143 resultados para URINE SAMPLES

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The illegal use of anabolic substances in the meat producing industry is an ongoing problem due to the continual production of new synthetic compounds and/or the practice of low-level cocktail administration to avoid detection by the surveillance schemes of EU member states National Plan surveillance systems.

We present a highly sensitive reporter gene assay and sample extraction procedure based on a two step solid phase extraction and high performance liquid chromatography, developed for the detection of glucocorticoid abuse in bovine urine. The assay is capable of detecting compounds with glucocorticoid bioactivity and is extremely sensitive with an EC50 of 0.79 ng mL-1 for dexamethasone. New or unknown compounds with glucocorticoid bioactivity and low-level cocktail mixtures are detectable by this assay.

Cross-reactivity data for a range of 11ß-hydroxyglucocorticoids has been provided. This assay shows low interference from the 11-keto prohormones and other steroidal hormones. The assay may be suitable for application in other matrices such as hair. In conclusion this screening assay offers advantages over existing analytical techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Efficient control of the illegal use of anabolic steroids must both take into account metabolic patterns and associated kinetics of elimination; in this context, an extensive animal experiment involving 24 calves and consisting of three administrations of 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate esters was carried out over 50 days. Urine samples were regularly collected during the experiment from all treated and non-treated calves. For sample preparation, a single step high throughput protocol based on 96-well C-18 SPE was developed and validated according to the European Decision 2002/657/EC requirements. Decision limits (CC alpha) for steroids were below 0.1 mu g L-1, except for 19-norandrosterone (CC alpha = 0.7 mu g L-1) and estrone (CC alpha = 0.3 mu g L-1). Kinetics of elimination of the administered 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate were established by monitoring 17 beta-estradiol, 17 alpha-estradiol, estrone and 17 beta-nandrolone, 17 alpha-nandrolone, 19-noretiocholanolone, 19-norandrostenedione, respectively. All animals demonstrated homogeneous patterns of elimination both from a qualitative (metabolite profile) and quantitative point of view (elimination kinetics in urine). Most abundant metabolites were 17 alpha-estradiol and 17 alpha-nandrolone (> 20 and 2 mg L-1, respectively after 17 beta-estradiol 3-benzoate and 17 beta-nandrolone laureate administration) whereas 17 beta-estradiol, estrone, 17 beta-nandrolone, 19-noretiocholanolone and 19-norandrostenedione were found as secondary metabolites at concentration values up to the mu g L-1 level. No significant difference was observed between male and female animals. The effect of several consecutive injections on elimination profiles was studied and revealed a tendency toward a decrease in the biotransformation of administered steroid 17 beta form. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sensitive and specific urinary biomarkers can improve patient outcomes in many diseases through informing early diagnosis. Unfortunately, to date, the accuracy and translation of diagnostic urinary biomarkers into clinical practice has been disappointing. We believe this may be due to inappropriate standardization of diagnostic urinary biomarkers. Our objective was therefore to characterize the effects of standardizing urinary levels of IL-6, IL-8, and VEGF using the commonly applied standards namely urinary creatinine, osmolarity and protein. First, we report results based on the biomarker levels measured in 120 hematuric patients, 80 with pathologically confirmed bladder cancer, 27 with confounding pathologies and 13 in whom no underlying cause for their hematuria was identified, designated “no diagnosis”. Protein levels were related to final diagnostic categories (p = 0.022, ANOVA). Osmolarity (mean = 529 mOsm; median = 528 mOsm) was normally distributed, while creatinine (mean = 10163 µmol/l, median = 9350 µmol/l) and protein (0.3297, 0.1155 mg/ml) distributions were not. When we compared AUROCs for IL-6, IL-8 and VEGF levels, we found that protein standardized levels consistently resulted in the lowest AUROCs. The latter suggests that protein standardization attenuates the “true” differences in biomarker levels across controls and bladder cancer samples. Second, in 72 hematuric patients; 48 bladder cancer and 24 controls, in whom urine samples had been collected on recruitment and at follow-up (median = 11 (1 to 20 months)), we demonstrate that protein levels were approximately 24% lower at follow-up (Bland Altman plots). There was an association between differences in individual biomarkers and differences in protein levels over time, particularly in control patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The performances of four LC-MS/MS methodologies for determination of up to eight mycotoxin biomarkers in human urines were compared by involving three laboratories that analysed common urine samples spiked at two levels of each biomarker. Each laboratory received a calibration solution, spiked urines and the corresponding unspiked urine. The two spiking levels for each biomarker were chosen by considering the levels naturally occurring in human urines and the limits of quantification of the LC-MS/MS methodologies used by the participating laboratories. The results of each laboratory were evaluated for their z-score values. The percentage of satisfactory z-scores (vertical bar z vertical bar 2) were obtained for fumonisin B-1 (7/12 results), ochratoxin A (4/8 results) and alpha-zearalenol (1/8 results). The percentage of satisfactory z-scores for fumonisin B-1 and ochratoxin A increased from 42 to 83% for fumonisin B-1 and from 50 to 62% for ochratoxin A when laboratories 1 and 2 used own calibrants. Factors that could explain the different results obtained for fumonisin B-1 and ochratoxin A with provided and own calibration solutions could not be identified in this study and should be carefully investigated in future studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of cortisol levels as a measure of stress is often complicated by the use of invasive techniques that may increase hypothalamic-pituitary-adrenal (HPA) axis activity during sample collection. The goal of this study was to collect samples noninvasively and validate an enzyme-immunoassay (EIA) for the measurement of cortisol in urine to quantify HPA axis activity in the bearded emperor tamarin (Saguinus imperator subgrisescens). Urine samples were collected from trained subjects between 0700 and 0730 hr during a 1-month period, and were pooled for immunological validation. We validated the assay immunologically by demonstrating specificity, accuracy, precision, and sensitivity. For biological validation of the assay, we showed that levels of urinary cortisol (in samples collected between 0700 and 1700 hr) varied significantly across the day. Cortisol concentration was lowest at 0700 hr, increased to a mid-morning peak (0900 hr), and declined across the remainder of the day in a typical mammalian circadian pattern. We thus demonstrate that urinary cortisol can be used to quantify HPA activity in S. i. subgrisescens. (C) 2004 Wiley-Liss, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple dry chemistry time-resolved fluorescence immunoassay (TR-FIA) method was developed for the measurement of zeranol in bovine urine samples. The samples were purified by immunoaffinity chromatography and a specificity-enhanced zeranol antibody was employed in the immunoassay. This resulted in a highly selective method, which had only negligible reactivity with Fusarium spp, toxins. The all-in-one-well dry chemistry concept made the assay very simple to use because all the assay-specific reagents were already present in the reaction wells in dry form. Only the addition of diluted sample extract was required to perform the competitive one-step TR-FIA and the results were available in less than 1 h. The analytical limit of detection (mean + 3s) for the immunoassay was 0.16 ng ml(-1) (n=12) and the functional limit of detection for the whole method, estimated by the analysis of zeranol-free samples, was 1.3 ng ml(-1) (n=20). The recovery of zeranol at the level of 2 ng ml(-1) was 99% (n=18) and the within-assay variation ranged between 4.5 and 9.0%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ractopamine (RCT) is a phenethanolamine member of the family of beta-adrenergic agonists (beta-agonists), This class of compounds have become notable for their properties of enhancing the growth rates of farm animal species but are not licensed for use in Europe. An ELISA procedure employing a polyclonal antibody raised in a goat was developed to detect RCT residues in bovine urine samples, The assay had a high sensitivity (calibration curve mid-point of 22 pg per well), allowing the analysis of urine samples without the need for sample clean-up. In addition, an LC-MS-MS confirmatory procedure was developed which was able to act as a confirmatory procedure for the ELISA results. Four calves were orally treated with RCT (0.1 mg kg(-1) body mass for 17 d) and urine samples collected were assayed by both analytical procedures. It was observed that RCT residues were excreted mainly in the form of glucuronides and deconjugation could be achieved using two different sources of the enzyme beta-glucuronidase (Helix pomatia and Escherichia coli), High concentrations of RCT residues were found throughout the medication period (44-473 ng ml(-1); LC-MS-MS data) and remained present for several days following removal of the drug from the diet, RCT residues were no longer detectable 2 weeks after withdrawal, Good agreement (r(2) = 0.73) was achieved between the ELISA and LC-MS-MS results, especially when sample deconjugation was applied to the urine samples for both sets of analyses, The results show that an effective screening and confirmatory system was devised to detect RCT residues in urine samples taken during treatment and close to withdrawal, However, alternative matrices may have to be selected to allow the illegal use of the substance to be detected following prolonged withdrawal times.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Immunoaffinity chromatography (IAC) and affinity chromatography (AC:) are widely used for extraction of drugs from biological samples. Fifteen column types were purchased from five different manufacturers and;their ability to bind specific drugs including beta-agonists and anabolic steroids over a range of analyte concentrations in fortified bovine urine samples was assessed. The performance data obtained from these columns were compared with columns produced in this laboratory (in house columns). The in house columns gave the highest recoveries, ranging from 92 to 100% at the 1 ng spiking concentration, for five of the seven analytes assessed. Forty percent (11 of 27) of all the commercial column assessments recorded recoveries of less than 50% even when the lowest spiking concentration was applied (1 ng). For one manufacturer, only one of seven different columns purchased delivered extraction efficiencies greater than 50%. The extraction efficiencies of the clenbuterol columns were the highest with all commercially prepared columns showing at least 50% binding of radiolabelled tracer. Recoveries of alpha-nortestosterone were the lowest. The variability of these products with respect to quality control requires constant monitoring.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Many zeranol immunoassay test kits cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the evaluation and application of recently published, dry reagent time-resolved fluoroimmunoassays (TR-FIA) for zeranol and the toxin alpha-zearalenol. A ring test of bovine urine fortified with zeranol and/or alpha-zearalenol in four European Union National Reference Laboratories demonstrated that the TR-FIA tests were accurate and robust. The alpha-zearalenol TR-FIA satisfactorily quantified alpha-zearalenol in urine fortified at 10-30 ng ml(-1) . The specificity-enhanced zeranol TR-FIA accurately quantified zeranol in the range 2-5 ng ml(-1) and gave no false-positive results in blank urine, even in the presence of 30 ng ml(-1) alpha-zearalenol. Zeranol TR-FIA specificity was demonstrated further by analysing incurred zeranol-free urine samples containing natural Fusarium spp. toxins. The TR-FIA yielded no false-positive results in the presence of up to 22 ng ml(-1) toxins. The performance of four commercially available zeranol immunoassay test kits was more variable. Three kits produced many false-positive results. One kit produced only one potential false-positive using a protocol that was longer than that of the TR-FIA. These TR-FIAs will be valuable tools to develop inspection criteria to distinguish illegal zeranol abuse from contamination arising from in vivo metabolism of Fusarium spp. toxins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The consumption of maize highly contaminated with carcinogenic fumonisins has been linked to high oesophageal cancer rates. The aim of this study was to validate a urinary fumonisin B-1 (UFB1) biomarker as a measure of fumonisin exposure and to investigate the reduction in exposure following a simple and culturally acceptable intervention.

Methods: At baseline home-grown maize, maize-based porridge, and first-void urine samples were collected from female participants (n = 22), following their traditional food practices in Centane, South Africa. During intervention the participants were trained to recognize and remove visibly infected kernels, and to wash the remaining kernels. Participants consumed the porridge prepared from the sorted and washed maize on each day of the two-day intervention. Porridge, maize, and urine samples were collected for FB1 analyses.

Results: The geometric mean (95% confidence interval) for FB1 exposure based on porridge (dry weight) consumption at baseline and following intervention was 4.84 (2.87-8.14) and 1.87 (1.40-2.51) mg FB1/kg body weight/day, respectively, (62% reduction, P < 0.05). UFB1C, UFB1 normalized for creatinine, was reduced from 470 (295-750) at baseline to 279 (202-386) pg/mg creatinine following intervention (41% reduction, P = 0.06). The UFB1C biomarker was positively correlated with FB1 intake at the individual level (r - 0.4972, P < 0.01). Urinary excretion of FB1 was estimated to be 0.075% (0.054%-0.104%) of the FB1 intake.

Conclusion: UFB1 reflects individual FB1 exposure and thus represents a valuable biomarker for future fumonisin risk assessment.

Impact: The simple intervention method, hand sorting and washing, could positively impact on food safety and health in communities exposed to fumonisins. Cancer Epidemiol Biomarkers Prev; 20(3); 483-9. (C)2011 AACR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fumonisins are mycotoxins produced by Fusarium spp. and commonly contaminate maize and maize products worldwide. Fumonisins are rodent carcinogens and have been associated with human esophageal cancer. However, the lack of a valid exposure biomarker has hindered both the assessment of human exposure and the evaluation of disease risk. A sensitive liquid chromatography-mass spectrometry method to measure urinary fumonisin B1 (FB1) following extraction on Oasis MAX cartridges was established and applied to urine samples from women in a cohort recruited in Morelos County, Mexico. Urinary FB1 was compared with dietary information on tortilla consumption. FB1 recovery in spiked samples averaged 94% as judged by deuterium-labeled FB1 internal standard. Urinary FB1 was determined in 75 samples from women selected based on low, medium, or high consumption of maize-based tortillas. The geometric mean (95% confidence interval) of urinary FB1 was 35.0 (18.8-65.2), 63.1 (36.8-108.2), and 147.4 (87.6-248.0) pg/mL and the frequency of samples above the detection limit (set at 20 pg FB1/mL urine) was 45%, 80%, and 96% for the low, medium, and high groups, respectively. Women with high intake had a 3-fold higher average FB1 levels compared with the "low intake" group (F = 7.3; P = 0.0015). Urinary FB1 was correlated with maize intake (P-trend = 0.001); the correlation remained significant after adjusting for age, education, and place of residence. This study suggests that measurement of urinary FB1 is sufficiently sensitive for fumonisin exposure assessment in human populations and could be a valuable tool in investigating the associated health effects of exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Deoxynivalenol (DON) is a toxic fungal metabolite that frequently contaminates cereal crops. DON is toxic to animals, but the effects on humans are poorly understood, in part because exposure estimates are of limited precision.

OBJECTIVES: In this study we used the U.K. adult National Diet and Nutrition Survey to compare 24-hr urinary DON excretion with cereal intake.

METHODS: One hundred subjects were identified for each of the following cereal consumption groups: low (mean, 107 g cereal/day; range, 88-125), medium (mean, 179 g/day; range, 162-195) and high (mean, 300 g/day, range, 276-325). DON was analyzed in 24-hr urine samples by liquid chromatography mass spectrometry after purification on immunoaffinity columns.

RESULTS: DON was detected in 296 of 300 (98.7%) urine samples. Cereal intake was significantly associated with urinary DON (P < 0.0005), with the geometric mean urinary levels being 6.55 mu g DON/day [95% confidence interval (CI), 5.71-7-531; 9.63 mu g/day (95% Cl, 8.39-11.05); and 13.24 mu g/day (95% Cl, 11.54-15.19) for low-, medium-, and high-intake groups, respectively. In multivariable analysis, wholemeal bread (p < 0.0005), white bread (p < 0.0005), "other" bread (p < 0.0005), buns/cakes (p = 0.003), high-fiber breakfast cereal (p = 0.016), and pasta (p = 0.017) were significantly associated with urinary DON. Wholemeal bread was associated with the greatest percent increase in urinary DON per unit of consumption, but white bread contributed approximately twice as much as wholemeal bread to the urinary DON levels because it was consumed in higher amounts.

CONCLUSION: The majority of adults in the United Kingdom appear to be exposed to DON, and on the basis of the urinary levels, we estimate that some individuals may exceed the European Union (EU) recommended maximum tolerable daily intake of 1,000 ng DON/kg (bw). This exposure biomarker will be a valuable toot for biomonitoring as part of surveillance strategies and in etiologic studies of DON and human disease risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Toasting friends and family with realgar wines and painting children's foreheads and limbs with the leftover realgar/alcohol slurries is an important customary ritual during the Dragon Boat Festival (DBF); a Chinese national holiday and ancient feast day celebrated throughout Asia. Realgar is an arsenic sulfide mineral, and source of highly toxic inorganic arsenic. Despite the long history of realgar use during the DBF, associated risk to human health by arsenic ingestion or percutaneous adsorption is unknown. To address this urine samples were collected from a cohort of volunteers who were partaking in the DBF festivities. The total concentration of arsenic in the wine consumed was 70 mg L(-1) with all the arsenic found to be inorganic. Total arsenic concentrations in adult urine reached a maximum of ca. 550 mu g L(-1) (mean 220.2 mu g L(-1)) after 16 h post-ingestion of realgar wine, while face painting caused arsenic levels in children's urine to soar to 100 mu g L(-1) (mean 85.3 mu g L(-1)) 40 h after the initial paint application. The average concentration of inorganic arsenic in the urine of realgar wine drinkers on average doubled 16 h after drinking, although this was not permanent and levels subsided after 28 h. As would be expected in young children, the proportions of organic arsenic in the urine remained high throughout the 88-h monitoring period. However, even when arsenic concentrations in the urine peaked at 40 h after paint application, concentrations in the urine only declined slightly thereafter, suggesting pronounced longer term dermal accumulation and penetration of arsenic. Drinking wines blended with realgar or using realgar based paints on children does result in the significant absorption of arsenic and therefore presents a potentially serious and currently unquantified health risk. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Acute lung injury (ALI) is a common devastating clinical syndrome characterized by life-threatening respiratory failure requiring mechanical ventilation and multiple organ failure. There are in vitro, animal studies and pre-clinical data suggesting that statins may be beneficial in ALI. The Hydroxymethylglutaryl-CoA reductase inhibition with simvastatin in Acute lung injury to Reduce Pulmonary dysfunction (HARP-2) trial is a multicenter, prospective, randomized, allocation concealed, double-blind, placebo-controlled clinical trial which aims to test the hypothesis that treatment with simvastatin will improve clinical outcomes in patients with ALI.

Methods/Design: Patients fulfilling the American-European Consensus Conference Definition of ALI will be randomized in a 1: 1 ratio to receive enteral simvastatin 80 mg or placebo once daily for a maximum of 28 days. Allocation to randomized groups will be stratified with respect to hospital of recruitment and vasopressor requirement. Data will be recorded by participating ICUs until hospital discharge, and surviving patients will be followed up by post at 3, 6 and 12 months post randomization. The primary outcome is number of ventilator-free days to day 28. Secondary outcomes are: change in oxygenation index and sequential organ failure assessment score up to day 28, number of non pulmonary organ failure free days to day 28, critical care unit mortality; hospital mortality; 28 day post randomization mortality and 12 month post randomization mortality; health related quality of life at discharge, 3, 6 and 12 months post randomization; length of critical care unit and hospital stay; health service use up to 12 months post-randomization; and safety. A total of 540 patients will be recruited from approximately 35 ICUs in the UK and Ireland. An economic evaluation will be conducted alongside the trial. Plasma and urine samples will be taken up to day 28 to investigate potential mechanisms by which simvastatin might act to improve clinical outcomes.