were associated with worse vision; bilateral surgery was associated with better vision. CONCLUSIONS: These results confirm the effectiveness of skill transfer in this setting, with superior outcomes to most studies in rural Asia and to eyes in this cohort operated on at other facilities.
Resumo:
OBJECTIVES:
To describe a modified manual cataract extraction technique, sutureless large-incision manual cataract extraction (SLIMCE), and to report its clinical outcomes.
METHODS:
Case notes of 50 consecutive patients with cataract surgery performed using the SLIMCE technique were retrospectively reviewed. Clinical outcomes 3 months after surgery were analyzed, including postoperative uncorrected visual acuity, best-corrected visual acuity, intraoperative and postoperative complications, endothelial cell loss, and surgically induced astigmatism using the vector analysis method.
RESULTS:
At the 3-month follow-up, all 50 patients had postoperative best-corrected visual acuity of at least 20/60, and 37 patients (74%) had visual acuity of at least 20/30. Uncorrected visual acuity was at least 20/68 in 28 patients (56%) and was between 20/80 and 20/200 in 22 patients (44%). No significant intraoperative complications were encountered, and sutureless wounds were achieved in all but 2 patients. At the 3-month follow-up, endothelial cell loss was 3.9%, and the mean surgically induced astigmatism was 0.69 diopter.
CONCLUSIONS:
SLIMCE is a safe and effective manual cataract extraction technique with low rates of surgically induced astigmatism and endothelial cell loss. In view of its low cost, SLIMCE may have a potential role in reducing cataract blindness in developing countries.
Resumo:
PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.
PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.
RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.
CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.
Resumo:
To estimate the prevalence of refractive error in adults across Europe. Refractive data (mean spherical equivalent) collected between 1990 and 2013 from fifteen population-based cohort and cross-sectional studies of the European Eye Epidemiology (E3) Consortium were combined in a random effects meta-analysis stratified by 5-year age intervals and gender. Participants were excluded if they were identified as having had cataract surgery, retinal detachment, refractive surgery or other factors that might influence refraction. Estimates of refractive error prevalence were obtained including the following classifications: myopia ≤−0.75 diopters (D), high myopia ≤−6D, hyperopia ≥1D and astigmatism ≥1D. Meta-analysis of refractive error was performed for 61,946 individuals from fifteen studies with median age ranging from 44 to 81 and minimal ethnic variation (98 % European ancestry). The age-standardised prevalences (using the 2010 European Standard Population, limited to those ≥25 and <90 years old) were: myopia 30.6 % [95 % confidence interval (CI) 30.4–30.9], high myopia 2.7 % (95 % CI 2.69–2.73), hyperopia 25.2 % (95 % CI 25.0–25.4) and astigmatism 23.9 % (95 % CI 23.7–24.1). Age-specific estimates revealed a high prevalence of myopia in younger participants [47.2 % (CI 41.8–52.5) in 25–29 years-olds]. Refractive error affects just over a half of European adults. The greatest burden of refractive error is due to myopia, with high prevalence rates in young adults. Using the 2010 European population estimates, we estimate there are 227.2 million people with myopia across Europe.
Resumo:
Purpose. We assessed the prevalence and predictors of inaccurate refractive error among rural refractionists in western China. Methods. A subset of primary school children with visual acuity (VA) ≤6/12 in ≥1 eye, undergoing subjective refinement by local refractionists after cycloplegic autorefraction in an ongoing population-based study, received repeat refraction by university optometrists for quality control. Results. Among 502 children (mean age 10.5 years, 53.2% girls), independent predictors of poor (inaccurate by ≥1.0 diopter [D]) refraction by 21 rural practitioners (66.7% with high school or lower education) included hyperopia (odds ratio [OR], 4.2; 95% confidence interval [CI], 2.4-7.3, P < 0.001), astigmatism (OR = 3.8; 95% CI, 2.5-5.6; P < 0.001) and VA uncorrectable to >6/12 by the rural refractionist (OR = 4.7; 95% CI, 3.1-7.3; P = < 0.001). Among 201 children whose vision was uncorrectable in ≥1 eye by the rural refractionists, vision could be improved to >6/12 by the university optometrist in 110 (54.7%). We estimate vision could be so improved in 9.1% of all children refracted by these rural refractionists. A reason for inaccuracy in this setting is the erroneous tendency of rural refractionists to adjust instrument values for accommodation, even under cycloplegia. Conclusions. Rural refractionists in western China have little formal training and frequently fail to optimize VA among children, even when autorefractors are used. Training is needed emphasizing better use of automated refraction, particularly in children with astigmatism and hyperopia. © 2014 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
OBJECTIVES: To evaluate different refractive cutoffs for spectacle provision with regards to their impact on visual improvement and spectacle compliance. DESIGN: Prospective study of visual improvement and spectacle compliance. PARTICIPANTS: South African school children aged 6-19 years receiving free spectacles in a programme supported by Helen Keller International. METHODS: Refractive error, age, gender, urban versus rural residence, presenting and best-corrected vision were recorded for participants. Spectacle wear was observed directly at an unannounced follow-up examination 4-11 months after initial provision of spectacles. The association between five proposed refractive cutoff protocols and visual improvement and spectacle compliance were examined in separate multivariate models. MAIN OUTCOMES: Refractive cutoffs for spectacle distribution which would effectively identify children with improved vision, and those more likely to comply with spectacle wear. RESULTS: Among 8520 children screened, 810 (9.5%) received spectacles, of whom 636 (79%) were aged 10-14 years, 530 (65%) were girls, 324 (40%) had vision improvement > or = 3 lines, and 483 (60%) were examined 6.4+/-1.5 (range 4.6 to 10.9) months after spectacle dispensing. Among examined children, 149 (31%) were wearing or carrying their glasses. Children meeting cutoffs < or = -0.75 D of myopia, > or = +1.00 D of hyperopia and > or = +0.75 D of astigmatism had significantly greater improvement in vision than children failing to meet these criteria, when adjusting for age, gender and urban versus rural residence. None of the proposed refractive protocols discriminated between children wearing and not wearing spectacles. Presenting vision and improvement in vision were unassociated with subsequent spectacle wear, but girls (p < or = 0.0006 for all models) were more likely to be wearing glasses than were boys. CONCLUSIONS: To the best of our knowledge, this is the first suggested refractive cutoff for glasses dispensing validated with respect to key programme outcomes. The lack of association between spectacle retention and either refractive error or vision may have been due to the relatively modest degree of refractive error in this African population.
Resumo:
PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.
Resumo:
OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Resumo:
OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.
Resumo:
PURPOSE:
To compare the outcomes of cataract surgery performed with 3 incision size-dependent phacoemulsification groups (1.8, 2.2, and 3.0 mm).
DESIGN:
Prospective randomized comparative study.
METHODS:
One hundred twenty eyes of 120 patients with age-related cataract (grades 2 to 4) were categorized according to the Lens Opacities Classification System III. Eligible subjects were randomly assigned to 3 surgical groups using coaxial phacoemulsification through 3 clear corneal incision sizes (1.8, 2.2, and 3.0 mm). Different intraoperative and postoperative outcome measures were obtained, with corneal incision size and surgically induced astigmatism as the main clinical outcomes.
RESULTS:
There were no statistically significant differences in most of the intraoperative and postoperative outcome measures among the 3 groups. However, the mean cord length of the clear corneal incision was increased in each group after surgery. The mean maximal clear corneal incision thickness in the 1.8-mm group was significantly greater than for the other groups at 1 month. The mean surgically induced astigmatism in the 1.8- and 2.2-mm groups was significantly less than that in the 3.0-mm group after 1 month, without significant difference between the 1.8- and 2.2-mm groups.
CONCLUSIONS:
With appropriate equipment, smaller incisions may result in less astigmatism, but the particular system used will influence incision stress and wound integrity, and may thus limit the reduction in incision size and astigmatism that is achievable.
Resumo:
PURPOSE: To study, for the first time, the effect of wearing ready-made glasses and glasses with power determined by self-refraction on children's quality of life. METHODS: This is a randomized, double-masked non-inferiority trial. Children in grades 7 and 8 (age 12-15 years) in nine Chinese secondary schools, with presenting visual acuity (VA) ≤6/12 improved with refraction to ≥6/7.5 bilaterally, refractive error ≤-1.0 D and <2.0 D of anisometropia and astigmatism bilaterally, were randomized to receive ready-made spectacles (RM) or identical-appearing spectacles with power determined by: subjective cycloplegic retinoscopy by a university optometrist (U), a rural refractionist (R) or non-cycloplegic self-refraction (SR). Main study outcome was global score on the National Eye Institute Refractive Error Quality of Life-42 (NEI-RQL-42) after 2 months of wearing study glasses, comparing other groups with the U group, adjusting for baseline score. RESULTS: Only one child (0.18%) was excluded for anisometropia or astigmatism. A total of 426 eligible subjects (mean age 14.2 years, 84.5% without glasses at baseline) were allocated to U [103 (24.2%)], RM [113 (26.5%)], R [108 (25.4%)] and SR [102 (23.9%)] groups, respectively. Baseline and endline score data were available for 398 (93.4%) of subjects. In multiple regression models adjusting for baseline score, older age (p = 0.003) and baseline spectacle wear (p = 0.016), but not study group assignment, were significantly associated with lower final score. CONCLUSION: Quality of life wearing ready-mades or glasses based on self-refraction did not differ from that with cycloplegic refraction by an experienced optometrist in this non-inferiority trial.